The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record
the images and spectra of celestial X-ray sources focused by the three X-ray
mirrors. There is one camera at the focus of each mirror; two of the cameras
contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a
circular field of view of 30 arcmin diameter in each case. The CCDs were
specially developed for EPIC, and combine high quality imaging with spectral
resolution close to the Fano limit. A filter wheel carrying three kinds of
X-ray transparent light blocking filter, a fully closed, and a fully open
position, is fitted to each EPIC instrument. The CCDs are cooled passively and
are under full closed loop thermal control. A radio-active source is fitted for
internal calibration. Data are processed on-board to save telemetry by removing
cosmic ray tracks, and generating X-ray event files; a variety of different
instrument modes are available to increase the dynamic range of the instrument
and to enable fast timing. The instruments were calibrated using laboratory
X-ray beams, and synchrotron generated monochromatic X-ray beams before launch;
in-orbit calibration makes use of a variety of celestial X-ray targets. The
current calibration is better than 10% over the entire energy range of 0.2 to
10 keV. All three instruments survived launch and are performing nominally in
orbit. In particular full field-of-view coverage is available, all electronic
modes work, and the energy resolution is close to pre-launch values. Radiation
damage is well within pre-launch predictions and does not yet impact on the
energy resolution. The scientific results from EPIC amply fulfil pre-launch
expectations.Comment: 9 pages, 11 figures, accepted for publication in the A&A Special
Issue on XMM-Newto