4,373 research outputs found
Comparison of anticoagulation quality between acenocoumarol and warfarin in patients with mechanical prosthetic heart valves. insights from the nationwide plectrum study
Vitamin K antagonists are indicated for the thromboprophylaxis in patients with mechanical prosthetic heart valves (MPHV). However, it is unclear whether some differences between acenocoumarol and warfarin in terms of anticoagulation quality do exist. We included 2111 MPHV patients included in the nationwide PLECTRUM registry. We evaluated anticoagulation quality by the time in therapeutic range (TiTR). Factors associated with acenocoumarol use and with low TiTR were investigated by multivariable logistic regression analysis. Mean age was 56.8 Âą 12.3 years; 44.6% of patients were women and 395 patients were on acenocoumarol. A multivariable logistic regression analysis showed that patients on acenocoumarol had more comorbidities (i.e., âĽ3, odds ratio (OR) 1.443, 95% confidence interval (CI) 1.081-1.927, p = 0.013). The mean TiTR was lower in the acenocoumarol than in the warfarin group (56.1 Âą 19.2% vs. 61.6 Âą 19.4%, p < 0.001). A higher prevalence of TiTR (<60%, <65%, or <70%) was found in acenocoumarol users than in warfarin ones (p < 0.001 for all comparisons). Acenocoumarol use was associated with low TiTR regardless of the cutoff used at multivariable analysis. A lower TiTR on acenocoumarol was found in all subgroups of patients analyzed according to sex, hypertension, diabetes, age, valve site, atrial fibrillation, and INR range. In conclusion, anticoagulation quality was consistently lower in MPHV patients on acenocoumarol compared to those on warfarin
Statin liver safety in non-alcoholic fatty liver disease: A systematic review and metanalysis
Aims Statin liver safety in non-alcoholic fatty liver disease (NAFLD) patients is not well defined. We analysed differences in liver function tests, including alanine transaminase aminotransferase (ALT), aspartate transaminase (AST) and gamma-glutamyl transpeptidase (GGT) in NAFLD patients treated or not treated with statins. Methods We performed a systematic review of MEDLINE via PubMed and EMBASE databases and metanalysis of clinical studies investigating levels of ALT, AST and GGT in NAFLD according to statin treatment. Mean difference (MD) and percentage MD were calculated between the two groups. Results We included 22 studies with 2345 NAFLD patients. Overall, 16 were before-after interventional, five were cross-sectional and one was combined cross-sectional/interventional study. In all interventional studies, except one, patients had raised ALT, AST and GGT at baseline. Interventional studies showed reduced ALT values with an MD reduction of -27.2 U/L (95% CI -35.25/-19.15) and a percentage MD reduction of -35.41% (95% CI -44.78/-26.04). Also, AST values were reduced after statin treatment in interventional studies with an MD of -18.82 U/L (95% CI -25.63/-12.02) (percentage -31.78%, 95% CI -41.45/-22.11). Similarly, GGT levels were reduced after statin treatment with an MD of -19.93 U/L (95% CI -27.10/-12.77) (percentage -25.57%, 95% CI -35.18/-15.97). Cross-sectional studies showed no difference in AST and GGT values between patients treated with and without statins. Conclusion In interventional studies, ALT, AST and GGT were reduced after statin treatment with a percentage mean difference of -35.41%, -31.78% and -25.57%, respectively, while observational studies showed a null effect, suggesting liver safety of statins in NAFLD patients
A pulsed nanosecond IR laser diode system to automatically test the Single Event Effects in the laboratory
Abstract A pulsed nanosecond IR laser diode system to automatically test the Single Event Effects in laboratory is described. The results of Single Event Latchup (SEL) test on two VLSI chips (VA_HDR64, 0.8 and 1.2 Îźm technology) are discussed and compared to those obtained with high-energy heavy ions at GSI (Darmstadt)
Recommended from our members
Lowâcost flexible thinâfilm detector for medical dosimetry applications
The purpose of this study is to characterize dosimetric properties of thin film photovoltaic sensors as a platform for development of prototype dose verification equipment in radiotherapy. Towards this goal, flexible thinâfilm sensors of dose with embedded data acquisition electronics and wireless data transmission are prototyped and tested in kV and MV photon beams. Fundamental dosimetric properties are determined in view of a specific application to dose verification in multiple planes or curved surfaces inside a phantom. Uniqueness of the new thinâfilm sensors consists in their mechanical properties, lowâpower operation, and lowâcost. They are thinner and more flexible than dosimetric films. In principle, each thinâfilm sensor can be fabricated in any size (mm2 â cm2 areas) and shape. Individual sensors can be put together in an array of sensors spreading over large areas and yet being light. Photovoltaic mode of charge collection (of electrons and holes) does not require external electric field applied to the sensor, and this implies simplicity of data acquisition electronics and low power operation. The prototype device use for testing consists of several thin film dose sensors, each of about 1.5 cmĂ5 cm area, connected to simple readout electronics. Sensitivity of the sensors is determined per unit area and compared to EPID sensitivity, as well as other standard photodiodes. Each sensor independently measures dose and is based on commercially available flexible thinâfilm aSi photodiodes. Readout electronics consists of an ultra lowâpower microcontroller, radio frequency transmitter, and a lowânoise amplification circuit implemented on a flexible printed circuit board. Detector output is digitized and transmitted wirelessly to an external host computer where it is integrated and processed. A megavoltage medical linear accelerator (Varian Tx) equipped with kilovoltage online imaging system and a Cobalt source are use to irradiate different thinâfilm detector sensors in a Solid Water phantom under various irradiation conditions. Different factors are considered in characterization of the device attributes: energies (80 kVp, 130 kVp, 6 MV, 15 MV), dose rates (different ms Ă mA, 100â600 MU/min), total doses (0.1 cGyâ500 cGy), depths (0.5 cmâ20 cm), irradiation angles with respect to the detector surface (0°â180°), and IMRT tests (closed MLC, sweeping gap). The detector response to MV radiation is both linear with total dose (~1â400 cGy) and independent of dose rate (100â600 Mu/min). The sensitivity per unit area of thinâfilm sensors is lower than for aSi flatâpanel detectors, but sufficient to acquire stable and accurate signals during irradiations. The proposed thinâfilm photodiode system has properties which make it promising for clinical dosimetry. Due to the mechanical flexibility of each sensor and readout electronics, lowâcost, and wireless data acquisition, it could be considered for quality assurance (e.g., IMRT, mechanical linac QA), as well as realâtime dose monitoring in challenging setup configurations, including large area and 3D detection (multiple planes or curved surfaces). PACS number: 87.56.F
Protons in near earth orbit
The proton spectrum in the kinetic energy range 0.1 to 200 GeV was measured
by the Alpha Magnetic Spectrometer (AMS) during space shuttle flight STS-91 at
an altitude of 380 km. Above the geomagnetic cutoff the observed spectrum is
parameterized by a power law. Below the geomagnetic cutoff a substantial second
spectrum was observed concentrated at equatorial latitudes with a flux ~ 70
m^-2 sec^-1 sr^-1. Most of these second spectrum protons follow a complicated
trajectory and originate from a restricted geographic region.Comment: 19 pages, Latex, 7 .eps figure
Search for antihelium in cosmic rays
The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle
Discovery during flight STS-91 in a 51.7 degree orbit at altitudes between 320
and 390 km. A total of 2.86 * 10^6 helium nuclei were observed in the rigidity
range 1 to 140 GV. No antihelium nuclei were detected at any rigidity. An upper
limit on the flux ratio of antihelium to helium of < 1.1 * 10^-6 is obtained.Comment: 18 pages, Latex, 9 .eps figure
A Study of Cosmic Ray Secondaries Induced by the Mir Space Station Using AMS-01
The Alpha Magnetic Spectrometer (AMS-02) is a high energy particle physics
experiment that will study cosmic rays in the to range and will be installed on the International Space Station
(ISS) for at least 3 years. A first version of AMS-02, AMS-01, flew aboard the
space shuttle \emph{Discovery} from June 2 to June 12, 1998, and collected
cosmic ray triggers. Part of the \emph{Mir} space station was within the
AMS-01 field of view during the four day \emph{Mir} docking phase of this
flight. We have reconstructed an image of this part of the \emph{Mir} space
station using secondary and emissions from primary cosmic rays
interacting with \emph{Mir}. This is the first time this reconstruction was
performed in AMS-01, and it is important for understanding potential
backgrounds during the 3 year AMS-02 mission.Comment: To be submitted to NIM B Added material requested by referee. Minor
stylistic and grammer change
Search for New Physics with Jets and Missing Transverse Momentum in pp collisions at sqrt(s) = 7 TeV
A search for new physics is presented based on an event signature of at least
three jets accompanied by large missing transverse momentum, using a data
sample corresponding to an integrated luminosity of 36 inverse picobarns
collected in proton--proton collisions at sqrt(s)=7 TeV with the CMS detector
at the LHC. No excess of events is observed above the expected standard model
backgrounds, which are all estimated from the data. Exclusion limits are
presented for the constrained minimal supersymmetric extension of the standard
model. Cross section limits are also presented using simplified models with new
particles decaying to an undetected particle and one or two jets
Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV
A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay
channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7
TeV is presented. The data were collected at the LHC, with the CMS detector,
and correspond to an integrated luminosity of 4.6 inverse femtobarns. No
significant excess is observed above the background expectation, and upper
limits are set on the Higgs boson production cross section. The presence of the
standard model Higgs boson with a mass in the 270-440 GeV range is excluded at
95% confidence level.Comment: Submitted to JHE
- âŚ