2,821 research outputs found
Back-to-back azimuthal correlations in Z+jet events at high transverse momentum in the TMD parton branching method at next-to-leading order
Azimuthal correlations in Z+jet production at large transverse momenta are
computed by matching Parton - Branching (PB) TMD parton distributions and
showers with NLO calculations via MCatNLO. The predictions are compared with
those for dijet production in the same kinematic range. The azimuthal
correlations between the Z boson and the leading jet are steeper
compared to those in dijet production at transverse momenta GeV
, while they become similar for very high transverse momenta
GeV. The different patterns of Z+jet and dijet azimuthal correlations can be
used to search for potential factorization - breaking effects in the
back-to-back region, which depend on the different color and spin structure of
the final states and their interferences with the initial states. In order to
investigate these effects experimentally, we propose to measure the ratio of
the distributions in for Z+jet - and multijet production at low
and at high transverse momenta, and compare the results to predictions obtained
assuming factorization. We examine the role of theoretical uncertainties by
performing variations of the factorization scale, renormalization scale and
matching scale. In particular, we present a comparative study of matching scale
uncertainties in the cases of PB -TMD and collinear parton showers
El correo electrónico en la consulta de Parkinson: ¿soluciones a un clic? // Use of e-mail for Parkinson's disease consultations: Are answers just a clic away?
INTRODUCCION: La problemática de los trastornos del movimiento (TM) es compleja y la duración y frecuencia de las consultas presenciales puede estar limitada por problemas de espacio y tiempo. Analizamos el funcionamiento de un servicio de atención por correo electrónico institucional para médicos de Atención Primaria (MAP) y pacientes en la Unidad de Trastornos del Movimiento (UTM).
METODOS: Se revisaron retrospectivamente los correos electrónicos enviados y recibidos en un periodo de 4 meses, un año tras su implantación. La dirección se proporcionaba en consulta y mediante sesiones informativas a los MAP del área. Se analizaron datos clínicos y demográficos de los pacientes, tipo de interlocutor, número de consultas, motivo y actuaciones derivadas de ellas.
RESULTADOS: Del 1 de enero al 30 de abril de 2015 se recibieron 137 correos de 63 pacientes (43% varones; edad 71 ± 10,5 años) diagnosticados de enfermedad de Parkinson (76%), parkinsonismos atípicos (10%) y otros (14%), y se enviaron 116 respuestas. En 20 casos (32%) fueron redactados por el paciente, en 38 (60%) por sus familiares y en 5 (8%) por MAP. Los motivos de consulta fueron clínicos en 50 casos (80%): deterioro clínico (16; 32%), nuevos síntomas (14; 28%), efectos secundarios o dudas sobre medicación (20; 40%). Como consecuencia, se adelantó una cita programada en 9 casos (14%), mientras que el resto se solucionaron por correo electrónico. En 13 (20%), el motivo de consulta fue burocrático: relacionado con citas (11, 85%) y solicitud de informe (2, 15%). La satisfacción fue generalizada, sin constituir una sobrecarga asistencial excesiva para los facultativos responsables.
CONCLUSIONES: La implantación de una consulta por correo electrónico es factible en UTM, facilita la comunicación médico-paciente y la continuidad asistencial con Atención Primaria. //
INTRODUCTION: The clinical problems of patients with movement disorders (MD) are complex, and the duration and frequency of face-to-face consultations may be insufficient to meet their needs. We analysed the implementation of an e-mail-based query service for our MD unit's patients and their primary care physicians (PCPs).
METHODS: We retrospectively reviewed all consecutive emails sent and received over a period of 4 months, one year after implementation of the e-mail inquiry system. All patients received the during consultations, and PCPs, during scheduled informative meetings. We recorded and later analysed the profile of the questioner, patients’ demographic and clinical data, number of queries, reason for consultation, and actions taken.
RESULTS: From 1 January 2015 to 30 April 2015, the service received 137 emails from 63 patients (43% male, mean age 71 ± 10.5) diagnosed with Parkinson's disease (76%), atypical parkinsonism (10%), and others (14%); 116 responses were sent. Twenty (32%) emails were written by patients, 38 (60%) by their caregivers, and 5 (8%) by their PCPs. The reasons for consultation were clinical in 50 cases (80%): 16 (32%) described clinical deterioration, 14 (28%) onset of new symptoms, and 20 (40%) side effects or concerns about medications. In 13 cases (20%), the query was bureaucratic: 11 were related to appointments (85%) and 2 were requests for clinical reports (15%). In response, new appointments were scheduled in 9 cases (14%), while the rest of the questions were answered by email. Patients were satisfied overall and the additional care burden on specialists was not excessive.
CONCLUSIONS: Implementing an e-mail-based consultation system is feasible in MD units. It facilitates both communication between neurologists and patients and continued care in the primary care setting
DualSPHysics: from fluid dynamics to multiphysics problems
DualSPHysics is a weakly compressible smoothed particle hydrodynamics (SPH) Navier–Stokes solver initially conceived to deal with coastal engineering problems, especially those related to wave impact with coastal structures. Since the first release back in 2011, DualSPHysics has shown to be robust and accurate for simulating extreme wave events along with a continuous improvement in efficiency thanks to the exploitation of hardware such as graphics processing units for scientific computing or the coupling with wave propagating models such as SWASH and OceanWave3D. Numerous additional functionalities have also been included in the DualSPHysics package over the last few years which allow the simulation of fluid-driven objects. The use of the discrete element method has allowed the solver to simulate the interaction among different bodies (sliding rocks, for example), which provides a unique tool to analyse debris flows. In addition, the recent coupling with other solvers like Project Chrono or MoorDyn has been a milestone in the development of the solver. Project Chrono allows the simulation of articulated structures with joints, hinges, sliders and springs and MoorDyn allows simulating moored structures. Both functionalities make DualSPHysics especially suited for the simulation of offshore energy harvesting devices. Lately, the present state of maturity of the solver goes beyond single-phase simulations, allowing multi-phase simulations with gas–liquid and a combination of Newtonian and non-Newtonian models expanding further the capabilities and range of applications for the DualSPHysics solver. These advances and functionalities make DualSPHysics an advanced meshless solver with emphasis on free-surface flow modelling
A Cytoplasmic Domain Mutation in ClC-Kb Affects Long-Distance Communication Across the Membrane
BACKGROUND: ClC-Kb and ClC-Ka are homologous chloride channels that facilitate chloride homeostasis in the kidney and inner ear. Disruption of ClC-Kb leads to Bartter's Syndrome, a kidney disease. A point mutation in ClC-Kb, R538P, linked to Bartter's Syndrome and located in the C-terminal cytoplasmic domain was hypothesized to alter electrophysiological properties due to its proximity to an important membrane-embedded helix. METHODOLOGY/PRINCIPAL FINDINGS: Two-electrode voltage clamp experiments were used to examine the electrophysiological properties of the mutation R538P in both ClC-Kb and ClC-Ka. R538P selectively abolishes extracellular calcium activation of ClC-Kb but not ClC-Ka. In attempting to determine the reason for this specificity, we hypothesized that the ClC-Kb C-terminal domain had either a different oligomeric status or dimerization interface than that of ClC-Ka, for which a crystal structure has been published. We purified a recombinant protein corresponding to the ClC-Kb C-terminal domain and used multi-angle light scattering together with a cysteine-crosslinking approach to show that the dimerization interface is conserved between the ClC-Kb and ClC-Ka C-terminal domains, despite the fact that there are several differences in the amino acids that occur at this interface. CONCLUSIONS: The R538P mutation in ClC-Kb, which leads to Bartter's Syndrome, abolishes calcium activation of the channel. This suggests that a significant conformational change--ranging from the cytoplasmic side of the protein to the extracellular side of the protein--is involved in the Ca(2+)-activation process for ClC-Kb, and shows that the cytoplasmic domain is important for the channel's electrophysiological properties. In the highly similar ClC-Ka (90% identical), the R538P mutation does not affect activation by extracellular Ca(2+). This selective outcome indicates that ClC-Ka and ClC-Kb differ in how conformational changes are translated to the extracellular domain, despite the fact that the cytoplasmic domains share the same quaternary structure
Combined clinical and genomic signatures for the prognosis of early stage non-small cell lung cancer based on gene copy number alterations
BACKGROUND: The development of a more refined prognostic methodology for early non-small cell lung cancer (NSCLC) is an unmet clinical need. An accurate prognostic tool might help to select patients at early stages for adjuvant therapies. RESULTS: A new integrated bioinformatics searching strategy, that combines gene copy number alterations and expression, together with clinical parameters was applied to derive two prognostic genomic signatures. The proposed methodology combines data from patients with and without clinical data with a priori information on the ability of a gene to be a prognostic marker. Two initial candidate sets of 513 and 150 genes for lung adenocarcinoma (ADC) and squamous cell carcinoma (SCC), respectively, were generated by identifying genes which have both: a) significant correlation between copy number and gene expression, and b) significant prognostic value at the gene expression level in external databases. From these candidates, two panels of 7 (ADC) and 5 (SCC) genes were further identified via semi-supervised learning. These panels, together with clinical data (stage, age and sex), were used to construct the ADC and SCC hazard scores combining clinical and genomic data. The signatures were validated in two independent datasets (n = 73 for ADC, n = 97 for SCC), confirming that the prognostic value of both clinical-genomic models is robust, statistically significant (P = 0.008 for ADC and P = 0.019 for SCC) and outperforms both the clinical models (P = 0.060 for ADC and P = 0.121 for SCC) and the genomic models applied separately (P = 0.350 for ADC and P = 0.269 for SCC). CONCLUSION: The present work provides a methodology to generate a robust signature using copy number data that can be potentially used to any cancer. Using it, we found new prognostic scores based on tumor DNA that, jointly with clinical information, are able to predict overall survival (OS) in patients with early-stage ADC and SCC
Constraints on the χ_(c1) versus χ_(c2) polarizations in proton-proton collisions at √s = 8 TeV
The polarizations of promptly produced χ_(c1) and χ_(c2) mesons are studied using data collected by the CMS experiment at the LHC, in proton-proton collisions at √s=8 TeV. The χ_c states are reconstructed via their radiative decays χ_c → J/ψγ, with the photons being measured through conversions to e⁺e⁻, which allows the two states to be well resolved. The polarizations are measured in the helicity frame, through the analysis of the χ_(c2) to χ_(c1) yield ratio as a function of the polar or azimuthal angle of the positive muon emitted in the J/ψ → μ⁺μ⁻ decay, in three bins of J/ψ transverse momentum. While no differences are seen between the two states in terms of azimuthal decay angle distributions, they are observed to have significantly different polar anisotropies. The measurement favors a scenario where at least one of the two states is strongly polarized along the helicity quantization axis, in agreement with nonrelativistic quantum chromodynamics predictions. This is the first measurement of significantly polarized quarkonia produced at high transverse momentum
Total absorption spectroscopy study of the beta decay of Br-86 and Rb-91
The beta decays of Br-86 and Rb-91 have been studied using the total absorption spectroscopy technique. The radioactive nuclei were produced at the Ion Guide Isotope Separator On-Line facility in Jyvaskyla and further purified using the JYFLTRAP. Br-86 and Rb-91 are considered to be major contributors to the decay heat in reactors. In addition, Rb-91 was used as a normalization point in direct measurements of mean gamma energies released in the beta decay of fission products by Rudstam et al. assuming that this decaywas well known from high-resolution measurements. Our results show that both decays were suffering from the Pandemonium effect and that the results of Rudstam et al. should be renormalized. The relative impact of the studied decays in the prediction of the decay heat and antineutrino spectrum from reactors has been evaluated.Peer reviewe
TMDlib2 and TMDplotter: a platform for 3D hadron structure studies
A common library, TMDlib2, for Transverse-Momentum-Dependent distributions (TMDs) and unintegrated parton distributions (uPDFs) is described, which allows for easy access of commonly used TMDs and uPDFs, providing a three-dimensional (3D) picture of the partonic structure of hadrons. The tool TMDplotter allows for web-based plotting of distributions implemented in TMDlib2, together with collinear pdfs as available in LHAPDF
Measurement of the cross-section and charge asymmetry of bosons produced in proton-proton collisions at TeV with the ATLAS detector
This paper presents measurements of the and cross-sections and the associated charge asymmetry as a
function of the absolute pseudorapidity of the decay muon. The data were
collected in proton--proton collisions at a centre-of-mass energy of 8 TeV with
the ATLAS experiment at the LHC and correspond to a total integrated luminosity
of 20.2~\mbox{fb^{-1}}. The precision of the cross-section measurements
varies between 0.8% to 1.5% as a function of the pseudorapidity, excluding the
1.9% uncertainty on the integrated luminosity. The charge asymmetry is measured
with an uncertainty between 0.002 and 0.003. The results are compared with
predictions based on next-to-next-to-leading-order calculations with various
parton distribution functions and have the sensitivity to discriminate between
them.Comment: 38 pages in total, author list starting page 22, 5 figures, 4 tables,
submitted to EPJC. All figures including auxiliary figures are available at
https://atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/STDM-2017-13
- …