122 research outputs found

    Ectopia cordis: prenatal diagnosis, perinatal outcomes, and postnatal follow-up of an international multicenter cohort case series

    Get PDF
    Objective: This study aimed to analyze prenatal diagnosis, perinatal outcomes, and postnatal follow-up in fetuses with ectopia cordis (EC). Methods: This retrospective analysis accessed 31 patients with EC who were either diagnosed or referred to a tertiary Fetal Medicine centers for EC diagnosis in Brazil, Germany, Italy, and Poland. We analyzed prenatal diagnosis, perinatal outcomes, and follow-up in these patients. Results: Our study included a cohort of 31 fetuses with EC, 4 and 27 of whom had partial and complete protrusion of the heart through a ventral defect in the thoracoabdominal wall, respectively. EC was diagnosed by fetal echocardiography at a mean gestational age of 20.3 Â± 8.6 weeks (range, 8-35 weeks). Of the four cases, in which the karyotype was performed, all of them had a normal result (1 - 46,XX and 3 - 46,XY). Five patients showed conotruncal abnormalities and six ventricular septal defects. Termination of pregnancy (TOP) was performed in 15 cases (48%) and seven pregnant women had spontaneous fetal demise (22.5%). Of the seven fetuses that were born alive, four of them died, and three infants underwent surgery. Among these three infants, all of them survived, one was 5 months, 13 years old and 29 years old at the time of study completion. Conclusions: Ectopia cordis is associated with high mortality rates and intracardiac/extra-cardiac defects. Ventricular septal defects and conotruncal anomalies were the more common intracardiac defects associated with EC. However, in this cohort of fetuses with EC the incidence of PC was lower than reported in the literature

    Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy

    Get PDF
    Background. The purpose of the study was to evaluate inter- and intra-observer variability in sonographic measurements of the cross-sectional area of the umbilical cord and the diameters of its vessels in low-risk pregnancies of 12 to 40 weeks of gestation. Methods. A prospective cross sectional study was performed in 221 pregnant women at different gestational ages. Measurements were carried out also by a second observer to evaluate inter-observer variability and repeated once again by the first observer to assess intra-observer variability. The linear correlation between the measurements (Spearman's coefficient of correlation) and their reliability through the intraclass correlation coefficient (ICC), the Cronbach's alpha coefficient and the limits of agreement proposed by Bland and Altman were evaluated. Results. The results showed that inter-observer and intra-observer variability did not show any significant difference between examiners. A good linear correlation between the measurements and reliability was obtained, with values of R, ICC and Cronbach's alpha all above the standard limits. Conclusion. It is possible to conclude that inter- and intra-observer variability in the measurements of the umbilical cord and its vessels was small; their reliability and agreement were good. © 2008 Barbieri et al; licensee BioMed Central Ltd

    Urine tests for Down's syndrome screening

    Get PDF
    Background Down's syndrome occurs when a person has three copies of chromosome 21, or the specific area of chromosome 21 implicated in causing Down's syndrome, rather than two. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life. The risk of a Down's syndrome affected pregnancy increases with advancing maternal age. Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. Objectives To estimate and compare the accuracy of first and second trimester urine markers for the detection of Down's syndrome. Search methods We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), EMBASE (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2011, Issue 7), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (archived 2007), Health Services Research Projects in Progress database (25 August 2011). We studied reference lists and published review articles. Selection criteria Studies evaluating tests of maternal urine in women up to 24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. Data collection and analysis We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC (receiver operating characteristic) meta-analytical methods to analyse test performance and compare test accuracy. We performed analysis of studies allowing direct comparison between tests. We investigated the impact of maternal age on test performance in subgroup analyses. Main results We included 19 studies involving 18,013 pregnancies (including 527 with Down's syndrome). Studies were generally of high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Twenty-four test combinations were evaluated formed from combinations of the following seven different markers with and without maternal age: AFP (alpha-fetoprotein), ITA (invasive trophoblast antigen), ß-core fragment, free ßhCG (beta human chorionic gonadotrophin), total hCG, oestriol, gonadotropin peptide and various marker ratios. The strategies evaluated included three double tests and seven single tests in combination with maternal age, and one triple test, two double tests and 11 single tests without maternal age. Twelve of the 19 studies only evaluated the performance of a single test strategy while the remaining seven evaluated at least two test strategies. Two marker combinations were evaluated in more than four studies; second trimester ß-core fragment (six studies), and second trimester ß-core fragment with maternal age (five studies). In direct test comparisons, for a 5% false positive rate (FPR), the diagnostic accuracy of the double marker second trimester ß-core fragment and oestriol with maternal age test combination was significantly better (ratio of diagnostic odds ratio (RDOR): 2.2 (95% confidence interval (CI) 1.1 to 4.5), P = 0.02) (summary sensitivity of 73% (CI 57 to 85) at a cut-point of 5% FPR) than that of the single marker test strategy of second trimester ß-core fragment and maternal age (summary sensitivity of 56% (CI 45 to 66) at a cut-point of 5% FPR), but was not significantly better (RDOR: 1.5 (0.8 to 2.8), P = 0.21) than that of the second trimester ß-core fragment to oestriol ratio and maternal age test strategy (summary sensitivity of 71% (CI 51 to 86) at a cut-point of 5% FPR). Authors' conclusions Tests involving second trimester ß-core fragment and oestriol with maternal age are significantly more sensitive than the single marker second trimester ß-core fragment and maternal age, however, there were few studies. There is a paucity of evidence available to support the use of urine testing for Down's syndrome screening in clinical practice where alternatives are available

    Hypoplastic Left Heart Syndrome and Ventriculocoronary Connections

    No full text

    Body Stalk Anomaly in a 9-Week Pregnancy

    Get PDF
    Body stalk anomaly is a rare and severe malformation syndrome in which the exact pathophysiology and trigger factors are still unknown. This is a case of a 30-year-old patient who underwent ultrasound at 9 weeks of gestation. It revealed an abnormal location of the inferior body of the embryo in the coelomic space. The findings suggested a short umbilical cord syndrome. In order to confirm the diagnosis, the patient was scheduled for a second ultrasonography at 11 weeks of gestation. The obtained images, confirmed the location of the inferior body in the coelomic space with no visible bladder, absence of the right leg, severe abdominal wall defect, consistent with an omphalocele, and a short 5 mm umbilical cord. These last ultrasonographic findings were consistent with body stalk anomaly. Because of severe malformation incompatible with life, the patient was offered termination of pregnancy. Pathologic examination confirmed the suspected pathology of body stalk anomaly
    • 

    corecore