340 research outputs found

    Understanding jumping to conclusions in patients with persecutory delusions: working memory and intolerance of uncertainty

    No full text
    Background. Persecutory delusions are a key psychotic experience. A reasoning style known as ‘jumping to conclusions’ (JTC) – limited information gathering before reaching certainty in decision making – has been identified as a contributory factor in the occurrence of delusions. The cognitive processes that underpin JTC need to be determined in order to develop effective interventions for delusions. In the current study two alternative perspectives were tested: that JTC partially results from impairment in information-processing capabilities and that JTC is a motivated strategy to avoid uncertainty.Method. A group of 123 patients with persistent persecutory delusions completed assessments of JTC (the 60:40 beads task), IQ, working memory, intolerance of uncertainty, and psychiatric symptoms. Patients showing JTC were compared with patients not showing JTC.Results. A total of 30 (24%) patients with delusions showed JTC. There were no differences between patients who did and did not jump to conclusions in overall psychopathology. Patients who jumped to conclusions had poorer working memory performance, lower IQ, lower intolerance of uncertainty and lower levels of worry.Working memory and worry independently predicted the presence of JTC.Conclusions. Hasty decision making in patients with delusions may partly arise from difficulties in keeping information in mind. Interventions for JTC are likely to benefit from addressing working memory performance, while in vivo techniques for patients with delusions will benefit from limiting the demands on working memory. The study provides little evidence for a contribution to JTC from top down motivational beliefs about uncertainty

    Investigations of meltwater refreezing and density variations in the snowpack and firn within the percolation zone of the Greenland Ice Sheet

    Get PDF
    The mass balance of polythermal ice masses is critically dependent on the proportion of surface-generated meltwater that subsequently refreezes in the snowpack and firn. In order to quantify this effect and to characterize its spatial variability, we measured near-surface (26%, resulting in a 32% increase in net accumulation. This 'seasonal densification' increased at lower elevations, rising to 47% 10 km closer to the ice-sheet margin at 1860 m a. s. l. Density/depth profiles from nine sites within 1 km2 at ∼1945 m a.s.l. reveal complex stratigraphies that change over short spatial scales and seasonally. We conclude that estimates of mass-balance change cannot be calculated solely from observed changes in surface elevation, but that near-surface densification must also be considered. However, predicting spatial and temporal variations in densification may not be straightforward. Further, the development of complex firn-density profiles both masks discernible annual layers in the near-surface firn and ice stratigraphy and is likely to introduce error into radar-derived estimates of surface elevation

    Recent loss of floating ice and the consequent sea level contribution

    Get PDF
    We combine new and published satellite observations and the results of a coupled ice-ocean model to provide the first estimate of changes in the quantity of ice floating in the global oceans and the consequent sea level contribution. Rapid losses of Arctic sea ice and small Antarctic ice shelves are partially offset by thickening of Antarctic sea ice and large Antarctic ice shelves. Altogether, 746 +/- 127 km(3) yr(-1) of floating ice was lost between 1994 and 2004, a value that exceeds considerably the reduction in grounded ice over the same period. Although the losses are equivalent to a small (49 +/- 8 μm yr(-1)) rise in mean sea level, there may be large regional variations in the degree of ocean freshening and mixing. Ice shelves at the Antarctic Peninsula and in the Amundsen Sea, for example, have lost 481 +/- 38 km(3) yr(-1)

    Monitoring the CMS strip tracker readout system

    Get PDF
    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

    Commissioning and Calibrating the CMS Silicon Strip Tracker

    Get PDF
    The data acquisition system for the CMS Silicon Strip Tracker (SST) is based around a custom analogue front-end ASIC, an analogue optical link system and an off-detector VME board that performs digitization, zero-suppression and data formatting. A complex procedure is required to optimally configure, calibrate and synchronize the 107 channels of the SST readout system. We present an overview of this procedure, which will be used to commission and calibrate the SST during the integration, Start-Up and operational phases of the experiment. Recent experiences from the CMS Magnet Test Cosmic Challenge and system tests at the Tracker Integration Facility are also reported

    Slepian functions and their use in signal estimation and spectral analysis

    Full text link
    It is a well-known fact that mathematical functions that are timelimited (or spacelimited) cannot be simultaneously bandlimited (in frequency). Yet the finite precision of measurement and computation unavoidably bandlimits our observation and modeling scientific data, and we often only have access to, or are only interested in, a study area that is temporally or spatially bounded. In the geosciences we may be interested in spectrally modeling a time series defined only on a certain interval, or we may want to characterize a specific geographical area observed using an effectively bandlimited measurement device. It is clear that analyzing and representing scientific data of this kind will be facilitated if a basis of functions can be found that are "spatiospectrally" concentrated, i.e. "localized" in both domains at the same time. Here, we give a theoretical overview of one particular approach to this "concentration" problem, as originally proposed for time series by Slepian and coworkers, in the 1960s. We show how this framework leads to practical algorithms and statistically performant methods for the analysis of signals and their power spectra in one and two dimensions, and on the surface of a sphere.Comment: Submitted to the Handbook of Geomathematics, edited by Willi Freeden, Zuhair M. Nashed and Thomas Sonar, and to be published by Springer Verla

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Scalar and vector Slepian functions, spherical signal estimation and spectral analysis

    Full text link
    It is a well-known fact that mathematical functions that are timelimited (or spacelimited) cannot be simultaneously bandlimited (in frequency). Yet the finite precision of measurement and computation unavoidably bandlimits our observation and modeling scientific data, and we often only have access to, or are only interested in, a study area that is temporally or spatially bounded. In the geosciences we may be interested in spectrally modeling a time series defined only on a certain interval, or we may want to characterize a specific geographical area observed using an effectively bandlimited measurement device. It is clear that analyzing and representing scientific data of this kind will be facilitated if a basis of functions can be found that are "spatiospectrally" concentrated, i.e. "localized" in both domains at the same time. Here, we give a theoretical overview of one particular approach to this "concentration" problem, as originally proposed for time series by Slepian and coworkers, in the 1960s. We show how this framework leads to practical algorithms and statistically performant methods for the analysis of signals and their power spectra in one and two dimensions, and, particularly for applications in the geosciences, for scalar and vectorial signals defined on the surface of a unit sphere.Comment: Submitted to the 2nd Edition of the Handbook of Geomathematics, edited by Willi Freeden, Zuhair M. Nashed and Thomas Sonar, and to be published by Springer Verlag. This is a slightly modified but expanded version of the paper arxiv:0909.5368 that appeared in the 1st Edition of the Handbook, when it was called: Slepian functions and their use in signal estimation and spectral analysi

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Sexual Size Dimorphism and Body Condition in the Australasian Gannet

    Get PDF
    Funding: The research was financially supported by the Holsworth Wildlife Research Endowment. Acknowledgments We thank the Victorian Marine Science Consortium, Sea All Dolphin Swim, Parks Victoria, and the Point Danger Management Committee for logistical support. We are grateful for the assistance of the many field volunteers involved in the study.Peer reviewedPublisher PD
    corecore