44 research outputs found

    Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

    Get PDF
    The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysic

    The European Photon Imaging Camera on XMM-Newton: The MOS Cameras

    Get PDF
    The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record the images and spectra of celestial X-ray sources focused by the three X-ray mirrors. There is one camera at the focus of each mirror; two of the cameras contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a circular field of view of 30 arcmin diameter in each case. The CCDs were specially developed for EPIC, and combine high quality imaging with spectral resolution close to the Fano limit. A filter wheel carrying three kinds of X-ray transparent light blocking filter, a fully closed, and a fully open position, is fitted to each EPIC instrument. The CCDs are cooled passively and are under full closed loop thermal control. A radio-active source is fitted for internal calibration. Data are processed on-board to save telemetry by removing cosmic ray tracks, and generating X-ray event files; a variety of different instrument modes are available to increase the dynamic range of the instrument and to enable fast timing. The instruments were calibrated using laboratory X-ray beams, and synchrotron generated monochromatic X-ray beams before launch; in-orbit calibration makes use of a variety of celestial X-ray targets. The current calibration is better than 10% over the entire energy range of 0.2 to 10 keV. All three instruments survived launch and are performing nominally in orbit. In particular full field-of-view coverage is available, all electronic modes work, and the energy resolution is close to pre-launch values. Radiation damage is well within pre-launch predictions and does not yet impact on the energy resolution. The scientific results from EPIC amply fulfil pre-launch expectations.Comment: 9 pages, 11 figures, accepted for publication in the A&A Special Issue on XMM-Newto

    Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

    Get PDF
    We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f1/f stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.Comment: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010

    The AGILE Mission

    Get PDF
    AGILE is an Italian Space Agency mission dedicated to observing the gamma-ray Universe. The AGILE's very innovative instrumentation for the first time combines a gamma-ray imager (sensitive in the energy range 30 MeV-50 GeV), a hard X-ray imager (sensitive in the range 18-60 keV), a calorimeter (sensitive in the range 350 keV-100 MeV), and an anticoincidence system. AGILE was successfully launched on 2007 April 23 from the Indian base of Sriharikota and was inserted in an equatorial orbit with very low particle background. Aims. AGILE provides crucial data for the study of active galactic nuclei, gamma-ray bursts, pulsars, unidentified gamma-ray sources, galactic compact objects, supernova remnants, TeV sources, and fundamental physics by microsecond timing. Methods. An optimal sky angular positioning (reaching 0.1 degrees in gamma- rays and 1-2 arcmin in hard X-rays) and very large fields of view (2.5 sr and 1 sr, respectively) are obtained by the use of Silicon detectors integrated in a very compact instrument. Results. AGILE surveyed the gamma- ray sky and detected many Galactic and extragalactic sources during the first months of observations. Particular emphasis is given to multifrequency observation programs of extragalactic and galactic objects. Conclusions. AGILE is a successful high-energy gamma-ray mission that reached its nominal scientific performance. The AGILE Cycle-1 pointing program started on 2007 December 1, and is open to the international community through a Guest Observer Program

    Planck pre-launch status : The Planck mission

    Get PDF
    Peer reviewe

    Epidemiology of intra-abdominal infection and sepsis in critically ill patients: “AbSeS”, a multinational observational cohort study and ESICM Trials Group Project

    Get PDF
    Purpose: To describe the epidemiology of intra-abdominal infection in an international cohort of ICU patients according to a new system that classifies cases according to setting of infection acquisition (community-acquired, early onset hospital-acquired, and late-onset hospital-acquired), anatomical disruption (absent or present with localized or diffuse peritonitis), and severity of disease expression (infection, sepsis, and septic shock). Methods: We performed a multicenter (n = 309), observational, epidemiological study including adult ICU patients diagnosed with intra-abdominal infection. Risk factors for mortality were assessed by logistic regression analysis. Results: The cohort included 2621 patients. Setting of infection acquisition was community-acquired in 31.6%, early onset hospital-acquired in 25%, and late-onset hospital-acquired in 43.4% of patients. Overall prevalence of antimicrobial resistance was 26.3% and difficult-to-treat resistant Gram-negative bacteria 4.3%, with great variation according to geographic region. No difference in prevalence of antimicrobial resistance was observed according to setting of infection acquisition. Overall mortality was 29.1%. Independent risk factors for mortality included late-onset hospital-acquired infection, diffuse peritonitis, sepsis, septic shock, older age, malnutrition, liver failure, congestive heart failure, antimicrobial resistance (either methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, extended-spectrum beta-lactamase-producing Gram-negative bacteria, or carbapenem-resistant Gram-negative bacteria) and source control failure evidenced by either the need for surgical revision or persistent inflammation. Conclusion: This multinational, heterogeneous cohort of ICU patients with intra-abdominal infection revealed that setting of infection acquisition, anatomical disruption, and severity of disease expression are disease-specific phenotypic characteristics associated with outcome, irrespective of the type of infection. Antimicrobial resistance is equally common in community-acquired as in hospital-acquired infection

    Carbohydrate-mediated sperm-egg interaction and species specificity: a clue from the Unio elongatulus model.

    No full text
    As a first step fertilization requires that sperm bind to the extracellular coat of the egg. It is generally accepted that binding is mediated by complex carbohydrates on the egg coat, recognized by carbohydrate-binding proteins on the sperm surface. In the mollusc bivalve Unio elongatulus, the main functional epitope of the carbohydrate ligand has been determined, and it shares several characteristics with other sugar structures involved in the fertilization process in different animal models. A polyclonal antibody against the Unio epitope reacts with the human ZP3 glycoprotein and the Unio ligand binds human spermatozoa in an in vitro assay. These findings are discussed in the light of the species specificity of sperm-egg binding at fertilization

    Sperm treatment with extracellular ATP increases fertilization rates in in-vitro fertilization for male factor infertility.

    No full text
    Previous work from our laboratory has revealed that extracellular ATP is a rapid and potent activator of human sperm acrosome reaction and fertilizing ability. In the present study, we assessed the effects of in-vitro sperm incubation with ATP on fertilization and embryo development in couples undergoing in-vitro fertilization (IVF) for male factor infertility. Oocytes from 22 women undergoing ovulation induction were divided in two groups and inseminated in vitro either with selected spermatozoa from the corresponding partner suffering from male factor infertility pre-incubated with ATP (2.5 mM) for 1 h, or with spermatozoa incubated with 0.9% NaCl solution (control group). After insemination, fertilization was assessed by the presence of pronuclei and then by embryo cleavage. The fertilization rate in the group of oocytes inseminated with ATP-treated spermatozoa improved significantly with respect to the control group (65.7 versus 42.5%, P < 0.01). No significant differences were observed in embryo cleavage and embryo quality. Embryos from both treated and control groups were transferred together in 20 transfer procedures, and in two couples fertilization was not obtained. Nine pregnancies occurred: one biochemical, one miscarriage, and seven patients delivered 9 healthy babies. Two pregnancies were twin with an overall pregnancy rate of 40.9% per cycle and of 45% per transfer. In conclusion, the results of the present study demonstrate that, in humans, extracellular ATP induces a significant increase of sperm fertilizing potential, as these findings are a rationale for the use of ATP for in-vitro treatment of human spermatozoa during IVF

    Sperm treatment with extracellular ATP increases fertilization rates in in-vitro fertilization for male factor infertility

    No full text
    Previous work from our laboratory has revealed that extracellular ATP is a rapid and potent activator of human sperm acrosome reaction and fertilizing ability. In the present study, we assessed the effects of in-vitro sperm incubation with ATP on fertilization and embryo development in couples undergoing in-vitro fertilization (IVF) for male factor infertility. Oocytes from 22 women undergoing ovulation induction were divided in two groups and inseminated in vitro either with selected spermatozoa from the corresponding partner suffering from male factor infertility pre-incubated with ATP (2.5 mM) for 1 h, or with spermatozoa incubated with 0.9% NaCl solution (control group). After insemination, fertilization was assessed by the presence of pronuclei and then by embryo cleavage. The fertilization rate in the group of oocytes inseminated with ATP-treated spermatozoa improved significantly with respect to the control group (65.7 versus 42.5%, P < 0.01). No significant differences were observed in embryo cleavage and embryo quality. Embryos from both treated and control groups were transferred together in 20 transfer procedures, and in two couples fertilization was not obtained. Nine pregnancies occurred: one biochemical, one miscarriage, and seven patients delivered 9 healthy babies. Two pregnancies were twin with an overall pregnancy rate of 40.9% per cycle and of 45% per transfer. In conclusion, the results of the present study demonstrate that, in humans, extracellular ATP induces a significant increase of sperm fertilizing potential, as these findings are a rationale for the use of ATP for in-vitro treatment of human spermatozoa during IVF

    Follicular fluid as a favourable environment for endometrial and endometriotic cell growth in vitro.

    No full text
    Follicular fluid from women with endometriosis has been shown to induce a higher endometrial cell proliferation than that derived from women without the disease. To elucidate this issue further, the aims of the present study were to compare the ability of follicular fluid and peritoneal fluid to stimulate both endometrial and endometriotic cell proliferation and to verify whether the mitogenic effect was merely sex steroid-dependent. Endometrial and endometriotic cells were cultured in follicular fluid or peritoneal fluid diluted in serum-free media; the growth induced in these conditions was compared with that obtained by culturing these cells in medium supplemented with charcoal stripped calf serum and a correspondent content of 17-beta-oestradiol and progesterone. Follicular fluid was able to induce significantly higher cell proliferation than peritoneal fluid from controls, patients with endometriosis stage I-II and women with endometriosis stage III-IV (P < 0.05). Moreover, the growth in control media containing a corresponding amount of steroid hormones was significantly lower than that obtained with follicular or peritoneal fluids. This finding indicates that the stimulating effect is not simply related to the concentrations of 17-beta-oestradiol and progesterone present in these fluids. Finally, based on these results and on other previous observations, the hypothesis that follicular fluid may be involved in the development of endometriotic ovarian cysts is discussed
    corecore