2,586 research outputs found

    Fibre types in skeletal muscles of chronic obstructive pulmonary disease patients related to respiratory function and exercise tolerance.

    Get PDF
    Abstract This study aimed to investigate the relationship between skeletal muscle, fibre type composition, functional respiratory impairment and exercise tolerance in patients with moderate to severe chronic obstructive pulmonary disease (COPD). A group of 22 COPD patients and 10 healthy control subjects were studied. In COPD patients, vital capacity (VC) and forced expiratory volume in one second (FEV1) were reduced to 79% and 51%, respectively. Diffusion indices (transfer factor of the lung for carbon monoxide (TL,CO) and carbon monoxide transfer coefficient (KCO)) were also reduced. Arterial oxygen tension (Pa,O2) was normal or slightly altered. A maximal exercise test was performed and anaerobic threshold was calculated. Muscle samples from vastus lateralis were obtained by needle biopsy. Myosin heavy chain (MHC) and light chain (MLC) isoforms were separated by gel electrophoresis and quantified by densitometry. MHC isoforms were considered as molecular markers of fibre types. The proportion of the fast MHC-2B isoform was increased in COPD patients. TL,CO, KCO, VC and FEV1 were positively correlated with slow MHC isoform content. TL,CO and KCO were also negatively correlated with the content of the fast MHC-2B isoform. No correlation was found between exercise parameters and MHC isoform composition. The co-ordinated expression between MHC and MLC isoforms was altered in COPD patients. We conclude that reduced oxygen availability, probably in combination with muscle disuse, may determine muscle alterations in chronic obstructive pulmonary disease patients. The altered correlations between myosin heavy chain and light chain isoforms suggest that co-ordinated protein expression is lost in chronic obstructive pulmonary disease muscles

    Termómetros Clínicos

    Get PDF
    Na prática clínica, várias decisões relacionadas com o diagnóstico e tratamento resultam da análise dos valores da temperatura corporal, sendo a medição deste parâmetro habitualmente realizada com instrumentos de medição, designados por termómetros clínicos. A correta medição da temperatura corporal assume relevância na prática diária dos cuidados de saúde, sendo um parâmetro regularmente avaliado no diagnóstico e monitorização do estado de saúde de um indivíduo.info:eu-repo/semantics/publishedVersio

    Instrumentos de Medição da Pressão Arterial

    Get PDF
    No setor da saúde, as medições e os instrumentos de medição desempenham um papel fundamental no quotidiano dos cidadãos. Variadíssimas decisões clínicas são fundamentadas por resultados de medições, e suportadas na evidência dos mesmos. Por razões de diversa índole, os resultados obtidos a partir de sistemas de medição podem apresentar variabilidade que conduzem a erros de diagnóstico e de tratamento, comprometendo o rigor da medição e os recursos disponíveis. Neste contexto, o presente trabalho tem como finalidade divulgar conceitos gerais e específicos, aplicados a instrumentos e sistemas de medição, apresentando-se como um documento de consulta e um guia para a implementação de boas práticas no âmbito da Metrologia na Saúde.info:eu-repo/semantics/publishedVersio

    Selective high frequency mechanical actuation driven by the VO2 electronic instability

    Get PDF
    Micro- and nano-electromechanical resonators are a fundamental building block of modern technology, used in environmental monitoring, robotics, medical tools as well as fundamental science. These devices rely on dedicated electronics to generate their driving signal, resulting in an increased complexity and size. Here, we present a new paradigm to achieve high-frequency mechanical actuation based on the metal-insulator transition of VO2\mathrm{_2}, where the steep variation of its electronic properties enables to realize high-frequency electrical oscillations. The dual nature of this phase change, which is both electronic and structural, turns the electrical oscillations into an intrinsic actuation mechanism, powered by a small DC voltage and capable to selectively excite the different mechanical modes of a microstructure. Our results pave the way towards the realization of micro- and nano-electro-mechanical systems with autonomous actuation from integrated DC power sources such as solar cells or micro-batteries.Comment: Main text: 6 pages, 4 figures Supplemental Material: 16 pages, 7 section

    Fluorescent nanoparticles for sensing

    Full text link
    Nanoparticle-based fluorescent sensors have emerged as a competitive alternative to small molecule sensors, due to their excellent fluorescence-based sensing capabilities. The tailorability of design, architecture, and photophysical properties has attracted the attention of many research groups, resulting in numerous reports related to novel nanosensors applied in sensing a vast variety of biological analytes. Although semiconducting quantum dots have been the best-known representative of fluorescent nanoparticles for a long time, the increasing popularity of new classes of organic nanoparticle-based sensors, such as carbon dots and polymeric nanoparticles, is due to their biocompatibility, ease of synthesis, and biofunctionalization capabilities. For instance, fluorescent gold and silver nanoclusters have emerged as a less cytotoxic replacement for semiconducting quantum dot sensors. This chapter provides an overview of recent developments in nanoparticle-based sensors for chemical and biological sensing and includes a discussion on unique properties of nanoparticles of different composition, along with their basic mechanism of fluorescence, route of synthesis, and their advantages and limitations

    2019 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations : summary from the basic life support; advanced life support; pediatric life support; neonatal life support; education, implementation, and teams; and first aid task forces

    No full text
    The International Liaison Committee on Resuscitation has initiated a continuous review of new, peer-reviewed, published cardiopulmonary resuscitation science. This is the third annual summary of the International Liaison Committee on Resuscitation International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. It addresses the most recent published resuscitation evidence reviewed by International Liaison Committee on Resuscitation Task Force science experts. This summary addresses the role of cardiac arrest centers and dispatcher-assisted cardiopulmonary resuscitation, the role of extracorporeal cardiopulmonary resuscitation in adults and children, vasopressors in adults, advanced airway interventions in adults and children, targeted temperature management in children after cardiac arrest, initial oxygen concentration during resuscitation of newborns, and interventions for presyncope by first aid providers. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the certainty of the evidence on the basis of the Grading of Recommendations, Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations. Insights into the deliberations of the task forces are provided in the Justification and Evidence to Decision Framework Highlights sections. The task forces also listed priority knowledge gaps for further research

    Electrical behavior of MIS devices based on Si nanoclusters embedded in SiOxNy and SiO2 films

    Get PDF
    We examined and compared the electrical properties of silica (SiO2) and silicon oxynitride (SiOxNy) layers embedding silicon nanoclusters (Sinc) integrated in metal-insulator-semiconductor (MIS) devices. The technique used for the deposition of such layers is the reactive magnetron sputtering of a pure SiO2 target under a mixture of hydrogen/argon plasma in which nitrogen is incorporated in the case of SiOxNy layer. Al/SiOxNy-Sinc/p-Si and Al/SiO2-Sinc/p-Si devices were fabricated and electrically characterized. Results showed a high rectification ratio (>104) for the SiOxNy-based device and a resistive behavior when nitrogen was not incorporating (SiO2-based device). For rectifier devices, the ideality factor depends on the SiOxNy layer thickness. The conduction mechanisms of both MIS diode structures were studied by analyzing thermal and bias dependences of the carriers transport in relation with the nitrogen content

    Observation and study of the decay J/ψϕηηJ/\psi\rightarrow\phi\eta\eta'

    Get PDF
    We report the observation and study of the decay J/ψϕηηJ/\psi\rightarrow\phi\eta\eta' using 1.3×1091.3\times{10^9} J/ψJ/\psi events collected with the BESIII detector. Its branching fraction, including all possible intermediate states, is measured to be (2.32±0.06±0.16)×104(2.32\pm0.06\pm0.16)\times{10^{-4}}. We also report evidence for a structure, denoted as XX, in the ϕη\phi\eta' mass spectrum in the 2.02.12.0-2.1 GeV/c2c^2 region. Using two decay modes of the η\eta' meson (γπ+π\gamma\pi^+\pi^- and ηπ+π\eta\pi^+\pi^-), a simultaneous fit to the ϕη\phi\eta' mass spectra is performed. Assuming the quantum numbers of the XX to be JP=1J^P = 1^-, its significance is found to be 4.4σ\sigma, with a mass and width of (2002.1±27.5±21.4)(2002.1 \pm 27.5 \pm 21.4) MeV/c2c^2 and (129±17±9)(129 \pm 17 \pm 9) MeV, respectively, and a product branching fraction B(J/ψηX)×B(Xϕη)=(9.8±1.2±1.7)×105\mathcal{B}(J/\psi\rightarrow\eta{}X)\times{}\mathcal{B}(X\rightarrow\phi\eta')=(9.8 \pm 1.2 \pm 1.7)\times10^{-5}. Alternatively, assuming JP=1+J^P = 1^+, the significance is 3.8σ\sigma, with a mass and width of (2062.8±13.1±7.2)(2062.8 \pm 13.1 \pm 7.2) MeV/c2c^2 and (177±36±35)(177 \pm 36 \pm 35) MeV, respectively, and a product branching fraction B(J/ψηX)×B(Xϕη)=(9.6±1.4±2.0)×105\mathcal{B}(J/\psi\rightarrow\eta{}X)\times{}\mathcal{B}(X\rightarrow\phi\eta')=(9.6 \pm 1.4 \pm 2.0)\times10^{-5}. The angular distribution of J/ψηXJ/\psi\rightarrow\eta{}X is studied and the two JPJ^P assumptions of the XX cannot be clearly distinguished due to the limited statistics. In all measurements the first uncertainties are statistical and the second systematic.Comment: 10 pages, 6 figures and 4 table

    Evidence of a resonant structure in the e+eπ+D0De^+e^-\to \pi^+D^0D^{*-} cross section between 4.05 and 4.60 GeV

    Get PDF
    The cross section of the process e+eπ+D0De^+e^-\to \pi^+D^0D^{*-} for center-of-mass energies from 4.05 to 4.60~GeV is measured precisely using data samples collected with the BESIII detector operating at the BEPCII storage ring. Two enhancements are clearly visible in the cross section around 4.23 and 4.40~GeV. Using several models to describe the dressed cross section yields stable parameters for the first enhancement, which has a mass of 4228.6 \pm 4.1 \pm 6.3 \un{MeV}/c^2 and a width of 77.0 \pm 6.8 \pm 6.3 \un{MeV}, where the first uncertainties are statistical and the second ones are systematic. Our resonant mass is consistent with previous observations of the Y(4220)Y(4220) state and the theoretical prediction of a DDˉ1(2420)D\bar{D}_1(2420) molecule. This result is the first observation of Y(4220)Y(4220) associated with an open-charm final state. Fits with three resonance functions with additional Y(4260)Y(4260), Y(4320)Y(4320), Y(4360)Y(4360), ψ(4415)\psi(4415), or a new resonance, do not show significant contributions from either of these resonances. The second enhancement is not from a single known resonance. It could contain contributions from ψ(4415)\psi(4415) and other resonances, and a detailed amplitude analysis is required to better understand this enhancement

    Observation of Ds+pnˉD^+_s\rightarrow p\bar{n} and confirmation of its large branching fraction

    Full text link
    The baryonic decay Ds+pnˉD^+_s\rightarrow p\bar{n} is observed, and the corresponding branching fraction is measured to be (1.21±0.10±0.05)×103(1.21\pm0.10\pm0.05)\times10^{-3}, where the first uncertainty is statistical and second systematic. The data sample used in this analysis was collected with the BESIII detector operating at the BEPCII e+ee^+e^- double-ring collider with a center-of-mass energy of 4.178~GeV and an integrated luminosity of 3.19~fb1^{-1}. The result confirms the previous measurement by the CLEO Collaboration and is of greatly improved precision, which may deepen our understanding of the dynamical enhancement of the W-annihilation topology in the charmed meson decays
    corecore