308 research outputs found
Structural nanotechnology: Three-dimensional cryo-EM and its use in the development of nanoplatforms for: In vitro catalysis
The organization of enzymes into different subcellular compartments is essential for correct cell function. Protein-based cages are a relatively recently discovered subclass of structurally dynamic cellular compartments that can be mimicked in the laboratory to encapsulate enzymes. These synthetic structures can then be used to improve our understanding of natural protein-based cages, or as nanoreactors in industrial catalysis, metabolic engineering, and medicine. Since the function of natural protein-based cages is related to their three-dimensional structure, it is important to determine this at the highest possible resolution if viable nanoreactors are to be engineered. Cryo-electron microscopy (cryo-EM) is ideal for undertaking such analyses within a feasible time frame and at near-native conditions. This review describes how three-dimensional cryo-EM is used in this field and discusses its advantages. An overview is also given of the nanoreactors produced so far, their structure, function, and applications
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
Performance and Operation of the CMS Electromagnetic Calorimeter
The operation and general performance of the CMS electromagnetic calorimeter
using cosmic-ray muons are described. These muons were recorded after the
closure of the CMS detector in late 2008. The calorimeter is made of lead
tungstate crystals and the overall status of the 75848 channels corresponding
to the barrel and endcap detectors is reported. The stability of crucial
operational parameters, such as high voltage, temperature and electronic noise,
is summarised and the performance of the light monitoring system is presented
General practitioners' beliefs about effectiveness and intentions to recommend smoking cessation services: qualitative and quantitative studies
Background: General practitioners' (GPs) negative beliefs about nicotine dependence medications may act as barriers to prescribing them. Methods: Study 1: Twenty-five GPs from 16 practices across London were interviewed in this qualitative study. Framework analysis was used to identify key themes. Study 2: A convenience sample of 367 GPs completed an internet-based survey. Path-analysis was used to examine the relations between beliefs and intentions to prescribe smoking cessation medications. Results: Study 1: Whilst nicotine replacement therapy (NRT) and bupropion were generally perceived as effective and cost-effective, the effectiveness of NRT was seen as critically dependent on behavioural support for smoking cessation. This dependence appeared to be influenced by perceptions that without support smokers would neglect psychological aspects of smoking and use NRT incorrectly. GPs perceived bupropion as dangerous and were concerned about its side-effects. Study 2: GPs' beliefs had medium ( NRT, f(2) =.23) to large ( bupropion, f(2)=. 45; NRT without support, f(2)=. 59) effects on their intentions to prescribe medications. Beliefs about effectiveness of NRT and bupropion and the perceived danger of bupropion were the key predictors of intentions to prescribe NRT and bupropion, respectively. Beliefs about neglecting psychological aspects of smoking and incorrect use had indirect effects on intentions to prescribe NRT without support, operating via beliefs about effectiveness. Conclusion: GPs vary in their beliefs about the effectiveness and safety of smoking cessation medications. Their intentions to prescribe these medications vary in line with these beliefs. Interventions aimed at increasing the likelihood with which GPs prescribe these medications may be more effective if they addressed these belief
HIV infection and sexual risk among men who have sex with men and women (MSMW): A systematic review and meta-analysis
Objectives: To estimate the number of men who have sex with men and women who are HIV-positive in the United States, and to compare HIV prevalence rates between men who have sex with men and women, men who have sex with men only, and men who have sex with women exclusively. Methods: Following PRISMA guidelines, we conducted a systematic review and meta-analysis of reports referencing HIV prevalence and men who have sex with men and women. We searched PubMed and Ovid PsycINFO for peer-reviewed, U.S.-based articles reporting on HIV prevalence among men who have sex with men and women. We conducted event rate, effect size, moderation and sensitivity analyses. Results: We estimate that 1.0% of U.S. males are bisexually-behaving, and that 121,800 bisexually-behaving men are HIV-positive. Men who have sex with men and women are less than half as likely to be HIV-positive as men who have sex with men only (16.9% vs. 33.3%; OR = 0.41, 95% CI: 0.31, 0.54), but more than five times as likely to be HIV-positive as men who have sex with women exclusively (18.3% vs. 3.5%; OR = 5.71, 95% CI: 3.47, 9.39). They are less likely to engage in unprotected receptive anal intercourse than men who have sex with men only (15.9% vs. 35.0%; OR = 0.36, 95% CI: 0.28, 0.46). Men who have sex with men and women in samples with high racial/ethnic minority proportions had significantly higher HIV prevalence than their counterparts in low racial/ethnic minority samples. Conclusions: This represents the first meta-analysis of HIV prevalence in the U.S. between men who have sex with men and women and men who have sex with men only. Data collection, research, and HIV prevention and care delivery specifically tailored to men who have sex with men and women are necessary to better quantify and ameliorate this population's HIV burden. © 2014 Friedman et al
Collision Mortality Has No Discernible Effect on Population Trends of North American Birds
Avian biodiversity is threatened by numerous anthropogenic factors and migratory species are especially at risk. Migrating birds frequently collide with manmade structures and such losses are believed to represent the majority of anthropogenic mortality for North American birds. However, estimates of total collision mortality range across several orders of magnitude and effects on population dynamics remain unknown. Herein, we develop a novel method to assess relative vulnerability to anthropogenic threats, which we demonstrate using 243,103 collision records from 188 species of eastern North American landbirds. After correcting mortality estimates for variation attributable to population size and geographic overlap with potential collision structures, we found that per capita vulnerability to collision with buildings and towers varied over more than four orders of magnitude among species. Species that migrate long distances or at night were much more likely to be killed by collisions than year-round residents or diurnal migrants. However, there was no correlation between relative collision mortality and long-term population trends for these same species. Thus, although millions of North American birds are killed annually by collisions with manmade structures, this source of mortality has no discernible effect on populations
Structural Characterization of Native and Modified Encapsulins as Nanoplatforms for in Vitro Catalysis and Cellular Uptake
Recent years have witnessed the emergence of bacterial semiorganelle encapsulins as promising platforms for bio-nanotechnology. To advance the development of encapsulins as nanoplatforms, a functional and structural basis of these assemblies is required. Encapsulin from Brevibacterium linens is known to be a protein-based vessel for an enzyme cargo in its cavity, which could be replaced with a foreign cargo, resulting in a modified encapsulin. Here, we characterize the native structure of B. linens encapsulins with both native and foreign cargo using cryo-electron microscopy (cryo-EM). Furthermore, by harnessing the confined enzyme (i.e., a peroxidase), we demonstrate the functionality of the encapsulin for an in vitro surface-immobilized catalysis in a cascade pathway with an additional enzyme, glucose oxidase. We also demonstrate the in vivo functionality of the encapsulin for cellular uptake using mammalian macrophages. Unraveling both the structure and functionality of the encapsulins allows transforming biological nanocompartments into functional systems
Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter
VertaisarvioitupeerReviewe
Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns
Inter-observer variability of visual analysis of “stress”-only adenosine first-pass myocardial perfusion imaging in relation to clinical experience and reading criteria
To assess the inter-observer agreement of adenosine “stress”-only visual analysis of perfusion MR images in relation to experience and reading criteria. 106 adenosine perfusion MR examinations out of 350, 46 consecutive positive examinations and 60 randomly selected negative examinations were visually analysed by three individual readers (two residents and a technician) with different levels of experience. Readings (blinded for any information) were compared with the reading of an expert radiologist. After a month the examinations were presented again (randomly) without knowledge regarding the first readings. This time readings were performed with the systematical use of reading criteria. Agreement with the expert reading was good for the most experienced resident (k = 0.88). Kappa was 0.48 for the least experienced, and 0.57 for the technician. After the second systematical reading inter-observer agreement increased to 0.9, 0.68 and 0.77 respectively. Overall kappa increased from 0.59 to 0.71. The use of reading criteria significantly improved the performance of the least experienced reader (P = 0.01). Visual analysis of adenosine “stress”-only first-pass perfusion MR images has moderate to very good agreement. Performance is experience related, but the systematic use of reading criteria significantly increased performance for the least experienced observer
- …
