870 research outputs found

    Actinomadura meyerae osteitis following wound contamination with hay in a woman in France: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Mycetoma is a chronic granulomatous infection caused by environmental fungi or bacteria. It affects dermal and subcutaneous tissues, with putative contiguous extension to muscles or bones. While common in tropical and subtropical areas, mycetoma is rare in Europe.</p> <p>Case presentation</p> <p>We describe a case of <it>Actinomadura meyerae </it>osteitis in a 49-year-old Caucasian woman who suffered a tibia open fracture contaminated with hay; to the best of our knowledge the first case of autochthonous <it>A. meyerae </it>infection reported in France. The bacterium was cultivated from a bone biopsy. Following surgical osteosynthesis and six months of treatment with cotrimoxazole, our patient made a full recovery.</p> <p>Conclusion</p> <p>Our case report suggests that <it>A. meyerae </it>is a potential agent of wound infection in farm workers in contact with hay.</p

    Runge-Kutta residual distribution schemes

    Get PDF
    We are concerned with the solution of time-dependent non-linear hyperbolic partial differential equations. We investigate the combination of residual distribution methods with a consistent mass matrix (discretisation in space) and a Runge–Kutta-type time-stepping (discretisation in time). The introduced non-linear blending procedure allows us to retain the explicit character of the time-stepping procedure. The resulting methods are second order accurate provided that both spatial and temporal approximations are. The proposed approach results in a global linear system that has to be solved at each time-step. An efficient way of solving this system is also proposed. To test and validate this new framework, we perform extensive numerical experiments on a wide variety of classical problems. An extensive numerical comparison of our approach with other multi-stage residual distribution schemes is also given

    Treatment of reducible unstable fractures of the distal radius in adults: a randomised controlled trial of De Palma percutaneous pinning versus bridging external fixation

    Get PDF
    Background: At present, there is no conclusive evidence regarding the best treatment method for reducible unstable fractures of the distal radius. This study compared the effectiveness of two methods used in surgical treatment of such fractures: percutaneous pinning and external fixation.Methods: We randomly allocated 100 patients into two groups treated surgically with modified de Palma percutaneous pinning and bridging external fixation. Independent but not blinded evaluators administered the DASH quality-of-life questionnaire at postoperative months 6 and 24, performed functional assessment of pain, range of motion, and palm grip strength, and radiographic examinations (volar and radial angle, and height of the radius) before the operation, immediately afterwards, and at 6 and 24 months postoperative. Modified de Palma percutaneous pinning patients used an above-elbow cast whereas external fixation group had unrestricted elbow motion after surgery. Patients who for any reason demonstrated treatment failure or required additional interventions were followed up and their results were included in the group into which these patients had initially been randomised according to the intention-to-treat principle. A significance level of 5% (alpha = 0.05). was used for all statistical tests, such that tests presenting a p-value less than 0.05 were considered statistically significant.Results: Ninety one (58.8 mean age and 66 participants were female) were included in the final assessment at 24 months. the DASH questionnaire evaluation showed a statistically significant result favouring the de Palma group (mean difference = -7.1 p = 0.044) after six months, but this was not maintained at 24 months. There were no statistically differences between the groups with respect to palm grip strength. Analysis of the range-of-motion limitation index (uninjured side minus affected side motion of) showed a statistical difference (mean difference = 2.4 p = 0.043) favoring the external fixator group with regard to the supination movement 6 months after the operation; however, this was not maintained at 24 months. the final results of the radiographic evaluation were similar for the two groups. Overall, five patients developed complications: two with de Palma pinning and three with external fixation.Conclusion: There was a small statistically significant difference favouring the de Palma method in early functional at 6 months according to the DASH questionnaire, and for supination movement favouring the fixator group. However, both were not clinical relevant. By 24 months the groups were similar for all outcome

    Troublesome Heterotopic Ossification after Central Nervous System Damage: A Survey of 570 Surgeries

    Get PDF
    BACKGROUND: Heterotopic ossification (HO) is a frequent complication after central nervous system (CNS) damage but has seldom been studied. We aimed to investigate features of HO for the first time in a large sample and the rate of early recurrence of HO in terms of the time of surgery. METHODOLOGY/PRINCIPAL FINDINGS: We retrospectively analyzed data from an anonymous prospective survey of patients undergoing surgery between May 1993 and November 2009 in our institution for troublesome HO related to acquired neurological disease. Demographic and HO characteristics and neurological etiologies were recorded. For 357 consecutive patients, we collected data on 539 first surgeries for HO (129 surgeries for multiple sites). During the follow-up, recurrences requiring another surgery appeared in 31 cases (5.8% [31/539]; 95% confidence interval [CI]: 3.8%-7.8%; 27 patients). Most HO requiring surgery occurred after traumatic brain injury (199 patients [55.7%]), then spinal cord injury (86 [24.0%]), stroke (42 [11.8%]) and cerebral anoxia (30 [8.6%]). The hip was the primary site of HO (328 [60.9%]), then the elbow (115 [21.3%]), knee (77 [14.3%]) and shoulder (19 [3.5%]). For all patients, 181 of the surgeries were performed within the first year after the CNS damage, without recurrence of HO. Recurrence was not associated with etiology (p = 0.46), sex (p = 1.00), age at CNS damage (p = 0.2), multisite localization (p = 0.34), or delay to surgery (p = 0.7). CONCLUSIONS/SIGNIFICANCE: In patients with CNS damage, troublesome HO and recurrence occurs most frequently after traumatic brain injury and appears frequently in the hip and elbow. Early surgery for HO is not a factor of recurrence

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …
    corecore