559 research outputs found
Impact of sex on timing and clinical outcome of septal myectomy for obstructive hypertrophic cardiomyopathy
Background: Sex disparities are common in hypertrophic cardiomyopathy (HCM). Previous research has shown that at time of myectomy, women are older, have greater impairment of diastolic function and more advanced cardiac remodeling. The clinical impact of these differences is unknown. Method: This study included 162 HCM patients (61% m
Radio-Excess IRAS Galaxies: PMN/FSC Sample Selection
A sample of 178 extragalactic objects is defined by correlating the 60 micron
IRAS FSC with the 5 GHz PMN catalog. Of these, 98 objects lie above the
radio/far-infrared relation for radio-quiet objects. These radio-excess
galaxies and quasars have a uniform distribution of radio excesses and appear
to be a new population of active galaxies not present in previous
radio/far-infrared samples. The radio-excess objects extend over the full range
of far-infrared luminosities seen in extragalactic objects. Objects with small
radio excesses are more likely to have far-infrared colors similar to
starbursts, while objects with large radio excesses have far-infrared colors
typical of pure AGN. Some of the most far-infrared luminous radio-excess
objects have the highest far-infrared optical depths. These are good candidates
to search for hidden broad line regions in polarized light or via near-infrared
spectroscopy. Some low far-infrared luminosity radio-excess objects appear to
derive a dominant fraction of their far-infrared emission from star formation,
despite the dominance of the AGN at radio wavelengths. Many of the radio-excess
objects have sizes likely to be smaller than the optical host, but show
optically thin radio emission. We draw parallels between these objects and high
radio luminosity Compact Steep-Spectrum (CSS) and GigaHertz Peaked-Spectrum
(GPS) objects. Radio sources with these characteristics may be young AGN in
which the radio activity has begun only recently. Alternatively, high central
densities in the host galaxies may be confining the radio sources to compact
sizes. We discuss future observations required to distinguish between these
possibilities and determine the nature of radio-excess objects.Comment: Submitted to AJ. 44 pages, 11 figures. A version of the paper with
higher quality figures is available from
http://www.mso.anu.edu.au/~cdrake/PMNFSC/paperI
Implementation of the CALM intervention for anxiety disorders: a qualitative study
<p>Abstract</p> <p>Background</p> <p>Investigators recently tested the effectiveness of a collaborative-care intervention for anxiety disorders: Coordinated Anxiety Learning and Management(CALM) []) in 17 primary care clinics around the United States. Investigators also conducted a qualitative process evaluation. Key research questions were as follows: (1) What were the facilitators/barriers to implementing CALM? (2) What were the facilitators/barriers to sustaining CALM after the study was completed?</p> <p>Methods</p> <p>Key informant interviews were conducted with 47 clinic staff members (18 primary care providers, 13 nurses, 8 clinic administrators, and 8 clinic staff) and 14 study-trained anxiety clinical specialists (ACSs) who coordinated the collaborative care and provided cognitive behavioral therapy. The interviews were semistructured and conducted by phone. Data were content analyzed with line-by-line analyses leading to the development and refinement of themes.</p> <p>Results</p> <p>Similar themes emerged across stakeholders. Important facilitators to implementation included the perception of "low burden" to implement, provider satisfaction with the intervention, and frequent provider interaction with ACSs. Barriers to implementation included variable provider interest in mental health, high rates of part-time providers in clinics, and high social stressors of lower socioeconomic-status patients interfering with adherence. Key sustainability facilitators were if a clinic had already incorporated collaborative care for another disorder and presence of onsite mental health staff. The main barrier to sustainability was funding for the ACS.</p> <p>Conclusions</p> <p>The CALM intervention was relatively easy to incorporate during the effectiveness trial, and satisfaction was generally high. Numerous implementation and sustainability barriers could limit the reach and impact of widespread adoption. Findings should be interpreted with the knowledge that the ACSs in this study were provided and trained by the study. Future research should explore uptake of CALM and similar interventions without the aid of an effectiveness trial.</p
Dark sectors 2016 Workshop: community report
This report, based on the Dark Sectors workshop at SLAC in April 2016,
summarizes the scientific importance of searches for dark sector dark matter
and forces at masses beneath the weak-scale, the status of this broad
international field, the important milestones motivating future exploration,
and promising experimental opportunities to reach these milestones over the
next 5-10 years
A prospective randomised, open-labeled, trial comparing sirolimus-containing versus mTOR-inhibitor-free immunosuppression in patients undergoing liver transplantation for hepatocellular carcinoma
<p>Abstract</p> <p>Background</p> <p>The potential anti-cancer effects of mammalian target of rapamycin (mTOR) inhibitors are being intensively studied. To date, however, few randomised clinical trials (RCT) have been performed to demonstrate anti-neoplastic effects in the pure oncology setting, and at present, no oncology endpoint-directed RCT has been reported in the high-malignancy risk population of immunosuppressed transplant recipients. Interestingly, since mTOR inhibitors have both immunosuppressive and anti-cancer effects, they have the potential to simultaneously protect against immunologic graft loss and tumour development. Therefore, we designed a prospective RCT to determine if the mTOR inhibitor sirolimus can improve hepatocellular carcinoma (HCC)-free patient survival in liver transplant (LT) recipients with a pre-transplant diagnosis of HCC.</p> <p>Methods/Design</p> <p>The study is an open-labelled, randomised, RCT comparing sirolimus-containing versus mTOR-inhibitor-free immunosuppression in patients undergoing LT for HCC. Patients with a histologically confirmed HCC diagnosis are randomised into 2 groups within 4-6 weeks after LT; one arm is maintained on a centre-specific mTOR-inhibitor-free immunosuppressive protocol and the second arm is maintained on a centre-specific mTOR-inhibitor-free immunosuppressive protocol for the first 4-6 weeks, at which time sirolimus is initiated. A 2<sup>1/2</sup> -year recruitment phase is planned with a 5-year follow-up, testing HCC-free survival as the primary endpoint. Our hypothesis is that sirolimus use in the second arm of the study will improve HCC-free survival. The study is a non-commercial investigator-initiated trial (IIT) sponsored by the University Hospital Regensburg and is endorsed by the European Liver and Intestine Transplant Association; 13 countries within Europe, Canada and Australia are participating.</p> <p>Discussion</p> <p>If our hypothesis is correct that mTOR inhibition can reduce HCC tumour growth while simultaneously providing immunosuppression to protect the liver allograft from rejection, patients should experience less post-transplant problems with HCC recurrence, and therefore could expect a longer and better quality of life. A positive outcome will likely change the standard of posttransplant immunosuppressive care for LT patients with HCC.</p> <p>Trial Register</p> <p>Trial registered at <url>http://www.clinicaltrials.gov</url>: NCT00355862</p> <p>(EudraCT Number: 2005-005362-36)</p
A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
Erratum to: Methods for evaluating medical tests and biomarkers
[This corrects the article DOI: 10.1186/s41512-016-0001-y.]
- …