209 research outputs found
Reducing Sound Levels of Granulator at ORBIS Corporation
The plastic granulation process at OrbisCorporation produces noise levels up to 114 decibels. The current noise level at the closest operator station from the grinder is 90 dB.Due to OSHA regulations, noise levels must be decreased to at or below 85 decibels at the nearest operator station
Recommended from our members
Model-Based Signal Processing: Correlation Detection With Synthetic Seismograms
Recent applications of correlation methods to seismological problems illustrate the power of coherent signal processing applied to seismic waveforms. Examples of these applications include detection of low amplitude signals buried in ambient noise and cross-correlation of sets of waveforms to form event clusters and accurately measure delay times for event relocation and/or earth structure. These methods rely on the exploitation of the similarity of individual waveforms and have been successfully applied to large sets of empirical observations. However, in cases with little or no empirical event data, such as aseismic regions or exotic event types, correlation methods with observed seismograms will not be possible due to the lack of previously observed similar waveforms. This study uses model-based signals computed for three-dimensional (3D) Earth models to form the basis for correlation detection. Synthetic seismograms are computed for fully 3D models estimated from the Markov Chain Monte-Carlo (MCMC) method. MCMC uses stochastic sampling to fit multiple seismological data sets. Rather than estimate a single ''optimal'' model, MCMC results in a suite of models that sample the model space and incorporates uncertainty through variability of the models. The variability reflects our ignorance of Earth structure, due to limited resolution, data and modeling errors, and produces variability in the seismic waveform response. Model-based signals are combined using a subspace method where the synthetic signals are decomposed into an orthogonal basis by singular-value decomposition (SVD) and the observed waveforms are represented with a linear combination of a sub-set of eigenvectors (signals) associated with the most significant eigenvalues. We have demonstrated the method by modeling long-period (80-10 seconds) regional seismograms for a moderate (M{approx}5) earthquake near the China-North Korea border. Synthetic seismograms are computed with the Spectral Element Method for a suite of long-wavelength (2 degree) seismic velocity models based on the MCMC method. We are working on higher resolution (1 degree) models for the same region and methods to increase the frequency content of the synthetic seismograms
Exploring the spectral properties of faint hard X-ray sources with XMM-Newton
We present a spectroscopic study of 41 hard X-ray sources detected
serendipitously with high significance (> 5 sigma in the 2-10 keV band) in
seven EPIC performance/verification phase observations. The large collecting
area of EPIC allows us to explore the spectral properties of these faint hard
X-ray sources with 2< F_{2-10} < 80 x 10^{-14} erg cm^{-2}s^{-1} even though
the length of the exposures are modest (~ 20 ks). Optical identifications are
available for 21 sources of our sample. Using a simple power law plus Galactic
absorption model we find an average value of the photon index Gamma ~ 1.6-1.7,
broadly consistent with recent measurements made at similar fluxes with ASCA
and with Chandra stacked spectral analyses. We find that 31 out of 41 sources
are well fitted by this simple model and only eight sources require absorption
in excess of the Galactic value. Interestingly enough, one third of these
absorbed sources are broad line objects, though with moderate column densities.
Two sources in the sample are X-ray bright optically quiet galaxies and show
flat X-ray spectra. Comparing our observational results with those expected
from standard synthesis models of the cosmic X-ray background (CXB) we find a
fraction of unabsorbed to absorbed sources larger than predicted by theoretical
models at our completeness limit of F_{2-10} ~ 5 x 10^{-14} erg cm^{-2}s^{-1}.
The results presented here illustrate well how wide-angle surveys performed
with EPIC on board XMM-Newton allow population studies of interesting and
unusual sources to be made as well as enabling constraints to be placed on some
input parameters for synthesis models of the CXB.Comment: 16 pages, 11 figures. To be published in A&
Bisulfite-free analysis of 5MeC-binding proteins and locus-specific methylation density using a microparticle-based flow cytometry assay
DNA methylation analysis is emerging as a new technique with potential capabilities for early cancer detection. However, current state-of-the-art techniques are not easily translatable into routine clinical methods. Herein we describe a bead-based flow cytometry assay which combines DNA hybridization to microparticles with 5MeC-specific proteins/antibodies. These assays can be used to study the binding properties of current and emerging 5MeC-binding proteins and may also have potential in the measurement of 5MeC density in clinical samples for cancer detection
A deep Chandra observation of the Groth Strip. I. The X-ray data
We present the results of a 200 ks Chandra observation of part of the Groth
Strip region, using the ACIS-I instrument. We present a relatively simple
method for the detection of point-sources and calculation of limiting
sensitivities, which we argue is at least as sensitive and more self-consistent
than previous methods presented in the literature. 158 distinct X-ray sources
are included in our point-source catalogue in the ACIS-I area. The number
counts show a relative dearth of X-ray sources in this region. For example at a
flux limit of 1E-15 (cgs) around 20 per cent more soft band sources are
detected in the HDF-N and almost 50 per cent more in the ELAIS-N1 field, which
we have analysed by the same method for comparison. We find, however, that
these differences are consistent with Poisson variations at 2 sigma
significance, and therefore there is no evidence for cosmic variance based on
these number counts alone. We determine the average spectra of the objects and
find a marked difference between the soft-band selected sources, which have
Gamma=1.9 typical of unobscured AGN, and the hard-band selected sources, which
have Gamma=1.0. Reassuringly, the sample as a whole has a mean spectrum of
Gamma=1.4\pm 0.1, the same as the X-ray background. Nonetheless, our results
imply that the fraction of sources with significant obscuration is only ~25 per
cent, much less than predicted by standard AGN population synthesis models.
This is confirmed by direct spectral fitting, with only a handful of objects
showing evidence for absorption. After accounting for absorption, all objects
are consistent with mean intrinsic spectrum of Gamma=1.76 \pm 0.08, very
similar to local Seyferts (abridged).Comment: 17 pages, 4 figures, MNRAS, in pres
Dark sectors 2016 Workshop: community report
This report, based on the Dark Sectors workshop at SLAC in April 2016,
summarizes the scientific importance of searches for dark sector dark matter
and forces at masses beneath the weak-scale, the status of this broad
international field, the important milestones motivating future exploration,
and promising experimental opportunities to reach these milestones over the
next 5-10 years
Rats selectively bred for low aerobic capacity have reduced hepatic mitochondrial oxidative capacity and susceptibility to hepatic steatosis and injury
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65411/1/jphysiol.2009.169060.pd
HIV Risk Behavior Self-Report Reliability at Different Recall Periods
Few studies have investigated the optimal length of recall period for self-report of sex and drug-use behaviors. This meta-analysis of 28 studies examined the test-retest reliability of three commonly used recall periods: 1, 3, and 6 months. All three recall periods demonstrated acceptable test-retest reliability, with the exception of recall of needle sharing behaviors and 6-months recall of some sex behaviors. For most sex behaviors, a recall period of 3 months was found to produce the most reliable data; however, 6 months was best for recalling number of sex partners. Overall, shorter periods were found to be more reliable for recall of drug-use behaviors, though the most reliable length of recall period varied for different types of drugs. Implications of the findings and future directions for research are discussed
Introduction and validation of Psychopathic Personality Traits Scale (PPTS) in a large prison sample
Purpose: The aim of this study was to create and validate a brief self-report scale of psychopathic personality traits for research purposes which would grasp the essence of a psychopathic personality, regardless of respondents’ age, gender, cultural background, and criminal history. Methods: The Psychopathic Personality Traits Scale (PPTS), The Measure of Criminal Social Identity, Self-Esteem Measure for Criminals, The Child Sexual Abuse Myth Scale, Attitudes Towards Male Sexual Dating Violence, and Lie Scale were administered to 1,794 prisoners systematically sampled from 10 maximum- and medium-security prisons. Dimensionality and construct validity of the PPTS was investigated using traditional CFA techniques, along with confirmatory bifactor analysis and multitrait-multimethod modelling (MTMM). Seven alternative models of the PPTS were specified and tested using Mplus with WLSMV estimation. Results: MTMM model of PPTS offered the best representation of the data. The results suggest that the PPTS consists of four subscales (affective responsiveness, cognitive responsiveness, interpersonal manipulation, and egocentricity) while controlling for two method factors (knowledge/skills and attitudes/beliefs). Good composite reliability and differential predictive validity was observed. Conclusion: This brief measure of psychopathic traits uncontaminated with behavioural items can be used in the same way among participants with and without criminal history
- …