332 research outputs found
Comparison of the performance of sensitivity-based voltage control algorithms in DG-integrated distribution systems
Conference ProceedingsThe integration of renewable energy generators in distribution grids has increased the
complexity of the voltage control problem. Reactive power control (RPC) algorithms based on
sensitivity analysis have been proposed in the literature for the management of the voltage problem.
Sensitivity methods are computationally complex for practical real-time analysis and this has led to
use of de-coupled and other simplified load flow models. However, algorithms based on decoupled
models have been shown to be inefficient for analysis of distribution systems with low X/R ratio. This
paper uses a simplified line modelling approach recently proposed in the literature to facilitate the
development of computationally simple distributed, non-decoupled, load flow equations that
completely capture the characteristics of the radial distribution feeder, removing the need to use the
decoupled models. Results show that the simple algorithm based on this new line modelling approach
gives better voltage control performance compared to the decoupled models
Optimal Control System of Under Frequency Load Shedding in Microgrid System with Renewable Energy Resources
Book ChapterNowadays many of the power systems are facing serious problems
because of the lack of know-how to utilize the available renewable energy resources
(RER) so as to balance between the power supply and demand sides. As the
consequence of the power unbalancing into their distribution networks, under frequency
load shedding (UFLS) which leads to life span reduction of various
expensive equipment and deteriorating production in general are of much concerns.
Thus, proper control system for the load flow in a system like microgrids (MG) with
RER in general is the first thing to carry out the assessment with the aim to solve the
power balancing problem within the power system networks. Actually, the major
problems which many utilities are facing all over the world are how to utilize the
available and future energy resource reserves in order to balance between the
supply and demand sides within their power distribution networks. Moreover,
because of the quick, improvised and unforeseen increasing number of consumers’
power demands and lack of additional macro energy resources plants which can
favorably respond to the instantaneous consumer requirements, optimal control
strategy (OCS) is inevitable. The OCS is required to maintain the steady-state
operations and ensure the reliability of the entire distribution system over a long
period. For that case, the OCS is required to principally stabilize parameters such as
voltage, frequency, and limit the injection of reactive power into the MG system
under stress. Therefore, in this chapter, the OCS is proposed as an approach to be applied in an intelligent way to solve the UFLS and blackout problems (BP) in a
typical MG with RER. The proposed control solution is analyzed using emergency
power supply reserves integrated with RER. These typical energy resources can be
wind and photovoltaic (solar PV) systems associated with the battery energy
storage system (BESS), hydro pump storage, biomass power plant and fuel cell
systems
Transient stability control by means of under-frequency load shedding and a hybrid control scheme
An electrical network constantly faces unforeseen events such as faults on lines, loss of load and loss of generation. Under-frequency load shedding and generator tripping are traditional methods used to stabilise a network when a transient fault occurs. These methods will prevent any network instability by shedding load or tripping the most critical generator at a calculated time when required. By executing these methods, the network can be stabilised in terms of balancing the generation and the load of a power system. A hybrid control scheme is proposed where the traditional methods are combined to reduce the stress levels exerted on the network and to minimise the load to be shed
Recloser based energy exposure assessment of a distribution network
The optimised placement of reclosers on a distribution network is known to improve the reliability of a power system. Furthermore, the protection settings on distribution systems rely heavily on the number and placement of such reclosers. This study examined the effect of using protection settings methodology with the placement of reclosers to ameliorate the damage sustained during faults on a distribution network. The aim of the study was to determine whether this ‘damage control factor’ should be a future consideration for recloser placement. It has been found that the determination of the number and placement of reclosers, which are the function of the energy exposure of feeder, helped to optimise the operation and reliability of a distribution network. This could benefit both energy users and energy suppliers, who often face different challenges during the fault levels on the network
Cationic agent contrast-enhanced computed tomography imaging of cartilage correlates with the compressive modulus and coefficient of friction
SummaryObjectiveThe aim of this study is to evaluate whether contrast-enhanced computed tomography (CECT) attenuation, using a cationic contrast agent (CA4+), correlates with the equilibrium compressive modulus (E) and coefficient of friction (μ) of ex vivo bovine articular cartilage.MethodsCorrelations between CECT attenuation and E (Group 1, n = 12) and μ (Group 2, n = 10) were determined using 7 mm diameter bovine osteochondral plugs from the stifle joints of six freshly slaughtered, skeletally mature cows. The equilibrium compressive modulus was measured using a four-step, unconfined, compressive stress-relaxation test, and the coefficients of friction were determined from a torsional friction test. Following mechanical testing, samples were immersed in CA4+, imaged using μCT, rinsed, and analyzed for glycosaminoglycan (GAG) content using the 1,9-dimethylmethylene blue (DMMB) assay.ResultsThe CECT attenuation was positively correlated with the GAG content of bovine cartilage (R2 = 0.87, P < 0.0001 for Group 1 and R2 = 0.74, P = 0.001 for Group 2). Strong and significant positive correlations were observed between E and GAG content (R2 = 0.90, P < 0.0001) as well as CECT attenuation and E (R2 = 0.90, P < 0.0001). The CECT attenuation was negatively correlated with the three coefficients of friction: CECT vs μstatic (R2 = 0.71, P = 0.002), CECT vs μstatic_equilibrium (R2 = 0.79, P < 0.001), and CECT vs μkinetic (R2 = 0.69, P = 0.003).ConclusionsCECT with CA4+ is a useful tool for determining the mechanical properties of ex vivo cartilage tissue as the attenuation significantly correlates with the compressive modulus and coefficient of friction
Balanços energéticos agropecuários: uma importante ferramenta como indicativo de sustentabilidade de agroecossistemas.
No Brasil, pouca atenção se tem dado às formas e caminhos com que os fluxos energéticos se distribuem nos sistemas produtivos. Na agropecuária, a atenção tem sido voltada a novas fontes de energia (biomassa) ou em tecnologia alternativa, visando a racionalização do uso de energia fóssil ou elétrica. Entretanto, a agricultura tem se desenvolvido baseada fortemente na utilização intensiva de máquinas agrícolas, com conseqüente uso de combustíveis fósseis. Um fator de estrangulamento muito forte no consumo energético geral tem sido a utilização massiva de fertilizantes derivados do petróleo nos agroecossistemas. Estudos de Balanços Energéticos visam determinar os pontos de estrangulamento energético fundamentando a busca por tecnologias poupadoras de energia, especialmente aquelas de origem fóssil (combustível, fertilizante, agrotóxicos, energia despendida na fabricação das máquinas e implementos, etc.). No Brasil, a Região Sul, é onde se encontram vários trabalhos buscando uma agricultura mais auto-sustentável, do ponto de vista da utilização da energia. Em vista da possibilidade de eventuais futuras crises energéticas, o presente trabalho procura analisar o estado-da-arte dos estudos em Balanço Energético, no Brasil e no Mundo, como uma ferramenta de indicação da sustentabilidade dos sistemas agropecuários
Measurement of the polarisation of W bosons produced with large transverse momentum in pp collisions at sqrt(s) = 7 TeV with the ATLAS experiment
This paper describes an analysis of the angular distribution of W->enu and
W->munu decays, using data from pp collisions at sqrt(s) = 7 TeV recorded with
the ATLAS detector at the LHC in 2010, corresponding to an integrated
luminosity of about 35 pb^-1. Using the decay lepton transverse momentum and
the missing transverse energy, the W decay angular distribution projected onto
the transverse plane is obtained and analysed in terms of helicity fractions
f0, fL and fR over two ranges of W transverse momentum (ptw): 35 < ptw < 50 GeV
and ptw > 50 GeV. Good agreement is found with theoretical predictions. For ptw
> 50 GeV, the values of f0 and fL-fR, averaged over charge and lepton flavour,
are measured to be : f0 = 0.127 +/- 0.030 +/- 0.108 and fL-fR = 0.252 +/- 0.017
+/- 0.030, where the first uncertainties are statistical, and the second
include all systematic effects.Comment: 19 pages plus author list (34 pages total), 9 figures, 11 tables,
revised author list, matches European Journal of Physics C versio
Observation of a new chi_b state in radiative transitions to Upsilon(1S) and Upsilon(2S) at ATLAS
The chi_b(nP) quarkonium states are produced in proton-proton collisions at
the Large Hadron Collider (LHC) at sqrt(s) = 7 TeV and recorded by the ATLAS
detector. Using a data sample corresponding to an integrated luminosity of 4.4
fb^-1, these states are reconstructed through their radiative decays to
Upsilon(1S,2S) with Upsilon->mu+mu-. In addition to the mass peaks
corresponding to the decay modes chi_b(1P,2P)->Upsilon(1S)gamma, a new
structure centered at a mass of 10.530+/-0.005 (stat.)+/-0.009 (syst.) GeV is
also observed, in both the Upsilon(1S)gamma and Upsilon(2S)gamma decay modes.
This is interpreted as the chi_b(3P) system.Comment: 5 pages plus author list (18 pages total), 2 figures, 1 table,
corrected author list, matches final version in Physical Review Letter
- …