1,885 research outputs found

    Construction and Test of MDT Chambers for the ATLAS Muon Spectrometer

    Full text link
    The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the AT- LAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurized drift tubes on either side of a space frame carrying an optical monitoring system to correct for deformations. The full-scale prototype of a large MDT chamber has been constructed with methods suitable for large-scale production. X-ray measurements at CERN showed a positioning accuracy of the sense wires in the chamber of better than the required 20 ?microns (rms). The performance of the chamber was studied in a muon beam at CERN. Chamber production for ATLAS now has started

    Construction and Test of the Precision Drift Chambers for the ATLAS Muon Spectrometer

    Full text link
    The Monitored Drift Tube (MDT) chambers for the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) consist of 3-4 layers of pressurised drift tubes on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 microns with a single-tube resolution of at least 80 microns and a sense wire positioning accu- racy of 20 ?microns (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 m length. For the ATLAS muon spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a wire positioning accuracy of 14 microns (rms)

    Mathematical model for multicomponent separations on the continuous annular chromatograph

    Get PDF
    A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally

    Increased incidence of postoperative infections during prophylaxis with cephalothin compared to doxycycline in intestinal surgery

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The antibiotics used for prophylaxis during surgery may influence the rate of surgical site infections. Tetracyclines are attractive having a long half-life and few side effects when used in a single dose regimen. We studied the rate of surgical site infections during changing regimens of antibiotic prophylaxis in medium and major size surgery.</p> <p>Methods</p> <p>Prospective registration of surgical site infection following intestinal resections and hysterectomies was performed. Possible confounding procedure and patient related factors were registered. The study included 1541 procedures and 1489 controls. The registration included time periods when the regimen was changed from doxycycline to cephalothin and back again.</p> <p>Results</p> <p>The SSI in the colorectal department increased from 19% to 30% (p = 0.002) when doxycycline was substituted with cephalothin and decreased to 17% when we changed back to doxycycline (p = 0.005). In the gynaecology department the surgical site infection rate did not increase significantly. Subgroup analysis showed major changes in infections in rectal resections from 20% to 35% (p = 0.02) and back to 12% (p = 0.003).</p> <p>Conclusion</p> <p>Doxycycline combined with metronidazole, is an attractive candidate for antibiotic prophylaxis in medium and major size intestinal surgery.</p

    Cefuroxime Pharmacokinetics in Pediatric Cardiovascular Surgery Patients Undergoing Cardiopulmonary Bypass

    Get PDF
    Objectives The objective of this study was to determine the pharmacokinetics of cefuroxime in children undergoing cardiopulmonary bypass (CPB) for cardiovascular surgery. Design A prospective study. Setting A tertiary pediatric teaching hospital. Participants Infants and children undergoing CPB were enrolled in the study. Intervention An initial dose (mean, 24.2 ± 1.6 mg/kg) of cefuroxime was administered before surgical incision, and a second dose (mean, 14.4 ± 7.9 mg/kg) was administered in the CPB prime solution. Serial blood samples were obtained before, during, and after the CPB process. Samples were shipped on dry ice to the analytic laboratory and concentrations determined by a validated high-performance liquid chromatography method. A 2-compartment pharmacokinetic model was fitted to the data using maximum a priori–Bayesian estimation, with weight as a covariate. Monte Carlo simulations of a single-dose (25 mg/kg pre-CPB) approach and a 2-dose (25 mg/kg pre- and 12.5-mg/kg prime solution dose) approach were performed. Measurements and Main Results Fifteen subjects (9 males/6 females) were enrolled in the study, with median (range) age and weight of 11 (3-34) months and 9.5 (4.5-15.4) kg, respectively. The median (range) duration of CPB was 136 (71-243) minutes. Median and range cefuroxime pharmacokinetic parameters were as follows: maximum concentration (Cmax) dose, 1: 328 (150-512) μg/mL; systemic clearance, 0.050 (0.041-0.058) L/h/kg; steady-state volume of distribution, 0.213 (0.081-0.423) L/kg; volume of distribution in the central compartment, 0.081 (0.046-0.162) L/kg; and elimination half-life, 3.76 (1.03-6.81) hours. The median 8-hour post–dose-simulated cefuroxime concentrations were 26.5 and 16.0 mg/L for the 2-dose and single-dose regimens, respectively. Conclusion Manufacturers recommend that pediatric doses of cefuroxime (25-50 mg/kg) can be used in infants and children undergoing CPB to maintain adequate serum concentrations for surgical-site infection prophylaxis. A second intraoperative dose, administered through the CPB circuit, provides no additional prophylactic advantage

    Lambda and Antilambda polarization from deep inelastic muon scattering

    Full text link
    We report results of the first measurements of Lambda and Antilambda polarization produced in deep inelastic polarized muon scattering on the nucleon. The results are consistent with an expected trend towards positive polarization with increasing x_F. The polarizations of Lambda and Antilambda appear to have opposite signs. A large negative polarization for Lambda at low positive x_F is observed and is not explained by existing models.A possible interpretation is presented.Comment: 9 pages, 2 figure

    Use of Medicare diagnosis and procedure codes to improve detection of surgical site infections following hip arthroplasty, knee arthroplasty, and vascular surgery

    Get PDF
    ObjectiveTo evaluate the use of routinely collected electronic health data in Medicare claims to identify surgical site infections (SSIs) following hip arthroplasty, knee arthroplasty, and vascular surgery.DesignRetrospective cohort study.SettingFour academic hospitals that perform prospective SSI surveillance.MethodsWe developed lists of International Classification of Diseases, Ninth Revision, and Current Procedural Terminology diagnosis and procedure codes to identify potential SSIs. We then screened for these codes in Medicare claims submitted by each hospital on patients older than 65 years of age who had undergone 1 of the study procedures during 2007. Each site reviewed medical records of patients identified by either claims codes or traditional infection control surveillance to confirm SSI using Centers for Disease Control and Prevention/National Healthcare Safety Network criteria. We assessed the performance of both methods against all chart-confirmed SSIs identified by either method.ResultsClaims-based surveillance detected 1.8-4.7-fold more SSIs than traditional surveillance, including detection of all previously identified cases. For hip and vascular surgery, there was a 5-fold and 1.6-fold increase in detection of deep and organ/space infections, respectively, with no increased detection of deep and organ/space infections following knee surgery. Use of claims to trigger chart review led to confirmation of SSI in 1 out of 3 charts for hip arthroplasty, 1 out of 5 charts for knee arthroplasty, and 1 out of 2 charts for vascular surgery.ConclusionClaims-based SSI surveillance markedly increased the number of SSIs detected following hip arthroplasty, knee arthroplasty, and vascular surgery. It deserves consideration as a more effective approach to target chart reviews for identifying SSIs

    Shadowing in Inelastic Scattering of Muons on Carbon, Calcium and Lead at Low XBj

    Full text link
    Nuclear shadowing is observed in the per-nucleon cross-sections of positive muons on carbon, calcium and lead as compared to deuterium. The data were taken by Fermilab experiment E665 using inelastically scattered muons of mean incident momentum 470 GeV/c. Cross-section ratios are presented in the kinematic region 0.0001 < XBj <0.56 and 0.1 < Q**2 < 80 GeVc. The data are consistent with no significant nu or Q**2 dependence at fixed XBj. As XBj decreases, the size of the shadowing effect, as well as its A dependence, are found to approach the corresponding measurements in photoproduction.Comment: 22 pages, incl. 6 figures, to be published in Z. Phys.

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal
    • …
    corecore