11 research outputs found

    Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model

    Get PDF
    Bajgrowicz, M., Phan, C.-M., Subbaraman, L. N., & Jones, L. (2015). Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model. Investigative Opthalmology & Visual Science, 56(4), 2234. https://doi.org/10.1167/iovs.15-16379Purpose.: To analyze the release of two fluoroquinolones, ciprofloxacin and moxifloxacin, from conventional hydrogel (CH) and silicone hydrogel (SH) daily disposable contact lenses (CLs), comparing release from a fixed-volume vial and a novel in vitro eye model. Methods.: Four CH CLs (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three SH CLs (somofilcon A, narafilcon A, delefilcon A) were used. The lenses were incubated in drug solutions for 24 hours. After the incubation period, the lenses were placed in two release conditions: (1) a vial containing 4.8 mL PBS for 24 hours and (2) an in vitro eye model with a flow rate at 4.8 mL over 24 hours. Results.: Release in the vial for both drugs was rapid, reaching a plateau between 15 minutes and 2 hours for all lenses. In contrast, under physiological flow conditions, a constant and slow release was observed over 24 hours. The amounts of ciprofloxacin released from the lenses ranged between 49.6 ± 0.7 and 62.8 ± 0.3 μg per lens in the vial, and between 35.0 ± 7.0 and 109.0 ± 5.0 μg per lens in the eye model. Moxifloxacin release ranged from 24.0 ± 4.0 to 226.0 ± 2.0 μg per lens for the vial, and between 13.0 ± 2.0 and 151.0 ± 10.0 μg per lens in the eye model. In both systems and for both drugs, HEMA-based CLs released more drugs than other materials. Conclusions.: The parameters of the release system, in particular the volume and flow rate, have a significant influence on measured release profiles. Under physiological flow, release profiles are significantly slower and constant when compared with release in a vial

    Release of Moxifloxacin from Contact Lenses Using an In Vitro Eye Model: Impact of Artificial Tear Fluid Composition and Mechanical Rubbing

    Get PDF
    Phan, C.-M., Bajgrowicz-Cieslak, M., Subbaraman, L. N., & Jones, L. (2016). Release of Moxifloxacin from Contact Lenses Using an In Vitro Eye Model: Impact of Artificial Tear Fluid Composition and Mechanical Rubbing. Translational Vision Science & Technology, 5(6), 3. https://doi.org/10.1167/tvst.5.6.3Purpose: The aim of this study was to evaluate and compare the release of moxifloxacin from a variety of daily disposable (DD) contact lenses (CLs) under various conditions using a novel in vitro eye model. Methods: Four commercially available DD conventional hydrogel (CH) CLs (nelfilcon A, omafilcon A, etafilcon A, and ocufilcon B) and three silicone hydrogel (SH) CLs (somofilcon A, narafilcon A, and delefilcon A) were evaluated. These lenses were incubated in moxifloxacin for 24 hours. The release of the drug was measured using a novel in vitro model in three experimental conditions: (1) phosphate buffered saline (PBS); (2) artificial tear solution (ATS) containing a variety of proteins and lipids; and (3) ATS with mechanical rubbing produced by the device. Results: Overall, CH CLs had a higher drug release than SH CLs (P < 0.05) under all conditions. Typically, a higher drug release was observed in PBS than ATS (P < 0.05). For CH, drug release was found to be higher in ATS with rubbing than PBS or ATS (P < 0.05). For most lens types, ATS with rubbing produced higher drug release than ATS alone (P < 0.05). Generally, the release kinetics for all conditions were sustained over the 24-hour testing period, and no burst release was observed (P < 0.05). Conclusions: Moxifloxacin release from a CL into ATS is lower when compared to release into PBS. When mechanical rubbing is introduced, the amount of drugs released is increased. Translational Relevance: Results suggest that sophisticated in vitro models are necessary to adequately model on-eye drug release from CL materials

    Optical glucose sensors based on hexagonally-packed 2.5-dimensional photonic concavities imprinted in phenylboronic acid functionalized hydrogel films

    Get PDF
    Continuous glucose monitoring aims to achieve accurate control of blood glucose concentration to prevent hypo/hyperglycaemia in diabetic patients. Hydrogel-based systems have emerged as a reusable sensing platform to quantify biomarkers in high-risk patients at clinical and point-of-care settings. The capability to integrate hydrogel-based systems with optical transducers will provide quantitative and colorimetric measurements via spectrophotometric analyses of biomarkers. Here, we created an imprinting method to rapidly produce 2.5D photonic concavities in phenylboronic acid functionalized hydrogel films. Our method exploited diffraction properties of hexagonally-packed 2.5D photonic microscale concavities having a lattice spacing of 3.3 μm. Illumination of the 2.5D hexagonally-packed structure with a monochromatic light source in transmission mode allowed reversible and quantitative measurements of variation in the glucose concentration based on first order lattice interspace tracking. Reversible covalent phenylboronic acid coupling with cis-diols of glucose molecules expanded the hydrogel matrix by ∼2% and 34% in the presence of glucose concentrations of 1 mM and 200 mM, respectively. A Donnan osmotic pressure induced volumetric expansion of the hydrogel matrix due to increasing glucose concentrations (1–200 mM), resulted in a nanoscale modulation of the lattice interspace, and shifted the diffraction angle (∼45° to 36°) as well as the interspacing between the 1st order diffraction spots (∼8 to 3 mm). The sensor exhibited a maximum lattice spacing diffraction shift within a response time of 15 min in a reversible manner. The developed 2.5D photonic sensors may have application in medical point-of-care diagnostics, implantable chips, and wearable continuous glucose monitoring devices

    Wearables in medicine

    Get PDF
    Wearables as medical technologies are becoming an integral part of personal analytics, measuring physical status, recording physiological parameters, or informing schedule for medication. These continuously evolving technology platforms do not only promise to help people pursue a healthier life style, but also provide continuous medical data for actively tracking metabolic status, diagnosis, and treatment. Advances in the miniaturization of flexible electronics, electrochemical biosensors, microfluidics, and artificial intelligence algorithms have led to wearable devices that can generate real-time medical data within the Internet of things. These flexible devices can be configured to make conformal contact with epidermal, ocular, intracochlear, and dental interfaces to collect biochemical or electrophysiological signals. This article discusses consumer trends in wearable electronics, commercial and emerging devices, and fabrication methods. It also reviews real-time monitoring of vital signs using biosensors, stimuli-responsive materials for drug delivery, and closed-loop theranostic systems. It covers future challenges in augmented, virtual, and mixed reality, communication modes, energy management, displays, conformity, and data safety. The development of patient-oriented wearable technologies and their incorporation in randomized clinical trials will facilitate the design of safe and effective approaches

    In vitro release of two anti-muscarinic drugs from soft contact lenses

    No full text
    Alex Hui,1 Magdalena Bajgrowicz-Cieslak,2 Chau-Minh Phan,3 Lyndon Jones3 1School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia; 2Department of Mechanics, Material Science and Engineering, Wroclaw University of Technology, Wroclaw, Poland; 3Centre for Contact Lens Research, School of Optometry &amp; Vision Science, University of Waterloo, Waterloo, ON, Canada Abstract: The purpose of this study was to investigate the release of the anti-myopia drugs atropine sulfate and pirenzepine dihydrochloride from commercially available soft contact lenses. Standard ultraviolet (UV) absorbance&ndash;concentration curves were generated for atropine and pirenzepine. Ten commercially available contact lenses, including four multifocal lenses, were loaded by soaking in atropine or pirenzepine solutions at two different concentrations (10&nbsp;mg/mL and 1&nbsp;mg/mL). The release of the drugs into phosphate-buffered saline was determined over the course of 24&nbsp;hours at 34&deg;C using UV absorbance. Materials with surface charge released the greatest amount of atropine when loaded with either concentration when compared to the other lens types (p&lt;0.05), releasing upward of 1.026&plusmn;0.035&nbsp;mg/lens and 0.979&plusmn;0.024&nbsp;mg/lens from etafilcon A and ocufilcon A, respectively. There were no significant differences in the amount of atropine or pirenzepine released from the multifocal and non-multifocal lenses made from the same lens materials. Narafilcon A material demonstrated prolonged release of up to 8&nbsp;hours when loaded with pirenzepine, although the overall dose delivered from the lens into the solution was among the lowest of the materials investigated. The rest of the lenses reached a plateau within 2&nbsp;hours of release, suggesting that they were unable to sustain drug release into the solution for long periods of time. Given that no single method of myopia control has yet shown itself to be completely effective in preventing myopia progression, a combination of optical and pharmaceutical devices comprising a drug delivering contact lens presents a novel solution that warrants further investigation. Keywords: contact lens, drug delivery, myopia control, atropine, pirenzepine, multifocal&nbsp

    In vitro release of two anti-muscarinic drugs from soft contact lenses

    No full text
    © 2017 Hui et al. The purpose of this study was to investigate the release of the anti-myopia drugs atropine sulfate and pirenzepine dihydrochloride from commercially available soft contact lenses. Standard ultraviolet (UV) absorbance-concentration curves were generated for atropine and pirenzepine. Ten commercially available contact lenses, including four multifocal lenses, were loaded by soaking in atropine or pirenzepine solutions at two different concentrations (10 mg/mL and 1 mg/mL). The release of the drugs into phosphate-buffered saline was determined over the course of 24hours at 34°C using UV absorbance. Materials with surface charge released the greatest amount of atropine when loaded with either concentration when compared to the other lens types (p<0.05), releasing upward of 1.026±0.035mg/lens and 0.979±0.024mg/lens from etafilcon A and ocufilcon A, respectively. There were no significant differences in the amount of atropine or pirenzepine released from the multifocal and non-multifocal lenses made from the same lens materials. Narafilcon A material demonstrated prolonged release of up to 8 hours when loaded with pirenzepine, although the overall dose delivered from the lens into the solution was among the lowest of the materials investigated. The rest of the lenses reached a plateau within 2 hours of release, suggesting that they were unable to sustain drug release into the solution for long periods of time. Given that no single method of myopia control has yet shown itself to be completely effective in preventing myopia progression, a combination of optical and pharmaceutical devices comprising a drug delivering contact lens presents a novel solution that warrants further investigation

    Direct printing of nanostructured holograms on consumable substrates

    No full text
    Direct texturing of nanostructures on consumable substrates and products is a challenge because of incompatible ingredients and materials’ properties. Here, we developed a direct laser-based method to print nanostructured holograms on dried films of consumable corn syrup solutions. A holographic laser (λ = 1050 nm) interference system was used to construct the nanostructures of the holograms on food for rainbow effects. The relationship between wavelength and periodicity contributed to the changing diffraction angle through the change of the refractive index (1.642). Increasing the sugar concentration (25–175 mg) in the syrup increased the diffraction efficiency of these holograms. The added amount of sugar in the composition increased the refractive index (7%) and decreased the light absorption (12.9%), which influenced the change of diffraction angle by 4.4°. The surface holograms displayed wideband visual diffraction of light extending from violet to red wavelengths. These holograms on edible materials can be imprinted onto commercial food products for adding aesthetic value and controlling perception
    corecore