777 research outputs found

    Black & white continuous tone printing using multiple negative working plates, so that each plate prints an equal segment of a determined density range

    Get PDF
    Continuous tone printing, either collotype or screenless lithography, are processes that are in limited use. The halftone method of reproduction is still the most economical way to reproduce a continuous tone original. This study dealt with the mechanism of screenless lithography, more specifically on how to make the use of negative working plates a feasible alternative to positive working plates. It is known that the positive working plate can print a longer range of tones than a negative working plate. So the main point of the experiment dealt with how to extend the range of a negative working plate. A negative plate is of high contrast, and so multiple negative working plates were used to print one image. Each plate in itself can print three to four steps of a continuous tone step wedge. In this experiment, three plates were used in the hopes of printing twelve steps in a continuous gradation. A continuous tone step wedge along with a black and white photograph were divided among the three plates. Twelve steps on the step wedge were identified, and so each film had four of the possible thirty steps which existed on the step wedge. These films were exposed to plates, and mounted on the press. Each image was run in registration with one another, and the solid ink density was varied to produce the continuous tone effect. From the press sheets examined, in which there are examples in this report, a high contrast image was produced. One of the main problems in the experiment was differences in emulsion coating on each individual plate. Which resulted in inconsistent exposure times from one plate to another. From repeated plate testing using a .15 density increment continuous tone step wedge as a control guide, it was found that for the same exposure a hardening of the plate coating (and consequently of ink receptivity) corresponding to two steps equaling .30 density difference was to be expected. This made it virtually impossible to get a handle on the correct exposure time needed for the plate. Results from this experiment show, that it is not possible to effectively print a continuous tone image with a negative working plate and or multiple negative plates. This is due to the high contrast of the negative working plate, thus making it suitable for mainly halftone lithographic purposes

    Active vitamin D (1,25-dihydroxyvitamin D) and bone health in middle-aged and elderly men: the European male aging study (EMAS)

    Get PDF
    <p>Context: There is little information on the potential impact of serum 1,25-dihydroxyvitamin D [1,25(OH)2D] on bone health including turnover.</p> <p>Objective: The objective of the study was to determine the influence of 1,25(OH)2D and 25-hydroxyvitamin D [25(OH)D] on bone health in middle-aged and older European men.</p> <p>Design, Setting, and Participants: Men aged 40–79 years were recruited from population registers in 8 European centers. Subjects completed questionnaires that included questions concerning lifestyle and were invited to attend for quantitative ultrasound (QUS) of the heel, assessment of height and weight, and a fasting blood sample from which 1,25(OH)2D, 25(OH)D, and PTH were measured. 1,25(OH)2D was measured using liquid chromatography tandem mass spectrometry. Bone markers serum N-terminal propeptide of type 1 procollagen (P1NP) and crosslinks (β-cTX) were also measured. Dual-energy x-ray absorptiometry (DXA) of the hip and lumbar spine was performed in 2 centers.</p> <p>Main Outcome Measure(s): QUS of the heel, bone markers P1NP and β-cTX, and DXA of the hip and lumbar spine were measured.</p> <p>Results: A total of 2783 men, mean age 60.0 years (SD 11.0) were included in the analysis. After adjustment for age and center, 1,25(OH)2D was positively associated with 25(OH)D but not with PTH. 25(OH)D was negatively associated with PTH. After adjustment for age, center, height, weight, lifestyle factors, and season, 1,25(OH)2D was associated negatively with QUS and DXA parameters and associated positively with β-cTX. 1,25(OH)2D was not correlated with P1NP. 25(OH)D was positively associated with the QUS and DXA parameters but not related to either bone turnover marker. Subjects with both high 1,25(OH)2D (upper tertile) and low 25(OH)D (lower tertile) had the lowest QUS and DXA parameters and the highest β-cTX levels.</p> <p>Conclusions: Serum 1,25(OH)2D is associated with higher bone turnover and poorer bone health despite being positively related to 25(OH)D. A combination of high 1,25(OH)2D and low 25(OH)D is associated with the poorest bone health.</p&gt

    Active vitamin D (1,25-dihydroxyvitamin D) and bone health in middle-aged and elderly men: the European male aging study (EMAS)

    Get PDF
    <p>Context: There is little information on the potential impact of serum 1,25-dihydroxyvitamin D [1,25(OH)2D] on bone health including turnover.</p> <p>Objective: The objective of the study was to determine the influence of 1,25(OH)2D and 25-hydroxyvitamin D [25(OH)D] on bone health in middle-aged and older European men.</p> <p>Design, Setting, and Participants: Men aged 40–79 years were recruited from population registers in 8 European centers. Subjects completed questionnaires that included questions concerning lifestyle and were invited to attend for quantitative ultrasound (QUS) of the heel, assessment of height and weight, and a fasting blood sample from which 1,25(OH)2D, 25(OH)D, and PTH were measured. 1,25(OH)2D was measured using liquid chromatography tandem mass spectrometry. Bone markers serum N-terminal propeptide of type 1 procollagen (P1NP) and crosslinks (β-cTX) were also measured. Dual-energy x-ray absorptiometry (DXA) of the hip and lumbar spine was performed in 2 centers.</p> <p>Main Outcome Measure(s): QUS of the heel, bone markers P1NP and β-cTX, and DXA of the hip and lumbar spine were measured.</p> <p>Results: A total of 2783 men, mean age 60.0 years (SD 11.0) were included in the analysis. After adjustment for age and center, 1,25(OH)2D was positively associated with 25(OH)D but not with PTH. 25(OH)D was negatively associated with PTH. After adjustment for age, center, height, weight, lifestyle factors, and season, 1,25(OH)2D was associated negatively with QUS and DXA parameters and associated positively with β-cTX. 1,25(OH)2D was not correlated with P1NP. 25(OH)D was positively associated with the QUS and DXA parameters but not related to either bone turnover marker. Subjects with both high 1,25(OH)2D (upper tertile) and low 25(OH)D (lower tertile) had the lowest QUS and DXA parameters and the highest β-cTX levels.</p> <p>Conclusions: Serum 1,25(OH)2D is associated with higher bone turnover and poorer bone health despite being positively related to 25(OH)D. A combination of high 1,25(OH)2D and low 25(OH)D is associated with the poorest bone health.</p&gt

    Ultrafast, Zero-Bias, Graphene Photodetectors with Polymeric Gate Dielectric on Passive Photonic Waveguides.

    Get PDF
    We report compact, scalable, high-performance, waveguide integrated graphene-based photodetectors (GPDs) for telecom and datacom applications, not affected by dark current. To exploit the photothermoelectric (PTE) effect, our devices rely on a graphene/polymer/graphene stack with static top split gates. The polymeric dielectric, poly(vinyl alcohol) (PVA), allows us to preserve graphene quality and to generate a controllable p-n junction. Both graphene layers are fabricated using aligned single-crystal graphene arrays grown by chemical vapor deposition. The use of PVA yields a low charge inhomogeneity ∼8 × 1010 cm-2 at the charge neutrality point, and a large Seebeck coefficient ∼140 μV K-1, enhancing the PTE effect. Our devices are the fastest GPDs operating with zero dark current, showing a flat frequency response up to 67 GHz without roll-off. This performance is achieved on a passive, low-cost, photonic platform, and does not rely on nanoscale plasmonic structures. This, combined with scalability and ease of integration, makes our GPDs a promising building block for next-generation optical communication devices

    A Study of Time-Dependent CP-Violating Asymmetries and Flavor Oscillations in Neutral B Decays at the Upsilon(4S)

    Get PDF
    We present a measurement of time-dependent CP-violating asymmetries in neutral B meson decays collected with the BABAR detector at the PEP-II asymmetric-energy B Factory at the Stanford Linear Accelerator Center. The data sample consists of 29.7 fb1{\rm fb}^{-1} recorded at the Υ(4S)\Upsilon(4S) resonance and 3.9 fb1{\rm fb}^{-1} off-resonance. One of the neutral B mesons, which are produced in pairs at the Υ(4S)\Upsilon(4S), is fully reconstructed in the CP decay modes J/ψKS0J/\psi K^0_S, ψ(2S)KS0\psi(2S) K^0_S, χc1KS0\chi_{c1} K^0_S, J/ψK0J/\psi K^{*0} (K0KS0π0K^{*0}\to K^0_S\pi^0) and J/ψKL0J/\psi K^0_L, or in flavor-eigenstate modes involving D()π/ρ/a1D^{(*)}\pi/\rho/a_1 and J/ψK0J/\psi K^{*0} (K0K+πK^{*0}\to K^+\pi^-). The flavor of the other neutral B meson is tagged at the time of its decay, mainly with the charge of identified leptons and kaons. The proper time elapsed between the decays is determined by measuring the distance between the decay vertices. A maximum-likelihood fit to this flavor eigenstate sample finds Δmd=0.516±0.016(stat)±0.010(syst)ps1\Delta m_d = 0.516\pm 0.016 {\rm (stat)} \pm 0.010 {\rm (syst)} {\rm ps}^{-1}. The value of the asymmetry amplitude sin2β\sin2\beta is determined from a simultaneous maximum-likelihood fit to the time-difference distribution of the flavor-eigenstate sample and about 642 tagged B0B^0 decays in the CP-eigenstate modes. We find sin2β=0.59±0.14(stat)±0.05(syst)\sin2\beta=0.59\pm 0.14 {\rm (stat)} \pm 0.05 {\rm (syst)}, demonstrating that CP violation exists in the neutral B meson system. (abridged)Comment: 58 pages, 35 figures, submitted to Physical Review

    Measurement of the branching fraction and CP content for the decay B(0) -> D(*+)D(*-)

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APS.We report a measurement of the branching fraction of the decay B0→D*+D*- and of the CP-odd component of its final state using the BABAR detector. With data corresponding to an integrated luminosity of 20.4  fb-1 collected at the Υ(4S) resonance during 1999–2000, we have reconstructed 38 candidate signal events in the mode B0→D*+D*- with an estimated background of 6.2±0.5 events. From these events, we determine the branching fraction to be B(B0→D*+D*-)=[8.3±1.6(stat)±1.2(syst)]×10-4. The measured CP-odd fraction of the final state is 0.22±0.18(stat)±0.03(syst).This work is supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the A.P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Search for CP Violation in the Decay Z -> b (b bar) g

    Full text link
    About three million hadronic decays of the Z collected by ALEPH in the years 1991-1994 are used to search for anomalous CP violation beyond the Standard Model in the decay Z -> b \bar{b} g. The study is performed by analyzing angular correlations between the two quarks and the gluon in three-jet events and by measuring the differential two-jet rate. No signal of CP violation is found. For the combinations of anomalous CP violating couplings, h^b=h^AbgVbh^VbgAb{\hat{h}}_b = {\hat{h}}_{Ab}g_{Vb}-{\hat{h}}_{Vb}g_{Ab} and hb=h^Vb2+h^Ab2h^{\ast}_b = \sqrt{\hat{h}_{Vb}^{2}+\hat{h}_{Ab}^{2}}, limits of \hat{h}_b < 0.59and and h^{\ast}_{b} < 3.02$ are given at 95\% CL.Comment: 8 pages, 1 postscript figure, uses here.sty, epsfig.st

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter

    Measurement of D-s(+) and D-s(*+) production in B meson decays and from continuum e(+)e(-) annihilation at √s=10.6 GeV

    Get PDF
    This is the pre-print version of the Article. The official published version can be accessed from the links below. Copyright @ 2002 APSNew measurements of Ds+ and Ds*+ meson production rates from B decays and from qq̅ continuum events near the Υ(4S) resonance are presented. Using 20.8 fb-1 of data on the Υ(4S) resonance and 2.6 fb-1 off-resonance, we find the inclusive branching fractions B(B⃗Ds+X)=(10.93±0.19±0.58±2.73)% and B(B⃗Ds*+X)=(7.9±0.8±0.7±2.0)%, where the first error is statistical, the second is systematic, and the third is due to the Ds+→φπ+ branching fraction uncertainty. The production cross sections σ(e+e-→Ds+X)×B(Ds+→φπ+)=7.55±0.20±0.34pb and σ(e+e-→Ds*±X)×B(Ds+→φπ+)=5.8±0.7±0.5pb are measured at center-of-mass energies about 40 MeV below the Υ(4S) mass. The branching fractions ΣB(B⃗Ds(*)+D(*))=(5.07±0.14±0.30±1.27)% and ΣB(B⃗Ds*+D(*))=(4.1±0.2±0.4±1.0)% are determined from the Ds(*)+ momentum spectra. The mass difference m(Ds+)-m(D+)=98.4±0.1±0.3MeV/c2 is also measured.This work was supported by DOE and NSF (USA), NSERC (Canada), IHEP (China), CEA and CNRS-IN2P3 (France), BMBF (Germany), INFN (Italy), NFR (Norway), MIST (Russia), and PPARC (United Kingdom). Individuals have received support from the Swiss NSF, A. P. Sloan Foundation, Research Corporation, and Alexander von Humboldt Foundation

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal
    corecore