5,673 research outputs found

    A hierarchical system for a distributed representation of the peripersonal space of a humanoid robot

    Get PDF
    Reaching a target object in an unknown and unstructured environment is easily performed by human beings. However, designing a humanoid robot that executes the same task requires the implementation of complex abilities, such as identifying the target in the visual field, estimating its spatial location, and precisely driving the motors of the arm to reach it. While research usually tackles the development of such abilities singularly, in this work we integrate a number of computational models into a unified framework, and demonstrate in a humanoid torso the feasibility of an integrated working representation of its peripersonal space. To achieve this goal, we propose a cognitive architecture that connects several models inspired by neural circuits of the visual, frontal and posterior parietal cortices of the brain. The outcome of the integration process is a system that allows the robot to create its internal model and its representation of the surrounding space by interacting with the environment directly, through a mutual adaptation of perception and action. The robot is eventually capable of executing a set of tasks, such as recognizing, gazing and reaching target objects, which can work separately or cooperate for supporting more structured and effective behaviors

    Comparative Effectiveness of Biosimilar, Reference Product and Other Erythropoiesis-Stimulating Agents (ESAs) Still Covered by Patent in Chronic Kidney Disease and Cancer Patients: An Italian Population-Based Study

    Get PDF
    Background Since 2007 biosimilars of erythropoiesis-stimulating agents (ESAs) are available on the Italian market. Very limited post-marketing data exist on the comparative effectiveness of biosimilar and originator ESAs. Aim This population-based study was aimed to compare the effects of biosimilars, reference product and other ESAs still covered by patent on hemoglobinemia in chronic kidney disease (CKD) and cancer patients in a Local Health Unit (LHU) from Northern Italy. Methods A retrospective cohort study was conducted during the years 2009-2014 using data from Treviso LHU administrative database. Incident ESA users (no ESA dispensing within 6 months prior to treatment start, i.e. index date (ID)) with at least one hemoglobin measurement within one month prior to ID (baseline Hb value) and another measurement between 2nd and 3rd month after ID (follow-up Hb value) were identified. The strength of the consumption (as total number of defined daily dose (DDD) dispensed during the follow-up divided by days of follow-up) and the difference between follow-up and baseline Hb values [delta Hb (ΔHb)] were evaluated. Based on Hb changes, ESA users were classified as non-responders (ΔHb≤0 g/dl), responders (0Delta;Hb≤2 g/dl), and highly responders (ΔHb>2 g/ dl). A multivariate ordinal logistic regression model to identify predictors for responsiveness to treatment was performed. All analyses were stratified by indication for use and type of dispensed ESA at ID. Results Overall, 1,003 incident ESA users (reference product: 252, 25.1%; other ESAs covered by patent: 303, 30.2%; biosimilars: 448, 44.7%) with CKD or cancer were eligible for the study. No statistically significant difference in the amount of dose dispensed during the follow-up among biosimilars, reference product and other ESAs covered by patent was found in both CKD and cancer. After three months from treatment start, all ESAs increased Hb values on average by 2g/dl. No differences in ΔHb as well as in frequency of non-responders, responders and highly responders among different types of ESAs were observed in both indications of use. Overall, around 15-20% of ESA users were non-responders. Strength of treatment, but no type of dispensed ESAs was found to be predictor of responsiveness to treatment. Conclusions No difference on the effects on hemoglobinemia among users of either biosimilars or reference product or ESAs covered by patent was observed in a general population from Northern Italy, despite a comparable dispensed dose of the different ESAs during the first three months of treatment

    SHARK-NIR, the coronagraphic camera for LBT, moving toward construction

    Full text link
    SHARK-NIR is one of the two coronagraphic instruments proposed for the Large Binocular Telescope. Together with SHARK-VIS (performing coronagraphic imaging in the visible domain), it will offer the possibility to do binocular observations combining direct imaging, coronagraphic imaging and coronagraphic low resolution spectroscopy in a wide wavelength domain, going from 0.5{\mu}m to 1.7{\mu}m. Additionally, the contemporary usage of LMIRCam, the coronagraphic LBTI NIR camera, working from K to L band, will extend even more the covered wavelength range. In January 2017 SHARK-NIR underwent a successful final design review, which endorsed the instrument for construction and future implementation at LBT. We report here the final design of the instrument, which foresees two intermediate pupil planes and three focal planes to accomodate a certain number of coronagraphic techniques, selected to maximize the instrument contrast at various distances from the star. Exo-Planets search and characterization has been the science case driving the instrument design, but the SOUL upgrade of the LBT AO will increase the instrument performance in the faint end regime, allowing to do galactic (jets and disks) and extra-galactic (AGN and QSO) science on a relatively wide sample of targets, normally not reachable in other similar facilities.Comment: 8 pages, 6 figures, AO4ELT5 conference proceeding

    Neutron Majorana mass from exotic instantons

    Get PDF
    We show how a Majorana mass for the Neutron could result from non-perturbative quantum gravity effects peculiar to string theory. In particular, "exotic instantons" in un-oriented string compactifications with D-branes extending the (supersymmetric) standard model could indirectly produce an effective operator delta{m} n^t n+h.c. In a specific model with an extra vector-like pair of `quarks', acquiring a large mass proportional to the string mass scale (exponentially suppressed by a function of the string moduli fields), delta{m} can turn out to be as low as 10^{-24}-10^{-25} eV. The induced neutron-antineutron oscillations could take place with a time scale tau_{n\bar{n}} > 10^8 s, that could be tested by the next generation of experiments. On the other hand, proton decay and FCNC's are automatically strongly suppressed and are compatible with the current experimental limits. Depending on the number of brane intersections, the model may also lead to the generation of Majorana masses for R-handed neutrini. Our proposal could also suggest neutron-neutralino or neutron-axino oscillations, with implications in UCN, Dark Matter Direct Detection, UHECR and Neutron-Antineutron oscillations. This suggests to improve the limits on neutron-antineutron oscillations, as a possible test of string theory and quantum gravity.Comment: 35 pages, 11 figures. More comments on neutron-neutralino mixin

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report the first measurement of charged particle elliptic flow in Pb-Pb collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurement is performed in the central pseudorapidity region (|η\eta|<0.8) and transverse momentum range 0.2< pTp_{\rm T}< 5.0 GeV/cc. The elliptic flow signal v2_2, measured using the 4-particle correlation method, averaged over transverse momentum and pseudorapidity is 0.087 ±\pm 0.002 (stat) ±\pm 0.004 (syst) in the 40-50% centrality class. The differential elliptic flow v2(pT)_2(p_{\rm T}) reaches a maximum of 0.2 near pTp_{\rm T} = 3 GeV/cc. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow increases by about 30%. Some hydrodynamic model predictions which include viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/389

    MORFEO enters final design phase

    Full text link
    MORFEO (Multi-conjugate adaptive Optics Relay For ELT Observations, formerly MAORY), the MCAO system for the ELT, will provide diffraction-limited optical quality to the large field camera MICADO. MORFEO has officially passed the Preliminary Design Review and it is entering the final design phase. We present the current status of the project, with a focus on the adaptive optics system aspects and expected milestones during the next project phase
    corecore