464 research outputs found

    Impact of a surgical approach for implantation of durable left ventricular assist devices in patients on extracorporeal life support

    Get PDF
    Background The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. Methods A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. Results The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. Conclusion LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival

    Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report the first measurement of charged particle elliptic flow in Pb-Pb collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurement is performed in the central pseudorapidity region (|η\eta|<0.8) and transverse momentum range 0.2< pTp_{\rm T}< 5.0 GeV/cc. The elliptic flow signal v2_2, measured using the 4-particle correlation method, averaged over transverse momentum and pseudorapidity is 0.087 ±\pm 0.002 (stat) ±\pm 0.004 (syst) in the 40-50% centrality class. The differential elliptic flow v2(pT)_2(p_{\rm T}) reaches a maximum of 0.2 near pTp_{\rm T} = 3 GeV/cc. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow increases by about 30%. Some hydrodynamic model predictions which include viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/389

    Home-based palliative approach for people with severe multiple sclerosis and their carers: Study protocol for a randomized controlled trial

    Get PDF
    Background: Preliminary evidence suggests that palliative care may be useful for people with severe multiple sclerosis (MS). The aim of this study is to determine the effectiveness of a home-based palliative approach (HPA) for people with severe MS and their carers. Methods/design: This is a single-blind randomized controlled trial with a nested qualitative study. Seventy-five severe MS-carer dyads are being randomized (at three centers, one in each area of Italy) to HPA or usual care (UC) in a 2:1 ratio. Each center has a specially trained team consisting of four professionals (physician, nurse, psychologist, social worker). The team makes a comprehensive assessment of the needs of the dyads. HPA content is then agreed on, discussed with the patient's caring physician, and delivered over six months. The intervention is not intended to replace existing services. At later visits, the team checks the HPA delivery and reviews/modifies it as necessary. Discussion: The results of our study will show whether the HPA is feasible and beneficial to people with severe MS and their carers living in the three Italian geographic areas. The nested qualitative study will add to the understanding of the strengths and limitations of the intervention

    Long-range angular correlations on the near and away side in p&#8211;Pb collisions at

    Get PDF

    Effect of clinical signs, endocrinopathies, timing of surgery, hyperlipidemia, and hyperbilirubinemia on outcome in dogs with gallbladder mucocele

    Get PDF
    Gallbladder mucocele (GBM) is a common extra-hepatic biliary syndrome in dogs with death rates ranging from 7 to 45%. Therefore, the aim of this study was to identify the association of survival with variables that could be utilized to improve clinical decisions. A total of 1194 dogs with a gross and histopathological diagnosis of GBM were included from 41 veterinary referral hospitals in this retrospective study. Dogs with GBM that demonstrated abnormal clinical signs had significantly greater odds of death than subclinical dogs in a univariable analysis (OR, 4.2; 95% CI, 2.14–8.23; P < 0.001). The multivariable model indicated that categorical variables including owner recognition of jaundice (OR, 2.12; 95% CI, 1.19–3.77; P = 0.011), concurrent hyperadrenocorticism (OR 1.94; 95% CI, 1.08–3.47; P = 0.026), and Pomeranian breed (OR, 2.46; 95% CI 1.10–5.50; P = 0.029) were associated with increased odds of death, and vomiting was associated with decreased odds of death (OR, 0.48; 95% CI, 0.30–0.72; P = 0.001). Continuous variables in the multivariable model, total serum/plasma bilirubin concentration (OR, 1.03; 95% CI, 1.01–1.04; P < 0.001) and age (OR, 1.17; 95% CI, 1.08–1.26; P < 0.001), were associated with increased odds of death. The clinical utility of total serum/plasma bilirubin concentration as a biomarker to predict death was poor with a sensitivity of 0.61 (95% CI, 0.54–0.69) and a specificity of 0.63 (95% CI, 0.59–0.66). This study identified several prognostic variables in dogs with GBM including total serum/plasma bilirubin concentration, age, clinical signs, concurrent hyperadrenocorticism, and the Pomeranian breed. The presence of hypothyroidism or diabetes mellitus did not impact outcome in this study.Supplemental Table S1. Number of dogs included from each institution and years reviewed.Supplemental Table S2. Included breeds.Supplemental Table S3. Distribution of various reasons given for performing cholecystectomy in the 179 subclinical dogs with gallbladder mucocele (GBM).Supplemental Table S4. Distribution of clinical signs associated with systemic illness in 982 dogs with gallbladder mucocele.Supplemental Table S5. Distribution of reasons for death in-hospital (i.e. euthanized and died) in 179 dogs with gallbladder mucocele that underwent cholecystectomy.http://www.elsevier.com/locate/tvjlhj2020Companion Animal Clinical Studie

    Overview of the instrumentation for the Dark Energy Spectroscopic Instrument

    Get PDF
    The Dark Energy Spectroscopic Instrument (DESI) embarked on an ambitious 5 yr survey in 2021 May to explore the nature of dark energy with spectroscopic measurements of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the baryon acoustic oscillation method to measure distances from the nearby universe to beyond redshift z > 3.5, and employ redshift space distortions to measure the growth of structure and probe potential modifications to general relativity. We describe the significant instrumentation we developed to conduct the DESI survey. This includes: a wide-field, 3.°2 diameter prime-focus corrector; a focal plane system with 5020 fiber positioners on the 0.812 m diameter, aspheric focal surface; 10 continuous, high-efficiency fiber cable bundles that connect the focal plane to the spectrographs; and 10 identical spectrographs. Each spectrograph employs a pair of dichroics to split the light into three channels that together record the light from 360–980 nm with a spectral resolution that ranges from 2000–5000. We describe the science requirements, their connection to the technical requirements, the management of the project, and interfaces between subsystems. DESI was installed at the 4 m Mayall Telescope at Kitt Peak National Observatory and has achieved all of its performance goals. Some performance highlights include an rms positioner accuracy of better than 0.″1 and a median signal-to-noise ratio of 7 of the [O ii] doublet at 8 × 10−17 erg s−1 cm−2 in 1000 s for galaxies at z = 1.4–1.6. We conclude with additional highlights from the on-sky validation and commissioning, key successes, and lessons learned

    90-річчя члена-кореспондента НАН України Г.К. Степанковської

    Get PDF
    The p(T)-differential production cross section of electrons from semileptonic decays of heavy-flavor hadrons has been measured at midrapidity in proton-proton collisions at root s = 2.76 TeV in the transverse momentum range 0.5 < p(T) < 12 GeV/c with the ALICE detector at the LHC. The analysis was performed using minimum bias events and events triggered by the electromagnetic calorimeter. Predictions from perturbative QCD calculations agree with the data within the theoretical and experimental uncertainties

    Simple scoring system to predict in-hospital mortality after surgery for infective endocarditis

    Get PDF
    BACKGROUND: Aspecific scoring systems are used to predict the risk of death postsurgery in patients with infective endocarditis (IE). The purpose of the present study was both to analyze the risk factors for in-hospital death, which complicates surgery for IE, and to create a mortality risk score based on the results of this analysis. METHODS AND RESULTS: Outcomes of 361 consecutive patients (mean age, 59.1\ub115.4 years) who had undergone surgery for IE in 8 European centers of cardiac surgery were recorded prospectively, and a risk factor analysis (multivariable logistic regression) for in-hospital death was performed. The discriminatory power of a new predictive scoring system was assessed with the receiver operating characteristic curve analysis. Score validation procedures were carried out. Fifty-six (15.5%) patients died postsurgery. BMI >27 kg/m2 (odds ratio [OR], 1.79; P=0.049), estimated glomerular filtration rate 55 mm Hg (OR, 1.78; P=0.032), and critical state (OR, 2.37; P=0.017) were independent predictors of in-hospital death. A scoring system was devised to predict in-hospital death postsurgery for IE (area under the receiver operating characteristic curve, 0.780; 95% CI, 0.734-0.822). The score performed better than 5 of 6 scoring systems for in-hospital death after cardiac surgery that were considered. CONCLUSIONS: A simple scoring system based on risk factors for in-hospital death was specifically created to predict mortality risk postsurgery in patients with IE

    Centrality evolution of the charged-particle pseudorapidity density over a broad pseudorapidity range in Pb-Pb collisions at root s(NN)=2.76TeV

    Get PDF
    Peer reviewe
    corecore