336 research outputs found
Conductive Cooling of SDD and SSD Front-End Chips for ALICE
We present analysis, technology developments and test results of the heat drain system of the SDD and SSD front-end electronics for the ALICE Inner Tracker System (ITS). Application of super thermoconductive carbon fibre thin plates provides a practical solution for the development of miniature motherboards for the FEE chips situated inside the sensitive ITS volume. Unidirectional carbon fibre motherboards of 160 -300 micron thickness ensure the mounting of the FEE chips and an efficient heat sink to the cooling arteries. Thermal conductivity up to 1.3 times better than copper is achieved while preserving a negligible multiple scattering contribution by the material (less than 0.15 percent of X/Xo)
Test and commissioning of the CARLOS control boards for the ALICE Silicon Drift Detectors
This paper presents the test strategy employed during the installation of the CARLOS end ladder boards developed for the Silicon Drift Detectors (SDD) of ALICE. Each CARLOS board compresses the data provided by the front-end electronics of one SDD and sends them via an optical link of 800 Mbit/s to the data concentrator card (CARLOSrx) located in the counting room. The paper describes the integration of the CARLOS boards in the final SDD system, including its cooling and mechanical support, the power supply distribution and the optical interconnections. The results of the tests performed after each step of the installation sequence are reported
Obuolinio pjūklelio (Hoplocampa testudinea Klug) populiacijos tankis ir žalingumas soduose Lietuvoje, įvairių veislių obelis auginant pagal dvi ūkininkavimo sistemas
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR
Simulation results for future measurements of electromagnetic proton form
factors at \PANDA (FAIR) within the PandaRoot software framework are reported.
The statistical precision with which the proton form factors can be determined
is estimated. The signal channel is studied on the basis
of two different but consistent procedures. The suppression of the main
background channel, , is studied.
Furthermore, the background versus signal efficiency, statistical and
systematical uncertainties on the extracted proton form factors are evaluated
using two different procedures. The results are consistent with those of a
previous simulation study using an older, simplified framework. However, a
slightly better precision is achieved in the PandaRoot study in a large range
of momentum transfer, assuming the nominal beam conditions and detector
performance
Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV
We report the first measurement of charged particle elliptic flow in Pb-Pb
collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron
Collider. The measurement is performed in the central pseudorapidity region
(||<0.8) and transverse momentum range 0.2< < 5.0 GeV/. The
elliptic flow signal v, measured using the 4-particle correlation method,
averaged over transverse momentum and pseudorapidity is 0.087 0.002
(stat) 0.004 (syst) in the 40-50% centrality class. The differential
elliptic flow v reaches a maximum of 0.2 near = 3
GeV/. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow
increases by about 30%. Some hydrodynamic model predictions which include
viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/389
Embarazo exitoso en paciente con hemodiafiltración on-line de alto volumen predilucional: ¿la mejor opción dialítica en mujeres con enfermedad renal crónica y embarazo?
Suppression of charged particle production at large transverse momentum in central Pb-Pb collisions at TeV
Inclusive transverse momentum spectra of primary charged particles in Pb-Pb
collisions at = 2.76 TeV have been measured by the ALICE
Collaboration at the LHC. The data are presented for central and peripheral
collisions, corresponding to 0-5% and 70-80% of the hadronic Pb-Pb cross
section. The measured charged particle spectra in and GeV/ are compared to the expectation in pp collisions at the same
, scaled by the number of underlying nucleon-nucleon
collisions. The comparison is expressed in terms of the nuclear modification
factor . The result indicates only weak medium effects ( 0.7) in peripheral collisions. In central collisions,
reaches a minimum of about 0.14 at -7GeV/ and increases
significantly at larger . The measured suppression of high- particles is stronger than that observed at lower collision energies,
indicating that a very dense medium is formed in central Pb-Pb collisions at
the LHC.Comment: 15 pages, 5 captioned figures, 3 tables, authors from page 10,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/98
Two-pion Bose-Einstein correlations in central Pb-Pb collisions at = 2.76 TeV
The first measurement of two-pion Bose-Einstein correlations in central Pb-Pb
collisions at TeV at the Large Hadron Collider is
presented. We observe a growing trend with energy now not only for the
longitudinal and the outward but also for the sideward pion source radius. The
pion homogeneity volume and the decoupling time are significantly larger than
those measured at RHIC.Comment: 17 pages, 5 captioned figures, 1 table, authors from page 12,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/388
Galectin-3 immunodetection in follicular thyroid neoplasms: a prospective study on fine-needle aspiration samples
Fine-needle aspiration cytology, which is well established to be accurate for the diagnosis of thyroid cancer, may be inconclusive for the follicular thyroid neoplasms. As galectin-3 was suggested to be a marker of malignant thyrocytes, we investigated whether this protein might be helpful in the diagnosis of aspirates classified as undeterminate by cytology. After establishing an easy processing of aspirates for galectin-3 immunodetection, a series of aspirates categorised as benign (n=63), malignant (n=17) or undeterminate (n=34) was prospectively analysed for galectin-3. Only the patients with malignant or undeterminate lesions underwent surgery. Most lesions (86%) diagnosed as malignant by cytology or after surgery were positive for galectin-3. The majority of lesions (94%) classified as benign by cytology or after surgery was negative for galectin-3. The positive and negative predictive values were 83 and 95%, respectively. When focusing on the undeterminate lesions, the sensitivity and specificity were 75 and 90%, respectively, while the positive and negative predictive values were 82 and 87%, respectively. The specificity and the positive predictive value were higher (100%) when considering the percentage of stained cells. Altogether these results show that galectin-3 constitutes a useful marker in the diagnosis of thyroid lesions classified as undeterminate by conventional cytology
- …