147 research outputs found

    A comparative study of impact on cognitive function between diabetic and non-diabetic patients in a tertiary care hospital

    Get PDF
    Background: Diabetes Mellitus is a chronic metabolic disorder characterized by hyperglycemia, polyuria, hyperlipidemia etc, resulting from defects in insulin secretion, insulin action or both. It affects various organs of the body including the brain. Cognitive function is the thinking process of the brain. In any chronic disease evaluation of cognitive function is justified as it may affect various common day to day activities.Methods: It is a prospective, observational and non-interventional study. Thirty diabetic patients who were recently started on insulin i.e. within 7 days were enrolled in the study based on inclusion and exclusion criteria. Thirty non diabetic healthy individuals served as a control. Cognitive function was accessed by Adenbrookeā€™s Cognitive Examination (ACE III) at the time of enrollment.Results: The results were analysed using paired t-test. Attention, Memory and Visiospatial ability was significantly reduced in diabetic patients compared to control. Verbal fluency and language was also reduced but the change was not significant. Total ACE III score was significantly reduced in diabetic patients compared to control.Conclusions: Cognitive function is significantly reduced in Diabetic patients recently started on insulin. Hyperglycemia could be the possible reason of cognitive decline. Proper understanding of the natural history of Diabetes and the pathogenesis of cognitive decline as well as control of Diabetes can help to prevent development of cognitive dysfunction

    Clinical and endoscopic features of pill-induced esophagitis

    Get PDF
    Background: Medication can cause an injury in the esophagus by local and systemic effect, leading to esophagitis. Many such medications have been identified as a cause of pill-induced esophagitis. This study was performed to evaluate the clinical and endoscopic findings of pill-induced esophagitis.Methods: This was retrospective observational study, conducted among patients diagnosed endoscopically with pill-induced esophagitis at Ansh gastroenterology clinic, Ahmedabad, India, from April 2017 to March 2021. The data of these patients were recorded in pre-designed case record form by evaluating their past medical records.Results: Total 90 patients were diagnosed with pill-induced esophagitis. Retrosternal chest pain (68.9%), odynophagia (41.1%), dysphagia (25.6%), and epigastric pain (14.4%) were common clinical findings. The major culprit medications were antibiotics, and NSAIDs (non-steroidal anti-inflammatory drugs). Common esophageal endoscopic findings were ulcer (84.4%), erosion (17.8%), and active ulcer bleeding (12.2%). Kissing ulcers were observed in the majority (46.7%) of cases. The majority of ulcer and erosion were located in middle third of the esophagus. All the patients were recovered within 6 to 10 days after treatment with PPIs (proton pump inhibitors) and/or antacids, and withdrawal of the causative medication.Conclusions: Pill-induced esophagitis commonly manifests as retrosternal chest pain, odynophagia and dysphagia, and endoscopy reveals kissing ulcer and erosion in the majority of cases. The condition can be treated with PPIs and/or antacids, and withdrawal of the offending medication.

    A Prototype Model to Improve Bandwidth of E Shaped Microstrip Patch Antenna

    Get PDF
    In this communication we have demonstrate a prototype model to improvise bandwidth of E shaped microstrip patch antenna. Microstrip patch antenna is widely used in wireless communication system. Patch antenna has number of advantage over other antenna. It is low volume, thin profile configuration, light weight and easy to integrate with accompanying electronics which can made conformal but, Microstrip patch antenna has several limitations like narrow bandwidth and associated tolerance problem, lower gain. Patch antenna can be designed on simulation software like HFSS. This paper present Design and simulation of E shaped microstrip patch antenna and analyzed result Bandwidth, Gain, Return loss etc has been presented.Derived results show that E shaped Patch antenna is better for the improvement of Bandwidth of the antenna

    Failure Predictions of Out-of-Autoclave Sandwich Joints with Delaminations Under Flexure Loads

    Get PDF
    An analysis and a test program was conducted to investigate the damage tolerance of composite sandwich joints. The joints contained a single circular delamination between the face-sheet and the doubler. The coupons were fabricated through out-of-autoclave (OOA) processes, a technology NASA is investigating for joining large composite sections. The four-point bend flexure test was used to induce compression loading into the side of the joint where the delamination was placed. The compression side was chosen since it tends to be one of the most critical loads in launch vehicles. Autoclave cure was used to manufacture the composite sandwich sections, while the doubler was co-bonded onto the sandwich face-sheet using an OOA process after sandwich panels were cured. A building block approach was adopted to characterize the mechanical properties of the joint material, including the fracture toughness between the doubler and face-sheet. Twelve four-point-bend samples were tested, six in the sandwich core ribbon orientation and six in sandwich core cross-ribbon direction. Analysis predicted failure initiation and propagation at the pre-delaminated location, consistent with experimental observations. A building block approach using fracture analyses methods predicted failure loads in close agreement with tests. This investigation demonstrated a small strength reduction due to a flaw of significant size compared to the width of the sample. Therefore, concerns of bonding an OOA material to an in-autoclave material was mitigated for the geometries, materials, and load configurations considered

    Cell freezing protocol suitable for ATAC-Seq on motor neurons derived from human induced pluripotent stem cells

    Get PDF
    In recent years, the assay for transposase-accessible chromatin using sequencing (ATAC-Seq) has become a fundamental tool of epigenomic research. However, it is difficult to perform this technique on frozen samples because freezing cells before extracting nuclei can impair nuclear integrity and alter chromatin structure, especially in fragile cells such as neurons. Our aim was to develop a protocol for freezing neuronal cells that is compatible with ATAC-Seq; we focused on a disease-relevant cell type, namely motor neurons differentiated from induced pluripotent stem cells (iMNs) from a patient affected by spinal muscular atrophy. We found that while flash-frozen iMNs are not suitable for ATAC-Seq, the assay is successful with slow-cooled cryopreserved cells. Using this method, we were able to isolate high quality, intact nuclei, and we verified that epigenetic results from fresh and cryopreserved iMNs quantitatively agree.National Institutes of Health (U.S.) (Grants U54-NS-091046 and U01-CA-184898

    The Event Horizon Telescope Image of the Quasar NRAO 530

    Get PDF
    We report on the observations of the quasar NRAO 530 with the Event Horizon Telescope (EHT) on 2017 April 5āˆ’7, when NRAO 530 was used as a calibrator for the EHT observations of Sagittarius A*. At z = 0.902, this is the most distant object imaged by the EHT so far. We reconstruct the first images of the source at 230 GHz, at an unprecedented angular resolution of āˆ¼20 Ī¼as, both in total intensity and in linear polarization (LP). We do not detect source variability, allowing us to represent the whole data set with static images. The images reveal a bright feature located on the southern end of the jet, which we associate with the core. The feature is linearly polarized, with a fractional polarization of āˆ¼5%-8%, and it has a substructure consisting of two components. Their observed brightness temperature suggests that the energy density of the jet is dominated by the magnetic field. The jet extends over 60 Ī¼as along a position angle āˆ¼ āˆ’28Ā°. It includes two features with orthogonal directions of polarization (electric vector position angle), parallel and perpendicular to the jet axis, consistent with a helical structure of the magnetic field in the jet. The outermost feature has a particularly high degree of LP, suggestive of a nearly uniform magnetic field. Future EHT observations will probe the variability of the jet structure on microarcsecond scales, while simultaneous multiwavelength monitoring will provide insight into the high-energy emission origin

    Comparison of Polarized Radiative Transfer Codes Used by the EHT Collaboration

    Get PDF

    A novel formulation of inhaled sodium cromoglicate (PA101) in idiopathic pulmonary fibrosis and chronic cough: a randomised, double-blind, proof-of-concept, phase 2 trial

    Get PDF
    Background Cough can be a debilitating symptom of idiopathic pulmonary fibrosis (IPF) and is difficult to treat. PA101 is a novel formulation of sodium cromoglicate delivered via a high-efficiency eFlow nebuliser that achieves significantly higher drug deposition in the lung compared with the existing formulations. We aimed to test the efficacy and safety of inhaled PA101 in patients with IPF and chronic cough and, to explore the antitussive mechanism of PA101, patients with chronic idiopathic cough (CIC) were also studied. Methods This pilot, proof-of-concept study consisted of a randomised, double-blind, placebo-controlled trial in patients with IPF and chronic cough and a parallel study of similar design in patients with CIC. Participants with IPF and chronic cough recruited from seven centres in the UK and the Netherlands were randomly assigned (1:1, using a computer-generated randomisation schedule) by site staff to receive PA101 (40 mg) or matching placebo three times a day via oral inhalation for 2 weeks, followed by a 2 week washout, and then crossed over to the other arm. Study participants, investigators, study staff, and the sponsor were masked to group assignment until all participants had completed the study. The primary efficacy endpoint was change from baseline in objective daytime cough frequency (from 24 h acoustic recording, Leicester Cough Monitor). The primary efficacy analysis included all participants who received at least one dose of study drug and had at least one post-baseline efficacy measurement. Safety analysis included all those who took at least one dose of study drug. In the second cohort, participants with CIC were randomly assigned in a study across four centres with similar design and endpoints. The study was registered with ClinicalTrials.gov (NCT02412020) and the EU Clinical Trials Register (EudraCT Number 2014-004025-40) and both cohorts are closed to new participants. Findings Between Feb 13, 2015, and Feb 2, 2016, 24 participants with IPF were randomly assigned to treatment groups. 28 participants with CIC were enrolled during the same period and 27 received study treatment. In patients with IPF, PA101 reduced daytime cough frequency by 31Ā·1% at day 14 compared with placebo; daytime cough frequency decreased from a mean 55 (SD 55) coughs per h at baseline to 39 (29) coughs per h at day 14 following treatment with PA101, versus 51 (37) coughs per h at baseline to 52 (40) cough per h following placebo treatment (ratio of least-squares [LS] means 0Ā·67, 95% CI 0Ā·48ā€“0Ā·94, p=0Ā·0241). By contrast, no treatment benefit for PA101 was observed in the CIC cohort; mean reduction of daytime cough frequency at day 14 for PA101 adjusted for placebo was 6Ā·2% (ratio of LS means 1Ā·27, 0Ā·78ā€“2Ā·06, p=0Ā·31). PA101 was well tolerated in both cohorts. The incidence of adverse events was similar between PA101 and placebo treatments, most adverse events were mild in severity, and no severe adverse events or serious adverse events were reported. Interpretation This study suggests that the mechanism of cough in IPF might be disease specific. Inhaled PA101 could be a treatment option for chronic cough in patients with IPF and warrants further investigation

    Ordered magnetic fields around the 3C 84 central black hole

    Get PDF
    Context. 3C 84 is a nearby radio source with a complex total intensity structure, showing linear polarisation and spectral patterns. A detailed investigation of the central engine region necessitates the use of very-long-baseline interferometry (VLBI) above the hitherto available maximum frequency of 86 GHz.Aims. Using ultrahigh resolution VLBI observations at the currently highest available frequency of 228 GHz, we aim to perform a direct detection of compact structures and understand the physical conditions in the compact region of 3C 84.Methods. We used Event Horizon Telescope (EHT) 228 GHz observations and, given the limited (u; v)-coverage, applied geometric model fitting to the data. Furthermore, we employed quasi-simultaneously observed, ancillary multi-frequency VLBI data for the source in order to carry out a comprehensive analysis of the core structure.Results. We report the detection of a highly ordered, strong magnetic field around the central, supermassive black hole of 3C 84. The brightness temperature analysis suggests that the system is in equipartition. We also determined a turnover frequency of gamma(m) = (113 +/- 4) GHz, a corresponding synchrotron self-absorbed magnetic field of B-SSA = (2.9 +/- 1.6) G, and an equipartition magnetic field of B-eq = (5.2 +/- 0.6) G. Three components are resolved with the highest fractional polarisation detected for this object (m(net) = (17.0 +/- 3.9)%). The positions of the components are compatible with those seen in low-frequency VLBI observations since 2017-2018. We report a steeply negative slope of the spectrum at 228 GHz. We used these findings to test existing models of jet formation, propagation, and Faraday rotation in 3C 84.Conclusions. The findings of our investigation into di fferent flow geometries and black hole spins support an advection-dominated accretion flow in a magnetically arrested state around a rapidly rotating supermassive black hole as a model of the jet-launching system in the core of 3C 84. However, systematic uncertainties due to the limited (u, v)-coverage, however, cannot be ignored. Our upcoming work using new EHT data, which offer full imaging capabilities, will shed more light on the compact region of 3C 84
    • ā€¦
    corecore