1,409 research outputs found
[Determinants of the use of different healthcare levels in the General System of Social Security in Health in Colombia and the Unified Health System in Brazil].
OBJECTIVE:
To compare the use of different healthcare levels, and its determinants, in two different health systems, the General System of Social Security in Health (GSSSH) and the Unified Health System (UHS) in municipalities in Colombia and Brazil.
METHODS:
A cross-sectional study was carried out, based on a population survey in two municipalities in Colombia (n=2163) and two in Brazil (n=2155). Outcome variables consisted of the use of primary care services, outpatient secondary care services, and emergency care in the previous 3 months. Explanatory variables were need and predisposing and enabling factors. Bivariate and multivariate logistic regression analyses were performed by healthcare level and country.
RESULTS:
The determinants of use differed by healthcare level and country: having a chronic disease was associated with a greater use of primary and outpatient secondary care in Colombia, and was also associated with the use of emergency care in Brazil. In Colombia, persons enrolled in the contributory scheme more frequently used the services of the GSSSH than persons enrolled with subsidized contributions in primary and outpatient secondary care and more than persons without insurance in any healthcare level. In Brazil, the low-income population and those without private insurance more frequently used the UHS at any level. In both countries, the use of primary care was increased when persons knew the healthcare center to which they were assigned and if they had a regular source of care. Knowledge of the referral hospital increased the use of outpatient secondary care and emergency care.
CONCLUSIONS:
In both countries, the influence of the determinants of use differed according to the level of care used, emphasizing the need to analyze healthcare use by disaggregating it by level of care
LEMUR: Large European Module for solar Ultraviolet Research. European contribution to JAXA's Solar-C mission
Understanding the solar outer atmosphere requires concerted, simultaneous
solar observations from the visible to the vacuum ultraviolet (VUV) and soft
X-rays, at high spatial resolution (between 0.1" and 0.3"), at high temporal
resolution (on the order of 10 s, i.e., the time scale of chromospheric
dynamics), with a wide temperature coverage (0.01 MK to 20 MK, from the
chromosphere to the flaring corona), and the capability of measuring magnetic
fields through spectropolarimetry at visible and near-infrared wavelengths.
Simultaneous spectroscopic measurements sampling the entire temperature range
are particularly important.
These requirements are fulfilled by the Japanese Solar-C mission (Plan B),
composed of a spacecraft in a geosynchronous orbit with a payload providing a
significant improvement of imaging and spectropolarimetric capabilities in the
UV, visible, and near-infrared with respect to what is available today and
foreseen in the near future.
The Large European Module for solar Ultraviolet Research (LEMUR), described
in this paper, is a large VUV telescope feeding a scientific payload of
high-resolution imaging spectrographs and cameras. LEMUR consists of two major
components: a VUV solar telescope with a 30 cm diameter mirror and a focal
length of 3.6 m, and a focal-plane package composed of VUV spectrometers
covering six carefully chosen wavelength ranges between 17 and 127 nm. The
LEMUR slit covers 280" on the Sun with 0.14" per pixel sampling. In addition,
LEMUR is capable of measuring mass flows velocities (line shifts) down to 2
km/s or better.
LEMUR has been proposed to ESA as the European contribution to the Solar C
mission.Comment: 35 pages, 14 figures. To appear on Experimental Astronom
Dise?o, construcci?n y equipamiento del Hospital Materno Infantil El Carmen de Jun?n
El proyecto tiene como meta dise?ar, construir y equipar el Hospital Materno Infantil El Carmen de Jun?n de categor?a E-III, cuenta con tres objetivos de eficiencia: (i) cumplir con la fecha de t?rmino del proyecto seg?n cronograma de obra el 05 de febrero del 2020, tomando como referencia el inicio del proyecto el 02 de noviembre del 2017, (ii) cumplir con el presupuesto de S/ 148?263,232.40; y, (iii) lograr el 95% de aceptaci?n de los entregables del proyecto al momento de la transferencia al Gobierno Regional de Jun?n, y la subsanaci?n del 100 % de las No Conformidades para la recepci?n y entrega de obra. Asimismo, tiene dos objetivos relacionados con el producto: (i) instalar el equipamiento m?dico seg?n cronograma de obra el 15 de junio del 2019; y, (ii) realizar la construcci?n del Bloque 1: Bloque Cl?nico, Bloque 2: Ambulatorio y de Hospitalizaci?n, Bloque 3: Servicios Generales T?cnicos y de Soporte del Hospital, Bloque 4: Exteriores - Estacionamiento, seg?n cronograma de obra el 26 de enero del 2020
Toothache and associated factors in Brazilian adults: a cross-sectional population-based study
Extent: 8p.Background: Toothache is a dental public health problem and one of the predictors of dental attendance and it is strongly associated with the life quality of individuals. In spite of this, there are few population-based epidemiological studies on this theme. Objective: To estimate the prevalence of toothache and associated factors in adults of Lages, Southern Brazil. Methods: A cross-sectional population-based study was carried out in a sample of 2,022 adults aged 20 to 59 years living in the urban area of a medium sized city in Southern Brazil. A questionnaire including socioeconomic, demographic, smoking, alcohol, and use of dental service variables was applied at adults household. Toothache occurred six months previous of the interview was considered the outcome. Poisson regression analyses were performed following a theoretical hierarchical framework. All analysis was adjusted by the sample design effect. Results: The response rate was 98.6%. The prevalence of toothache was 18.0% (95% CI 16.0; 20.1). The following variables were associated with toothache after adjustment: female (PR = 1.3 95% CI 1.3; 2.0), black skin colour vs. whites (PR = 1.5 95% CI 1.1, 1.9), low per capita income (PR = 1.7 95% CI 1.2, 2.3), smokers (PR = 1.5 95% CI 1.2, 1.9) and those who reported alcohol problems (PR = 1.4 95% CI 1.1; 1.9). To be 40 years of age (PR = 0.5 95% CI 0.4, 0.7) and use dental service in the last year (RR = 0.5 95% CI 0.4, 0.6) were protective factors for toothache. Conclusion: The prevalence of toothache in adults of Lages can be considered a major problem of dental public health.Mirian Kuhnen, Marco A Peres, Anelise V Masiero and Karen G Pere
Niobium and niobium-iron coatings on API 5LX 70 steel applied with HVOF
The present study aimed to create and characterize niobium and niobium-iron60% coatings applied to steel API 5L X70 using the hypersonic thermal spray process (HVOF). The morphologies of the coatings were analyzed using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), X-ray diffraction (XRD) and profilometry, while the coatingsâ hardnesses was evaluated using the Vickers hardness test. The coatingsâ corrosion resistance was evaluated by monitoring their open circuit potential and potentiodynamic polarization and performing electrochemical impedance spectroscopy in a 0.05 M NaCl solution. The results showed that the niobium-iron coating contained minor porosity regions, while such defects occurred over large regions of the niobium coating. In terms of corrosion resistance, the coatings obtained in this work promoted a reduction in the substrateâs corrosion rate, but the presence of discontinuities such as porosity compromised the barrier effects of these coatings
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
- âŚ