500 research outputs found

    Initial experience with off-pump left ventricular assist device implantation in single center: retrospective analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We hypothesize that implantation of left ventricular assist device through off-pump technique is feasible and has a comparable result to implantation on cardiopulmonary bypass and could improve one-year survival.</p> <p>Methods</p> <p>This retrospective, observational, single-center study was conducted on 29 consecutive patients at our institution who underwent off-pump left ventricular assist device implantation by a single surgeon.</p> <p>Results</p> <p>Twenty-seven procedures were performed successfully using the off-pump technique. The survival rate was 92% at 30 days, 76% at 90 days, and 67% at one year. We compared the one-year survival of different implantation periods, and divided our study into three time intervals (2004-2005, 2006, and 2007). There was a trend in reduction in number of deaths over one year that demonstrated a decrease in death rate from 50% to 17%, as well as improvement in our experience over time. However, this trend is not statistically significant (p = 0.08) due to limited sample size.</p> <p>Conclusions</p> <p>Based upon our findings, off-pump left ventricular assist device implantation is a feasible surgical technique, and combining this technique with improved device technology in the future may provide even greater improvement in patient outcomes.</p

    Virtual Reality Applications in Rehabilitation

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/978-3-319-39510-4_1One of the most valuable applications of virtual reality (VR) is in the domain of rehabilitation. After brain injuries or diseases, many patients suffer from impaired physical and/or cognitive capabilities, such as difficulties in moving arms or remembering names. Over the past two decades, VR has been tested and examined as a technology to assist patients’ recovery and rehabilitation, both physical and cognitive. The increasing prevalence of low-cost VR devices brings new opportunities, allowing VR to be used in practice. Using VR devices such as head-mounted displays (HMDs), special virtual scenes can be designed to assist patients in the process of re-training their brain and reorganizing their functions and abilities. However, such VR interfaces and applications must be comprehensively tested and examined for their effectiveness and potential side effects. This paper presents a review of related literature and discusses the new opportunities and challenges. Most of existing studies examined VR as an assessment method rather than a training/exercise method. Nevertheless, promising cases and positive preliminary results have been shown. Considering the increasing need for self-administered, home-based, and personalized rehabilitation, VR rehabilitation is potentially an important approach. This area requires more studies and research effort

    CD98hc facilitates B cell proliferation and adaptive humoral immunity.

    Get PDF
    The proliferation of antigen-specific lymphocytes and resulting clonal expansion are essential for adaptive immunity. We report here that B cell-specific deletion of the heavy chain of CD98 (CD98hc) resulted in lower antibody responses due to total suppression of B cell proliferation and subsequent plasma cell formation. Deletion of CD98hc did not impair early B cell activation but did inhibit later activation of the mitogen-activated protein kinase Erk1/2 and downregulation of the cell cycle inhibitor p27. Reconstitution of CD98hc-deficient B cells with CD98hc mutants showed that the integrin-binding domain of CD98hc was required for B cell proliferation but that the amino acid-transport function of CD98hc was dispensable for this. Thus, CD98hc supports integrin-dependent rapid proliferation of B cells. We propose that the advantage of adaptive immunity favored the appearance of CD98hc in vertebrates

    Using functional genomics to decipher the complexity of microbial pathogenicity

    Get PDF
    From the first identification of bacteria as a causative agent of disease, researchers have been developing methods and techniques to understand their pathogenic processes. For decades, this work has been limited to looking at a small number of genetically manipulatable isolates in in vitro assays or animal models of infection. Despite these limitations such work has facilitated the development of successful therapeutic strategies, most notably vaccines that target specific virulence-related features. There are however many antimicrobial resistant pathogens for which vaccination strategies have not worked, as we simply do not know enough about how they cause disease. We are however at the dawn of a new era in the study of microbial pathogenicity, where large collections of bacteria isolated directly from human infections can be sequenced and assayed to identify the bacterial features that affect disease severity in humans. Here, we describe our attempt to perform such a study focussed on the major human pathogen Staphylococcus aureus, which demonstrates the step changes such approaches can make to understanding microbial pathogenicity

    User-centered virtual environment design for virtual rehabilitation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As physical and cognitive rehabilitation protocols utilizing virtual environments transition from single applications to comprehensive rehabilitation programs there is a need for a new design cycle methodology. Current human-computer interaction designs focus on usability without benchmarking technology within a user-in-the-loop design cycle. The field of virtual rehabilitation is unique in that determining the efficacy of this genre of computer-aided therapies requires prior knowledge of technology issues that may confound patient outcome measures. Benchmarking the technology (e.g., displays or data gloves) using healthy controls may provide a means of characterizing the "normal" performance range of the virtual rehabilitation system. This standard not only allows therapists to select appropriate technology for use with their patient populations, it also allows them to account for technology limitations when assessing treatment efficacy.</p> <p>Methods</p> <p>An overview of the proposed user-centered design cycle is given. Comparisons of two optical see-through head-worn displays provide an example of benchmarking techniques. Benchmarks were obtained using a novel vision test capable of measuring a user's stereoacuity while wearing different types of head-worn displays. Results from healthy participants who performed both virtual and real-world versions of the stereoacuity test are discussed with respect to virtual rehabilitation design.</p> <p>Results</p> <p>The user-centered design cycle argues for benchmarking to precede virtual environment construction, especially for therapeutic applications. Results from real-world testing illustrate the general limitations in stereoacuity attained when viewing content using a head-worn display. Further, the stereoacuity vision benchmark test highlights differences in user performance when utilizing a similar style of head-worn display. These results support the need for including benchmarks as a means of better understanding user outcomes, especially for patient populations.</p> <p>Conclusions</p> <p>The stereoacuity testing confirms that without benchmarking in the design cycle poor user performance could be misconstrued as resulting from the participant's injury state. Thus, a user-centered design cycle that includes benchmarking for the different sensory modalities is recommended for accurate interpretation of the efficacy of the virtual environment based rehabilitation programs.</p

    A Long Baseline Neutrino Oscillation Experiment Using J-PARC Neutrino Beam and Hyper-Kamiokande

    Get PDF
    Document submitted to 18th J-PARC PAC meeting in May 2014. 50 pages, 41 figuresDocument submitted to 18th J-PARC PAC meeting in May 2014. 50 pages, 41 figuresDocument submitted to 18th J-PARC PAC meeting in May 2014. 50 pages, 41 figuresHyper-Kamiokande will be a next generation underground water Cherenkov detector with a total (fiducial) mass of 0.99 (0.56) million metric tons, approximately 20 (25) times larger than that of Super-Kamiokande. One of the main goals of Hyper-Kamiokande is the study of CPCP asymmetry in the lepton sector using accelerator neutrino and anti-neutrino beams. In this document, the physics potential of a long baseline neutrino experiment using the Hyper-Kamiokande detector and a neutrino beam from the J-PARC proton synchrotron is presented. The analysis has been updated from the previous Letter of Intent [K. Abe et al., arXiv:1109.3262 [hep-ex]], based on the experience gained from the ongoing T2K experiment. With a total exposure of 7.5 MW ×\times 107^7 sec integrated proton beam power (corresponding to 1.56×10221.56\times10^{22} protons on target with a 30 GeV proton beam) to a 2.52.5-degree off-axis neutrino beam produced by the J-PARC proton synchrotron, it is expected that the CPCP phase δCP\delta_{CP} can be determined to better than 19 degrees for all possible values of δCP\delta_{CP}, and CPCP violation can be established with a statistical significance of more than 3σ3\,\sigma (5σ5\,\sigma) for 7676% (5858%) of the δCP\delta_{CP} parameter space

    Perceived usefulness of a distributed community-based syndromic surveillance system: a pilot qualitative evaluation study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We conducted a pilot utility evaluation and information needs assessment of the Distribute Project at the 2010 Washington State Public Health Association (WSPHA) Joint Conference. Distribute is a distributed community-based syndromic surveillance system and network for detection of influenza-like illness (ILI). Using qualitative methods, we assessed the perceived usefulness of the Distribute system and explored areas for improvement. Nine state and local public health professionals participated in a focus group (<it>n = 6</it>) and in semi-structured interviews (<it>n = 3</it>). Field notes were taken, summarized and analyzed.</p> <p>Findings</p> <p>Several emergent themes that contribute to the perceived usefulness of system data and the Distribute system were identified: 1) <it>Standardization: </it>a common ILI syndrome definition; 2) <it>Regional Comparability: </it>views that support county-by-county comparisons of syndromic surveillance data; 3) <it>Completeness: </it>complete data for all expected data at a given time; <it>4) Coverage: </it>data coverage of all jurisdictions in WA state; 5) <it>Context: </it>metadata incorporated into the views to provide context for graphed data; 6) <it>Trusted Data</it>: verification that information is valid and timely; and 7) <it>Customization: </it>the ability to customize views as necessary. As a result of the focus group, a new county level health jurisdiction expressed interest in contributing data to the Distribute system.</p> <p>Conclusion</p> <p>The resulting themes from this study can be used to guide future information design efforts for the Distribute system and other syndromic surveillance systems. In addition, this study demonstrates the benefits of conducting a low cost, qualitative evaluation at a professional conference.</p

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Attrition and bias in the MRC cognitive function and ageing study: an epidemiological investigation

    Get PDF
    BACKGROUND: Any hypothesis in longitudinal studies may be affected by attrition and poor response rates. The MRC Cognitive Function and Ageing study (MRC CFAS) is a population based longitudinal study in five centres with identical methodology in England and Wales each recruiting approximately 2,500 individuals. This paper aims to identify potential biases in the two-year follow-up interviews. METHODS: Initial non-response: Those not in the baseline interviews were compared in terms of mortality to those who were in the baseline interviews at the time of the second wave interviews (1993–1996). Longitudinal attrition: Logistic regression analysis was used to examine baseline differences between individuals who took part in the two-year longitudinal wave compared with those who did not. RESULTS: Initial non-response: Individuals who moved away after sampling but before baseline interview were 1.8 times more likely to die by two years (95% Confidence interval(CI) 1.3–2.4) compared to respondents, after adjusting for age. The refusers had a slightly higher, but similar mortality pattern to responders (Odds ratio 1.2, 95%CI 1.1–1.4). Longitudinal attrition: Predictors for drop out due to death were being older, male, having impaired activities of daily living, poor self-perceived health, poor cognitive ability and smoking. Similarly individuals who refused were more likely to have poor cognitive ability, but had less years of full-time education and were more often living in their own home though less likely to be living alone. There was a higher refusal rate in the rural centres. Individuals who moved away or were uncontactable were more likely to be single, smokers, demented or depressed and were less likely to have moved if in warden-controlled accommodation at baseline. CONCLUSIONS: Longitudinal estimation of factors mentioned above could be biased, particularly cognitive ability and estimates of movements from own home to residential homes. However, these differences could also affect other investigations, particularly the estimates of incidence and longitudinal effects of health and psychiatric diseases, where the factors shown here to be associated with attrition are risk factors for the diseases. All longitudinal studies should investigate attrition and this may help with aspects of design and with the analysis of specific hypotheses

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore