101 research outputs found

    Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-opera- tive morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilites by observ- ing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted in- struments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This paper reviews the state-of-the-art methods for optical intra-operative 3D reconstruction in laparoscopic surgery and discusses the technical challenges and future perspectives towards clinical translation. With the recent paradigm shift of surgical practice towards MIS and new developments in 3D opti- cal imaging, this is a timely discussion about technologies that could facilitate complex CAS procedures in dynamic and deformable anatomical regions

    Image-guided port placement for minimally invasive cardiac surgery

    Get PDF
    Minimally invasive surgery is becoming popular for a number of interventions. Use of robotic surgical systems in coronary artery bypass intervention offers many benefits to patients, but is however limited by remaining challenges in port placement. Choosing the entry ports for the robotic tools has a large impact on the outcome of the surgery, and can be assisted by pre-operative planning and intra-operative guidance techniques. In this thesis, pre-operative 3D computed tomography (CT) imaging is used to plan minimally invasive robotic coronary artery bypass (MIRCAB) surgery. From a patient database, port placement optimization routines are implemented and validated. Computed port placement configurations approximated past expert chosen configurations with an error of 13.7 ±5.1 mm. Following optimization, statistical classification was used to assess patient candidacy for MIRCAB. Various pattern recognition techniques were used to predict MIRCAB success, and could be used in the future to reduce conversion rates to conventional open-chest surgery. Gaussian, Parzen window, and nearest neighbour classifiers all proved able to detect ‘candidate’ and ‘non-candidate’ MIRCAB patients. Intra-operative registration and laser projection of port placements was validated on a phantom and then evaluated in four patient cases. An image-guided laser projection system was developed to map port placement plans from pre-operative 3D images. Port placement mappings on the phantom setup were accurate with an error of 2.4 ± 0.4 mm. In the patient cases, projections remained within 1 cm of computed port positions. Misregistered port placement mappings in human trials were due mainly to the rigid-body registration assumption and can be improved by non-rigid techniques. Overall, this work presents an integrated approach for: 1) pre-operative port placement planning and classification of incoming MIRCAB patients; and 2) intra-operative guidance of port placement. Effective translation of these techniques to the clinic will enable MIRCAB as a more efficacious and accessible procedure

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Multi Modality Brain Mapping System (MBMS) Using Artificial Intelligence and Pattern Recognition

    Get PDF
    A Multimodality Brain Mapping System (MBMS), comprising one or more scopes (e.g., microscopes or endoscopes) coupled to one or more processors, wherein the one or more processors obtain training data from one or more first images and/or first data, wherein one or more abnormal regions and one or more normal regions are identified; receive a second image captured by one or more of the scopes at a later time than the one or more first images and/or first data and/or captured using a different imaging technique; and generate, using machine learning trained using the training data, one or more viewable indicators identifying one or abnormalities in the second image, wherein the one or more viewable indicators are generated in real time as the second image is formed. One or more of the scopes display the one or more viewable indicators on the second image

    OPTICAL NAVIGATION TECHNIQUES FOR MINIMALLY INVASIVE ROBOTIC SURGERIES

    Get PDF
    Minimally invasive surgery (MIS) involves small incisions in a patient's body, leading to reduced medical risk and shorter hospital stays compared to open surgeries. For these reasons, MIS has experienced increased demand across different types of surgery. MIS sometimes utilizes robotic instruments to complement human surgical manipulation to achieve higher precision than can be obtained with traditional surgeries. Modern surgical robots perform within a master-slave paradigm, in which a robotic slave replicates the control gestures emanating from a master tool manipulated by a human surgeon. Presently, certain human errors due to hand tremors or unintended acts are moderately compensated at the tool manipulation console. However, errors due to robotic vision and display to the surgeon are not equivalently addressed. Current vision capabilities within the master-slave robotic paradigm are supported by perceptual vision through a limited binocular view, which considerably impacts the hand-eye coordination of the surgeon and provides no quantitative geometric localization for robot targeting. These limitations lead to unexpected surgical outcomes, and longer operating times compared to open surgery. To improve vision capabilities within an endoscopic setting, we designed and built several image guided robotic systems, which obtained sub-millimeter accuracy. With this improved accuracy, we developed a corresponding surgical planning method for robotic automation. As a demonstration, we prototyped an autonomous electro-surgical robot that employed quantitative 3D structural reconstruction with near infrared registering and tissue classification methods to localize optimal targeting and suturing points for minimally invasive surgery. Results from validation of the cooperative control and registration between the vision system in a series of in vivo and in vitro experiments are presented and the potential enhancement to autonomous robotic minimally invasive surgery by utilizing our technique will be discussed

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Intraoperative Endoscopic Augmented Reality in Third Ventriculostomy

    Get PDF
    In neurosurgery, as a result of the brain-shift, the preoperative patient models used as a intraoperative reference change. A meaningful use of the preoperative virtual models during the operation requires for a model update. The NEAR project, Neuroendoscopy towards Augmented Reality, describes a new camera calibration model for high distorted lenses and introduces the concept of active endoscopes endowed with with navigation, camera calibration, augmented reality and triangulation modules
    corecore