670 research outputs found

    LONG-TERM INTRAOCULAR PRESSURE AFTER UNCOMPLICATED PARS PLANA VITRECTOMY FOR IDIOPATHIC EPIRETINAL MEMBRANE

    Get PDF
    \u2019Purrpose: To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Methods: Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the fi nal follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. Results: The median follow-up period was 36 months (range 12 \u2013 92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% con fi dence interval) statis- tically signi fi cant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not signi fi cant 0.2-mmHg ( 2 0.1 mmHg; 0.4 mmHg, 95% con fi dence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% con fi dence interval) without difference between the treated eyes and the group control. No signi fi cant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instru- ments was detected. Only patient \u2019 sagewassigni fi cantly higher (mean difference 4.2 years; 0.1 \u2013 8.0 years, Monte Carlo, 95% con fi dence interval) in those who de veloped late-onset ocular hypertension in the vitrectomized eye. Conclusion: Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.

    Profile of a new extended range-of-vision IOL: a laboratory study

    Get PDF
    Purpose To evaluate the surface profile of a new-generation extended range-of-vision intraocular lens (IOL) and to compare it with that obtained for a monofocal IOL based on the same platform. Methods Prospective, experimental, laboratory study comparing the surface profile of the DFT015 (AcrySof IQ Vivity; Alcon Laboratories, Inc.), a new-generation presbyopia-correcting IOL, with the profile of the SN60WF (AcrySof IQ; Alcon Laboratories, Inc.), an aspheric monofocal IOL based on the same platform. Raw profiles were obtained using contact profilometry. The best-fit form was then subtracted from each raw profile to highlight potential differences. Results No significant differences were appreciated in raw profiles. On the contrary, after form removal, the new extended range-of-vision IOL showed a peculiar profile characterized by the presence of two altitudinal symmetrical changes in the order of 1 µm, localized in the central portion of the optic. Conclusions The new-generation extended range-of-vision IOL evaluated showed a smooth change of its surface compared to the same platform monofocal IOL. The altitudinal changes blended in the central design of the new presbyopia-correcting IOL, although micrometric, might play a crucial role in creating a continuous focal range while minimizing visual disturbances.Open access funding provided by Università degli Studi di Trieste within the CRUI-CARE Agreement

    Effects of Social Conditions in a Virtual Exergame for Cognitive Rehabilitation in Multiple Sclerosis

    Get PDF
    Rehabilitation is essential for individuals with multiple sclerosis (MS) to improve their quality of life and mitigate the progression of the disease. Cognitive deficits, which commonly affect MS patients, significantly impact daily functioning and well-being. This paper focuses on the development of a digital version of the Tangram puzzle using virtual reality (VR) to promote logical reasoning, attention, and social interactions to enhance engagement in cognitive rehabilitation for MS patients. The developed simulation integrates social presence in the form of a non-playable character (NPC) intending to improve player performance and motivation to ultimately promote engagement and adherence to treatment. A user study involving different game modes with the NPC in either a supporting or interfering role, was conducted to evaluate the effectiveness and usability of the Tangram VR exergame. After collecting and analyzing questionnaire scores and performance data, our results suggest that the application was well-received by users, and the introduction of an NPC had an impact in terms of execution times and sense of frustration, depending on its behaviour. Nonetheless, only a limited set of significant differences between modes was found, suggesting that further study is necessary to validate the results fully

    Impact of Epiretinal Membrane on Optical Coherence Tomography Tools Used for Monitoring Glaucoma

    Get PDF
    Background: Retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL) measurements can be influenced by many factors including the presence of concomitant retinal diseases. The aim of this study it to assess the impact of epiretinal membrane (ERM) on RNFL and GCL assessment using optical coherence tomography (OCT). Methods: GCL, peripapillary RNFL (pRNFL), and Bruch's Membrane Opening Minimum Rim Width (BMO-MRW) thicknesses were analysed using an SD-OCT (Spectralis OCT) in eyes with idiopathic ERM and compared with a control group. Results: 161 eyes were included, 73 eyes in the control group and 88 eyes with idiopathic ERM. The pRNFL analysis revealed a statistically significant difference between the two groups in overall and temporal sector thicknesses. For GCL thickness report, the percentage of scans in which the GCL was erroneously segmented by automatic segmentation was assessed for each eye. A statistically significant difference was found in all sectors (p < 0.001), with the exception of external nasal sector. A statistically significant difference (p < 0.001) in the GCL total volume report was found in ERM group compared to the control group. For MRW at BMO analysis, there was no statistically significant difference in MRW thickness in any sector. Conclusion: In eyes with ERM, the GCL and pRNFL analysis seemed affected by the morphological retinal layers' modification. MRW-BMO did not appear to be directly affected by the presence of ERM

    Rebound Tonometry in Cataract Surgery: Comparison with Goldmann Applanation Tonometry

    Get PDF
    Purpose: to compare the rebound tonometer ICare\uae (RT) with the Goldmann applanation tonometer (GAT) in cataract surgery and to assess the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements. Design: retrospective, comparative study. Methods: a total of 472 patients underwent IOP measurement using RT (time 0 = RTa). GAT IOP measurement was performed 5 minutes later, followed by a second RT IOP measurement after other 5 minutes (RTa + 10 min = RTb). CCT was obtained by ultrasound pachymetry. In 106 patients IOP was measured by means of RT and GAT before clear corneal cataract surgery (RT1 and GAT1) and at one day postoperatively (RT2 and GAT2). Results: RT IOP values > 5 mmHg were overestimated, while RT IOP values < 15 mmHg were underestimated. Every 100 \ub5m of CCT an increase of 0.97 mmHg and 0.33 mmHg was found for RT and GAT respectively. The difference between RT1 and RT2, GAT1 and GAT2, RT1 and GAT1 was not statistically significant; while the difference between RT2 and GAT2 was statistically significant (p < 0.04). The difference between RTa and RTb was not statistically significant whereas the difference between RTa and GAT and RTb and GAT was statistically significant (p < 0.001). Conclusion: our results showed a good agreement between measurements obtained with RT and GAT in pre and postoperative cataract surgery, although a significant statistically difference was found between RT and GAT measurements performed postoperatively. Moreover, CCT is a parameter to be considered for the IOP measurement, especially for values obtained with RT

    Rethinking Elective Cataract Surgery Diagnostics, Assessments, and Tools after the COVID-19 Pandemic Experience and Beyond: Insights from the EUROCOVCAT Group

    Get PDF
    The progressive deterioration of the visual function in patients on waiting lists for cataract surgery has a negative impact on their quality of life, especially in the elderly population. Patient waiting times for cataract surgeries in many healthcare settings have increased recently due to the prolonged stop or slowdown of elective cataract surgery as a result of coronavirus disease 19 (COVID-19). The aim of this review is to highlight the impact of such a "de-prioritization" of cataract surgery and to summarize some critical issues and useful hints on how to reorganize cataract pathways, with a special focus on perioperative diagnostic tools during the recovery phase and beyond. The experiences of a group of surgeons originating from nine different countries, named the European COVID-19 Cataract Group (EUROCOVCAT), have been combined with the literature and recommendations from scientific ophthalmic societies and healthcare institutions. Key considerations for elective cataract surgery should include the reduction of the number of unnecessary visits and examinations, adoption of precautionary measures, and implementation of telemedicine instruments. New strategies should be adopted to provide an adequate level of assistance and to guarantee safety conditions. Flexibility will be the watchword and regular updates would be necessary following scientific insights and the development of the pandemic

    Production of He-4 and (4) in Pb-Pb collisions at root(NN)-N-S=2.76 TeV at the LHC

    Get PDF
    Results on the production of He-4 and (4) nuclei in Pb-Pb collisions at root(NN)-N-S = 2.76 TeV in the rapidity range vertical bar y vertical bar <1, using the ALICE detector, are presented in this paper. The rapidity densities corresponding to 0-10% central events are found to be dN/dy4(He) = (0.8 +/- 0.4 (stat) +/- 0.3 (syst)) x 10(-6) and dN/dy4 = (1.1 +/- 0.4 (stat) +/- 0.2 (syst)) x 10(-6), respectively. This is in agreement with the statistical thermal model expectation assuming the same chemical freeze-out temperature (T-chem = 156 MeV) as for light hadrons. The measured ratio of (4)/He-4 is 1.4 +/- 0.8 (stat) +/- 0.5 (syst). (C) 2018 Published by Elsevier B.V.Peer reviewe

    Long-range angular correlations on the near and away side in p&#8211;Pb collisions at

    Get PDF

    Azimuthal anisotropy of charged jet production in root s(NN)=2.76 TeV Pb-Pb collisions

    Get PDF
    We present measurements of the azimuthal dependence of charged jet production in central and semi-central root s(NN) = 2.76 TeV Pb-Pb collisions with respect to the second harmonic event plane, quantified as nu(ch)(2) (jet). Jet finding is performed employing the anti-k(T) algorithm with a resolution parameter R = 0.2 using charged tracks from the ALICE tracking system. The contribution of the azimuthal anisotropy of the underlying event is taken into account event-by-event. The remaining (statistical) region-to-region fluctuations are removed on an ensemble basis by unfolding the jet spectra for different event plane orientations independently. Significant non-zero nu(ch)(2) (jet) is observed in semi-central collisions (30-50% centrality) for 20 <p(T)(ch) (jet) <90 GeV/c. The azimuthal dependence of the charged jet production is similar to the dependence observed for jets comprising both charged and neutral fragments, and compatible with measurements of the nu(2) of single charged particles at high p(T). Good agreement between the data and predictions from JEWEL, an event generator simulating parton shower evolution in the presence of a dense QCD medium, is found in semi-central collisions. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).Peer reviewe

    Forward-central two-particle correlations in p-Pb collisions at root s(NN)=5.02 TeV

    Get PDF
    Two-particle angular correlations between trigger particles in the forward pseudorapidity range (2.5 2GeV/c. (C) 2015 CERN for the benefit of the ALICE Collaboration. Published by Elsevier B. V.Peer reviewe
    corecore