1,629 research outputs found

    Characterization of Large Volume 3.5 x 8 inches LaBr3:Ce Detectors

    Full text link
    The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever produced and still need to be fully characterized to determine how these detectors can be utilized and in which applications. We tested the detectors using monochromatic gamma-ray sources and in-beam reactions producing gamma rays up to 22.6 MeV; we acquired PMT signal pulses and calculated detector energy resolution and response linearity as a function of gamma-ray energy. Two different voltage dividers were coupled to the Hamamatsu R10233-100SEL PMT: the Hamamatsu E1198-26, based on straightforward resistive network design, and the LABRVD, specifically designed for our large volume LaBr3:Ce scintillation detectors, which also includes active semiconductor devices. Because of the extremely high light yield of LaBr3:Ce crystals we observed that, depending on the choice of PMT, voltage divider and applied voltage, some significant deviation from the ideally proportional response of the detector and some pulse shape deformation appear. In addition, crystal non-homogeneities and PMT gain drifts affect the (measured) energy resolution especially in case of high-energy gamma rays. We also measured the time resolution of detectors with different sizes (from 1x1 inches up to 3.5x8 inches), correlating the results with both the intrinsic properties of PMTs and GEANT simulations of the scintillation light collection process. The detector absolute full energy efficiency was measured and simulated up to gamma-rays of 30 Me

    School performance in Australia: is there a role for quasi-markets?

    Get PDF
    Recent changes to the organisation of Australia's education system have raised the possibility of implementing wide-ranging market reforms. In this article we discuss the scope for introducing reforms similar to the United Kingdom's 'quasi-market' model. We discuss the role of school league tables in providing signals and incentives in a quasi-market. Specifically, we compare a range of unadjusted and model-based league tables of primary school performance in Queensland's public education system. These comparisons indicate that model-based tables which account for socio-economic status and student intake quality vary significantly from the unadjusted tables

    Characterization of Large Volume 3.5″ x 8″ LaBr3:Ce Detectors for the HECTOR+ array

    Get PDF
    A selection of the properties of large volume, cylindrical 3.5" x 8" LaBr 3 :Ce scintillation detectors coupled to a 3.5" PMT (model R10233-1000SEL from HAMAMATSU) and a special designed Voltage Divider (LABRVD) will be discussed. A number of 10 of such detectors constitute the HECTOR + array which, in fall 2012, measured at GSI coupled to the AGATA DEMOSTRATOR at the PRESPEC experimental setup. These crystals are among the largest ever produced and needed to be characterized. We have performed several tests and here we discuss, in particular, the energy resolution measured using monochromatic γ −ray sources and in-beam reactions producing γ −rays up to 22.6 MeV. As already measured in two previous works a saturation in the energy resolution was observed in case of high energy gamma rays. Crystal non-homogeneities and PMT gain drifts can affect the resolution of measurements especially in case of high energy γ −rays

    Labor Productivity - The Use of Staffing Guides and Other Productivity Methods in U.S. Hotels: A Survey Study

    Get PDF
    This paper examines the issue of labor productivity in hotels. It elaborates on various measurement methods used by American hoteliers including staffing guides, with a special focus on productivity standards. Advantages of physical, financial and mixed methods such as percentage methods, revenue per employee, value-added, Data Envelope Analysis and Stochastic Frontier Analysis are discussed. While the use of percentages and staffing guides were found to be commonplace, results revealed that some fairly stable standards were already in place in the surveyed hotels. Results also revealed that at least in the surveyed companies, few hoteliers attempted to monitor or improve revenue per employee, focusing instead on physical labor inputs and outputs or simple labor percentages

    Standalone vertex finding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011

    Measurements of Higgs boson production and couplings in diboson final states with the ATLAS detector at the LHC

    Get PDF
    Measurements are presented of production properties and couplings of the recently discovered Higgs boson using the decays into boson pairs, H →γ γ, H → Z Z∗ →4l and H →W W∗ →lνlν. The results are based on the complete pp collision data sample recorded by the ATLAS experiment at the CERN Large Hadron Collider at centre-of-mass energies of √s = 7 TeV and √s = 8 TeV, corresponding to an integrated luminosity of about 25 fb−1. Evidence for Higgs boson production through vector-boson fusion is reported. Results of combined fits probing Higgs boson couplings to fermions and bosons, as well as anomalous contributions to loop-induced production and decay modes, are presented. All measurements are consistent with expectations for the Standard Model Higgs boson
    corecore