137 research outputs found

    PSN3 MANAGEMENT AND SOCIO ECONOMIC IMPACT OF ATOPIC DERMATITIS (AD) IN FRANCE:THE ELIPANEL STUDY

    Get PDF

    Measurement of the Z/gamma* + b-jet cross section in pp collisions at 7 TeV

    Get PDF
    The production of b jets in association with a Z/gamma* boson is studied using proton-proton collisions delivered by the LHC at a centre-of-mass energy of 7 TeV and recorded by the CMS detector. The inclusive cross section for Z/gamma* + b-jet production is measured in a sample corresponding to an integrated luminosity of 2.2 inverse femtobarns. The Z/gamma* + b-jet cross section with Z/gamma* to ll (where ll = ee or mu mu) for events with the invariant mass 60 < M(ll) < 120 GeV, at least one b jet at the hadron level with pT > 25 GeV and abs(eta) < 2.1, and a separation between the leptons and the jets of Delta R > 0.5 is found to be 5.84 +/- 0.08 (stat.) +/- 0.72 (syst.) +(0.25)/-(0.55) (theory) pb. The kinematic properties of the events are also studied and found to be in agreement with the predictions made by the MadGraph event generator with the parton shower and the hadronisation performed by PYTHIA.Comment: Submitted to the Journal of High Energy Physic

    coreNASH: Multi-stakeholder Consensus on Core Outcomes for Decision Making About Nonalcoholic Steatohepatitis Treatment

    Get PDF
    The increasing prevalence and burden of nonalcoholic steatohepatitis (NASH) has spurred the development of new treatments and a need to consider outcomes used for NASH treatment decision making. Development of a NASH core outcome set (COS) can help prioritize outcomes of highest importance by incorporating the perspectives from a variety of decision makers. coreNASH was an initiative to develop a COS for NASH using a modified Delphi consensus process with a multi-stakeholder voting panel. A candidate outcome list was created based on a literature review and key informant interviews. The candidate outcome list was then condensed and prioritized through three rounds of online voting and through discussion at an in-person meeting. Outcomes were retained or eliminated based on predetermined consensus criteria, which included special weighting of patients’ opinions in the first two voting rounds. The coreNASH Delphi panel included 53 participants (7 patients, 10 clinicians and researchers, 7 health technology assessors, 22 industry representatives, 2 regulators, and 5 payers) who considered outcomes for two NASH-related COS: one for NASH without cirrhosis (F2-F3) and one for NASH with cirrhosis (F4). The initial candidate outcome list for both disease stages included 86 outcomes. The panel agreed on including two core outcomes for NASH without cirrhosis and nine core outcomes for NASH with cirrhosis in the COS. Conclusion: A consensus-based COS has been developed that can be used across the life cycle of NASH treatments. Outcomes included can contribute to decision making for regulatory, market access, and on-market decision making. Including the coreNASH COS in clinical development programs will facilitate improved comparisons and help decision makers assess the value of new products

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    First Phase 1 Double-Blind, Placebo-Controlled, Randomized Rectal Microbicide Trial Using UC781 Gel with a Novel Index of Ex Vivo Efficacy

    Get PDF
    Objectives: Successful control of the HIV/AIDS pandemic requires reduction of HIV-1 transmission at sexually-exposed mucosae. No prevention studies of the higher-risk rectal compartment exist. We report the first-in-field Phase 1 trial of a rectally-applied, vaginally-formulated microbicide gel with the RT-inhibitor UC781 measuring clinical and mucosal safety, acceptability and plasma drug levels. A first-in-Phase 1 assessment of preliminary pharmacodynamics was included by measuring changes in ex vivo HIV-1 suppression in rectal biopsy tissue after exposure to product in vivo. Methods: HIV-1 seronegative, sexually-abstinent men and women (N = 36) were randomized in a double-blind, placebo-controlled trial comparing UC781 gel at two concentrations (0.1%, 0.25%) with placebo gel (1:1:1). Baseline, single-dose exposure and a separate, 7-day at-home dosing were assessed. Safety and acceptability were primary endpoints. Changes in colorectal mucosal markers and UC781 plasma drug levels were secondary endpoints; ex vivo biopsy infectibility was an ancillary endpoint. Results: All 36 subjects enrolled completed the 7-14 week trial (100% retention) including 3 flexible sigmoidoscopies, each with 28 biopsies (14 at 10 cm; 14 at 30 cm). There were 81 Grade 1 adverse events (AEs) and 8 Grade 2; no Grade 3, 4 or procedure-related AEs were reported. Acceptability was high, including likelihood of future use. No changes in mucosal immunoinflammatory markers were identified. Plasma levels of UC781 were not detected. Ex vivo infection of biopsies using two titers of HIV-1 BaL showed marked suppression of p24 in tissues exposed in vivo to 0.25% UC781; strong trends of suppression were seen with the lower 0.1% UC781 concentration. Conclusions: Single and 7-day topical rectal exposure to both concentrations of UC781 were safe with no significant AEs, high acceptability, no detected plasma drug levels and no significant mucosal changes. Ex vivo biopsy infections demonstrated marked suppression of HIV infectibility, identifying a potential early biomarker of efficacy. (Registered at ClinicalTrials.gov; #NCT00408538). Š 2011 Anton et al

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore