139 research outputs found
Influence of lasers propagation delay on the sensitivity of atom interferometers
In atom interferometers based on two photon transitions, the delay induced by
the difference of the laser beams paths makes the interferometer sensitive to
the fluctuations of the frequency of the lasers. We first study, in the general
case, how the laser frequency noise affects the performance of the
interferometer measurement. Our calculations are compared with the measurements
performed on our cold atom gravimeter based on stimulated Raman transitions. We
finally extend this study to the case of cold atom gradiometers.Comment: 17 pages, 6 figure
Coherent matter wave inertial sensors for precision measurements in space
We analyze the advantages of using ultra-cold coherent sources of atoms for
matter-wave interferometry in space. We present a proof-of-principle experiment
that is based on an analysis of the results previously published in [Richard et
al., Phys. Rev. Lett., 91, 010405 (2003)] from which we extract the ratio h/m
for 87Rb. This measurement shows that a limitation in accuracy arises due to
atomic interactions within the Bose-Einstein condensate
Limits to the sensitivity of a low noise compact atomic gravimeter
A detailed analysis of the most relevant sources of phase noise in an atomic
interferometer is carried out, both theoretically and experimentally. Even a
short interrogation time of 100 ms allows our cold atom gravimeter to reach an
excellent short term sensitivity to acceleration of g at 1s.
This result relies on the combination of a low phase noise laser system,
efficient detection scheme and good shielding from vibrations. In particular,
we describe a simple and robust technique of vibration compensation, which is
based on correcting the interferometer signal by using the AC acceleration
signal measured by a low noise seismometer.Comment: 30 pages, 14 figure
Bedforms and sedimentary structures related to supercritical flows in glacigenic settings
Upper-flow-regime bedforms, including upper-stage-plane beds, antidunes, chutes-and-pools and cyclic steps, are ubiquitous in glacigenic depositional environments characterized by abundant meltwater discharge and sediment supply. In this study, the depositional record of Froude near-critical and supercritical flows in glacigenic settings is reviewed, and similarities and differences between different depositional environments are discussed. Upper-flow-regime bedforms may occur in subglacial, subaerial and subaqueous environments, recording deposition by free-surface flows and submerged density flows. Although individual bedform types are generally not indicative of any specific depositional environment, some observed trends are similar to those documented in non-glacigenic settings. Important parameters for bedform evolution that differ between depositional environments include flow confinement, bed slope, aggradation rate and grain size. Cyclic-step deposits are more common in confined settings, like channels or incised valleys, or steep slopes of coarse-grained deltas. Antidune deposits prevail in unconfined settings and on more gentle slopes, like glacifluvial fans, sand-rich delta slopes or subaqueous (ice-contact) fans. At low aggradation rates, only the basal portions of bedforms are preserved, such as scour fills related to the hydraulic-jump zone of cyclic steps or antidune-wave breaking, which are common in glacifluvial systems and during glacial lake-outburst floods and (related) lake-level falls. Higher aggradation rates result in increased preservation potential, possibly leading to the preservation of complete bedforms. Such conditions are met in sediment-laden jökulhlaups and subaqueous proglacial environments characterized by expanding density flows. Coarser-grained sediment leads to steeper bedform profiles and highly scoured facies architectures, while finer-grained deposits display less steep bedform architectures. Such differences are in part related to stronger flows, faster settling of coarse clasts, and more rapid breaking of antidune waves or hydraulic-jump formation over hydraulically rough beds. © 2020 The Authors. Sedimentology published by John Wiley & Sons Ltd on behalf of International Association of Sedimentologist
Atom lasers: production, properties and prospects for precision inertial measurement
We review experimental progress on atom lasers out-coupled from Bose-Einstein
condensates, and consider the properties of such beams in the context of
precision inertial sensing. The atom laser is the matter-wave analog of the
optical laser. Both devices rely on Bose-enhanced scattering to produce a
macroscopically populated trapped mode that is output-coupled to produce an
intense beam. In both cases, the beams often display highly desirable
properties such as low divergence, high spectral flux and a simple spatial mode
that make them useful in practical applications, as well as the potential to
perform measurements at or below the quantum projection noise limit. Both
devices display similar second-order correlations that differ from thermal
sources. Because of these properties, atom lasers are a promising source for
application to precision inertial measurements.Comment: This is a review paper. It contains 40 pages, including references
and figure
Study of 300,486 individuals identifies 148 independent genetic loci influencing general cognitive function
Correction Volume: 10, Article Number: 2068 DOI: 10.1038/s41467-019-10160-w WOS:000466339700001General cognitive function is a prominent and relatively stable human trait that is associated with many important life outcomes. We combine cognitive and genetic data from the CHARGE and COGENT consortia, and UK Biobank (total N = 300,486; age 16-102) and find 148 genome-wide significant independent loci (P <5 x 10(-8)) associated with general cognitive function. Within the novel genetic loci are variants associated with neurodegenerative and neurodevelopmental disorders, physical and psychiatric illnesses, and brain structure. Gene-based analyses find 709 genes associated with general cognitive function. Expression levels across the cortex are associated with general cognitive function. Using polygenic scores, up to 4.3% of variance in general cognitive function is predicted in independent samples. We detect significant genetic overlap between general cognitive function, reaction time, and many health variables including eyesight, hypertension, and longevity. In conclusion we identify novel genetic loci and pathways contributing to the heritability of general cognitive function.Peer reviewe
Author Correction:Study of 300,486 individuals identifies 148 independent genetic loci influencing general cognitive function
Christina M. Lill, who contributed to analysis of data, was inadvertently omitted from the author list in the originally published version of this article. This has now been corrected in both the PDF and HTML versions of the article
- âŠ