84 research outputs found

    Exploring Cosmic Origins with CORE: Cosmological Parameters

    Get PDF
    We forecast the main cosmological parameter constraints achievable with theCORE space mission which is dedicated to mapping the polarisation of the CosmicMicrowave Background (CMB). CORE was recently submitted in response to ESA'sfifth call for medium-sized mission proposals (M5). Here we report the resultsfrom our pre-submission study of the impact of various instrumental options, inparticular the telescope size and sensitivity level, and review the great,transformative potential of the mission as proposed. Specifically, we assessthe impact on a broad range of fundamental parameters of our Universe as afunction of the expected CMB characteristics, with other papers in the seriesfocusing on controlling astrophysical and instrumental residual systematics. Inthis paper, we assume that only a few central CORE frequency channels areusable for our purpose, all others being devoted to the cleaning ofastrophysical contaminants. On the theoretical side, we assume LCDM as ourgeneral framework and quantify the improvement provided by CORE over thecurrent constraints from the Planck 2015 release. We also study the jointsensitivity of CORE and of future Baryon Acoustic Oscillation and Large ScaleStructure experiments like DESI and Euclid. Specific constraints on the physicsof inflation are presented in another paper of the series. In addition to thesix parameters of the base LCDM, which describe the matter content of aspatially flat universe with adiabatic and scalar primordial fluctuations frominflation, we derive the precision achievable on parameters like thosedescribing curvature, neutrino physics, extra light relics, primordial heliumabundance, dark matter annihilation, recombination physics, variation offundamental constants, dark energy, modified gravity, reionization and cosmicbirefringence. (ABRIDGED

    Long-range angular correlations on the near and away side in p–Pb collisions at

    Get PDF

    Underlying Event measurements in pp collisions at s=0.9 \sqrt {s} = 0.9 and 7 TeV with the ALICE experiment at the LHC

    Full text link

    Double functionalization for the design of innovative craniofacial prostheses

    No full text
    International audienceTitanium (Ti) is the most commonly used material for cranial prostheses. However, this material does not exhibit the same mechanical properties as the bone. Incorporating polymers onto Ti by combining both their properties is a solution to overcome this issue. Thus, sandwich materials made of two Ti skin sheets and a poly(methyl methacrylate) (PMMA) core are promising structures to design biomedical prostheses. The "grafting to" and "grafting from" procedures to functionalize the Ti/PMMA interface are described in this paper as two strategies for chemically connecting PMMA chains on Ti surfaces. The advantage of the first approach is the capacity to control the architecture of the grafted PMMA on Ti. Moreover, a method for selectively grafting a bioactive polymer such as poly(sodium styrene sulfonate) (PNaSS) on one side of the Ti and PMMA on the other side is developed. This contribution presents efficient ways of functionalizing Ti for biomedical applications

    Where Brain, Body and World Collide

    Get PDF
    The production cross section of electrons from semileptonic decays of beauty hadrons was measured at mid-rapidity (|y| < 0.8) in the transverse momentum range 1 < pt < 8 Gev/c with the ALICE experiment at the CERN LHC in pp collisions at a center of mass energy sqrt{s} = 7 TeV using an integrated luminosity of 2.2 nb^{-1}. Electrons from beauty hadron decays were selected based on the displacement of the decay vertex from the collision vertex. A perturbative QCD calculation agrees with the measurement within uncertainties. The data were extrapolated to the full phase space to determine the total cross section for the production of beauty quark-antiquark pairs

    Final results from GCIG/ENGOT/AGO-OVAR 12, a randomised placebo-controlled phase III trial of nintedanib combined with chemotherapy for newly diagnosed advanced ovarian cancer

    No full text
    AGO-OVAR 12 investigated the effect of adding the oral triple angiokinase inhibitor nintedanib to standard front-line chemotherapy for advanced ovarian cancer. At the primary analysis, nintedanib demonstrated significantly improved progression-free survival (PFS; primary endpoint) compared with placebo. We report final results, including overall survival (OS). Patients with primary debulked International Federation of Gynaecology and Obstetrics (FIGO) stage IIB-IV newly diagnosed ovarian cancer were randomised 2:1 to receive carboplatin (area under the curve 5 or 6) plus paclitaxel (175 mg/m2 ) on day 1 every 3 weeks for six cycles combined with either nintedanib 200 mg or placebo twice daily on days 2-21 every 3 weeks for up to 120 weeks. Between December 2009 and July 2011, 1,366 patients were randomised (911 to nintedanib, 455 to placebo). Disease was considered as high risk (FIGO stage III with >1 cm residuum, or any stage IV) in 39%. At the final analysis, 605 patients (44%) had died. There was no difference in OS (hazard ratio 0.99, 95% confidence interval [CI] 0.83-1.17, p = 0.86; median 62.0 months with nintedanib vs. 62.8 months with placebo). Subgroup analyses according to stratification factors, clinical characteristics and risk status showed no OS difference between treatments. The previously reported PFS improvement seen with nintedanib did not translate into an OS benefit in the nonhigh-risk subgroup. Updated PFS results were consistent with the primary analysis (hazard ratio 0.86, 95% CI 0.75-0.98; p = 0.029) favouring nintedanib. The safety profile was consistent with previous reports.status: publishe

    CCM.G-K2 key comparison

    Get PDF
    International audienceIn November 2013 an International Key Comparison, CCM.G-K2, was organized in the Underground Laboratory for Geodynamics in Walferdange. The comparison has assembled 25 participants coming from 19 countries and four different continents. The comparison was divided into two parts: the key comparison that included 10 NMIs or DIs, and the pilot study including all participants. The global result given by the pilot study confirms that all instruments are absolutely coherent to each other. The results obtained for the key comparison confirm a good agreement between the NMI instruments
    corecore