1,958 research outputs found

    Operating theatre quality and prevention of surgical site infections

    Get PDF
    Surgical site infections (SSI) account for 14% to 17% of all hospital-acquired infections and 38% of nosocomial infections in surgical patients. SSI remain a substantial cause of morbid- ity and death, possibly because of the larger numbers of elderly surgical patients or those with a variety of chronic and immuno- compromising conditions, and emergence of antibiotic-resistant microorganisms. Factors causing surgical site infection are multifarious. Several studies have identified the main patient-related (endogenous risk factors) and procedure-related (external risk factors) factors that influence the risk of SSI. The rate of surgical wound infections is strongly influenced by operating theatre quality, too. A safe and salubrious operating theatre is an environment in which all sources of pollution and any micro-environmental alterations are kept strictly under control. This can be achieved only through careful planning, maintenance and periodic checks, as well as proper ongoing training for staff. Many international scientific societies have produced guidelines regarding the environmental features of operating theatres (posi- tive pressure, exchanges of filtered air per hour, air-conditioning systems with HEPA filters, etc.) and issued recommendations on healthcare-associated infection, including SSI, concerning surveillance methods, intervention to actively prevent SSI and approaches to monitoring the implementation of such strategies. Therefore, the prevention of SSI requires a multidisciplinary approach and the commitment of all concerned, including that of those who are responsible for the design, layout and functioning of operating theatres

    How dynamic are ice-stream beds?

    Get PDF
    Projections of sea-level rise contributions from West Antarctica's dynamically thinning ice streams contain high uncertainty because some of the key processes involved are extremely challenging to observe. An especially poorly observed parameter is sub-decadal stability of ice-stream beds, which may be important for subglacial traction, till continuity and landform development. Only two previous studies have made repeated geophysical measurements of ice-stream beds at the same locations in different years, but both studies were limited in spatial extent. Here, we present the results from repeat radar measurements of the bed of Pine Island Glacier, West Antarctica, conducted 3–6 years apart, along a cumulative ∼ 60 km of profiles. Analysis of the correlation of bed picks between repeat surveys shows that 90 % of the bed displays no significant change despite the glacier increasing in speed by up to 40 % over the last decade. We attribute the negligible detection of morphological change at the bed of Pine Island Glacier to the ubiquitous presence of a deforming till layer, wherein sediment transport is in steady state, such that sediment is transported along the basal interface without inducing morphological change to the radar-sounded basal interface. Given the precision of our measurements, the upper limit of subglacial erosion observed here is 500 mm a‾¹, far exceeding erosion rates reported for glacial settings from proglacial sediment yields, but substantially below subglacial erosion rates of 1.0 m a‾¹ previously reported from repeat geophysical surveys in West Antarctica

    Environmental monitoring programme in the cell therapy facility of a research centre: preliminary investigation

    Get PDF
    Introduction. Recent discoveries in cell therapy research present new opportunities for cellular products to be used to treat severe, and as yet incurable, diseases. It is therefore essential to implement a quality control programme in order to ensure that safe cells and tissues are provided. Methods. In a preliminary phase of the setting up of a the cell factory, monitoring was carried out monthly over a 6-month period in one out of three cell therapy laboratories and filter rooms in order to evaluate the microbial contamination of air and surfaces and the presence of airborne particulates. Results. The mean total bacterial and fungal loads measured in the air in the centre of the filter room were 20.7 ± 28.9 colonyforming units (cfu)/m3 and 9.2 ± 15.4 cfu/m3, respectively, and 5.2 ± 4.1 cfu/m3 and 6.8 ± 13.4 cfu/m3, respectively, in the laboratory. The mean fungal load values recorded on the surfaces sampled in the laboratory were in 6 out of 18 cases higher than the reference values (5 cfu/plate). As to the results of particulate monitoring, with regard to the 0.5 ?m particles, about 83% of the samples revealed values below the limit of 350.000 particles per cubic metre. Conclusions. In this set-up phase, monitoring was able to pick out structural and organisational flaws acceptable in a laboratory compliant with Good Manufacturing Practices class C (Annex 1), but not in a class B facility. Thanks to this preliminary monitoring phase, and by correcting these flaws, the clean room facility could achieve compliance to class B

    Clinical experience with ipilimumab 10 mg/kg in patients with melanoma treated at Italian centres as part of a European expanded access programme

    Get PDF
    Background: Patients with advanced melanoma are faced with a poor prognosis and, until recently, limited treatment options. Ipilimumab, a novel immunotherapy that blocks cytotoxic T-lymphocyte-associated antigen-4, was the first agent to improve survival of patients with advanced melanoma in a randomised, controlled phase 3 trial. We used data from an expanded access programme (EAP) at Italian centres to evaluate the clinical activity and safety profile of ipilimumab 10 mg/kg in patients with advanced melanoma in a setting more similar to that of daily practice. Methods. Data were collected from patients enrolled in an ipilimumab EAP across eight participating Italian centres. As per the EAP protocol, patients had life-threatening, unresectable stage III/IV melanoma, had failed or did not tolerate previous treatments and had no other therapeutic option available. Treatment comprised ipilimumab 10 mg/kg every 3 weeks for a total of four doses. If physicians believed patients would continue to derive benefit from ipilimumab treatment, maintenance therapy with ipilimumab 10 mg/kg was provided every 12 weeks. Tumour responses were assessed every 12 weeks using modified World Health Organization criteria and safety continuously monitored. Results: Seventy-four pretreated patients with advanced melanoma were treated with ipilimumab 10 mg/kg. Of these, 9 (13.0%) had an objective response, comprising 3 patients with a complete response and 6 with a partial response. Median overall survival was 7.0 months (95% confidence interval, 5.3-8.7) and 16.6% of patients were alive after 3 years. Forty-five patients (60.8%) reported treatment-related adverse events of any grade, which were most commonly low-grade pruritus, pain, fever and diarrhoea. Grade 3 or 4 treatment-related AEs were reported in 8 patients (10.8%). Conclusions: The clinical activity and safety profile of ipilimumab 10 mg/kg in the EAP was similar to that seen in previous clinical trials of ipilimumab in pretreated patient populations. © 2013 Altomonte et al.; licensee BioMed Central Ltd

    On the size and shape of drumlins

    Full text link

    Hypersensitivity pneumonitis: an overlooked cause of cough and dyspnea.

    Get PDF
    Hypersensitivity pneumonitis (HP) is an immune-mediated pulmonary disorder involving inflammation of the lung interstitium, terminal bronchioles, and alveoli caused by the immune response to the inhalation of an offending environmental airborne agent. It can manifest as exertional dyspnea, fatigue, weight loss, and progressive respiratory failure if left untreated. Because of its protean features, it can be misdiagnosed as other common obstructive lung conditions such as asthma. If triggers are not avoided, it can progress to irreversible pulmonary fibrosis. In this article, we present the case of a 51-year-old male who presented to our hospital with recurrent bouts of dyspnea and cough, initially diagnosed as an asthma exacerbation. He received a final diagnosis of HP after investigation of his workplace revealed airborne spores and surface molds from multiple fungal species, serology revealed eosinophilia, and computed tomography showed bronchiectasis. Avoidance of occupational exposure resulted in significant improvement of his respiratory symptoms after two months

    Lung microbiome in idiopathic pulmonary fibrosis and other interstitial lung diseases

    Get PDF
    Interstitial lung diseases represent a heterogeneous and wide group of diseases in which factors leading to disease initiation and progression are not fully understood. Recent evidence suggests that the lung microbiome might influence the pathogenesis and progression of interstitial lung diseases. In recent years, the utilization of culture-independent methodologies has allowed the identification of complex and dynamic communities of microbes, in patients with interstitial lung diseases. However, the potential mechanisms by which these changes may drive disease pathogenesis and progression are largely unknown. The aim of this review is to discuss the role of the altered lung microbiome in several interstitial lung diseases. Untangling the host–microbiome interaction in the lung and airway of interstitial lung disease patients is a research priority. Thus, lung dysbiosis is a potentially treatable trait across several interstitial lung diseases, and its proper characterization and treatment might be crucial to change the natural history of these diseases and improve outcomes

    Measurement of the B+ and B-0 lifetimes and search for CP(T) violation using reconstructed secondary vertices

    Get PDF
    The lifetimes of the B+ and B-0 mesons, and their ratio, have been measured in the OPAL experiment using 2.4 million hadronic Z(0) decays recorded at LEP. Z(0) --> b (b) over bar decays were tagged using displaced secondary vertices and high momentum electrons and muons. The lifetimes were then measured using well-reconstructed charged and neutral secondary vertices selected in this tagged data sample. The results aretau(B+) = 1.643 +/- 0.037 +/- 0.025 pstau(Bo) = 1.523 +/- 0.057 +/- 0.053 pstau(B+)/tau(Bo) = 1.079 +/- 0.064 +/- 0.041,where in each case the first error is statistical and the second systematic.A larger data sample of 3.1 million hadronic Z(o) decays has been used to search for CP and CPT violating effects by comparison of inclusive b and (b) over bar hadron decays, No evidence fur such effects is seen. The CP violation parameter Re(epsilon(B)) is measured to be Re(epsilon(B)) = 0.001 +/- 0.014 +/- 0.003and the fractional difference between b and (b) over bar hadron lifetimes is measured to(Delta tau/tau)(b) = tau(b hadron) - tau((b) over bar hadron)/tau(average) = -0.001 +/- 0.012 +/- 0.008

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente
    corecore