1,144 research outputs found

    Adaptive FDG-PET/CT guided dose escalation in head and neck squamous cell carcinoma: Late toxicity and oncologic outcomes (The ADMIRE study)

    Get PDF
    PURPOSE: To report on the late toxicity and local control (LC) of head and neck cancer patients treated with adaptive FDG-PET/CT response-guided radiotherapy (ADMIRE) with dose escalation (NCT03376386). MATERIALS AND METHODS: Between December 2017 and April 2019, 20 patients with stage II-IV squamous cell carcinoma of the larynx, hypopharynx or oropharynx were treated within the ADMIRE study where FDG-PET/CT response-guided (Week 2&4) dose escalation was applied (total dose 70-78 Gy). Cisplatin or cetuximab was added to radiotherapy in case of T3-4 and/or N2c disease. To compare the LC and late toxicity of the study population, we used an external control group (n = 67) consisting of all eligible patients for the study (but not participated). These patients were treated in our institution during the same period with the current standard of 70 Gy radiotherapy. To reduce the effect of confounding, logistic regression analyses was done using stabilized inverse probability of treatment weighting (SIPTW). RESULTS: After median follow-up of 40 and 43 months for the ADMIRE and control groups, the 3-year LC-rates were 74% and 78%, respectively (adjusted HR after SIPTW 0.80, 95 %CI 0.25-2.52, p = 0.70). The incidences of any late G3 toxicity were 35% and 18%, respectively. The adjusted OR for any late G3 toxicity was 5.09 (95 %CI 1.64-15.8, p = 0.005), for any late G ≄ 2 toxicity was 3.67 (95 %CI 1.2-11.7, p = 0.02), for persistent laryngeal edema was 10.95 (95% CI 2.71-44.29, p = 0.001), for persistent mucosal ulcers was 4.67 (95% CI 1.23-17.7, p = 0.023), and for late G3 radionecrosis was 15.69 (95 %CI 2.43-101.39, p = 0.004). CONCLUSION: Given the comparable LC rates with increased late toxicity in the ADMIRE group, selection criteria for future adaptive dose escalation trials (preferably randomized) need to be refined to include only patients at higher risk of local failure and/or lower risk of severe late toxicity

    National Protocol for Model-Based Selection for Proton Therapy in Head and Neck Cancer

    Get PDF
    In the Netherlands, the model-based approach is used to identify patients with head and neck cancer who may benefit most from proton therapy in terms of prevention of late radiation-induced side effects in comparison with photon therapy. To this purpose, a National Indication Protocol Proton therapy for Head and Neck Cancer patients (NIPP-HNC) was developed, which has been approved by the health care authorities. When patients qualify according to the guidelines of the NIPP-HNC, proton therapy is fully reimbursed. This article describes the procedures that were followed to develop this NIPP-HNC and provides all necessary information to introduce model-based selection for patients with head and neck cancer into routine clinical practice.</p

    Independent position correction on tumor and lymph nodes; consequences for bladder cancer irradiation with two combined IMRT plans

    Get PDF
    Abstract Background The application of lipiodol injections as markers around bladder tumors combined with the use of CBCT for image guidance enables daily on-line position correction based on the position of the bladder tumor. However, this might introduce the risk of underdosing the pelvic lymph nodes. In this study several correction strategies were compared. Methods For this study set-up errors and tumor displacements for ten complete treatments were generated; both were based on the data of 10 bladder cancer patients. Besides, two IMRT plans were made for 20 patients, one for the elective field and a boost plan for the tumor. For each patient 10 complete treatments were simulated. For each treatment the dose was calculated without position correction (option 1), correction on bony anatomy (option 2), on tumor only (option 3) and separately on bone for the elective field (option 4). For each method we analyzed the D99% for the tumor, bladder and lymph nodes and the V95% for the small intestines, rectum, healthy part of the bladder and femoral heads. Results CTV coverage was significantly lower with options 1 and 2. With option 3 the tumor coverage was not significantly different from the treatment plan. The ΔD99% (D99%, option n - D99%, treatment plan) for option 4 was small, but significant. For the lymph nodes the results from option 1 differed not significantly from the treatment plan. The median ΔD99% of the other options were small, but significant. ΔD99% for PTVbladder was small for options 1, 2 and 4, but decreased up to -8.5 Gy when option 3 was applied. Option 4 is the only method where the difference with the treatment plan never exceeds 2 Gy. The V95% for the rectum, femoral heads and small intestines was small in the treatment plan and this remained so after applying the correction options, indicating that no additional hot spots occurred. Conclusions Applying independent position correction on bone for the elective field and on tumor for the boost separately gives on average the best target coverage, without introducing additional hot spots in the healthy tissue.</p

    The effect of on-line position correction on the dose distribution in focal radiotherapy for bladder cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to determine the dosimetric effect of on-line position correction for bladder tumor irradiation and to find methods to predict and handle this effect.</p> <p>Methods</p> <p>For 25 patients with unifocal bladder cancer intensity modulated radiotherapy (IMRT) with 5 beams was planned. The requirement for each plan was that 99% of the target volume received 95% of the prescribed dose. Tumor displacements from -2.0 cm to 2.0 cm in each dimension were simulated, using 0.5 cm increments, resulting in 729 simulations per patient. We assumed that on-line correction for the tumor was applied perfectly. We determined the correlation between the change in D<sub>99% </sub>and the change in path length, which is defined here as the distance from the skin to the isocenter for each beam. In addition the margin needed to avoid underdosage was determined and the probability that an underdosage occurs in a real treatment was calculated.</p> <p>Results</p> <p>Adjustments for tumor displacement with perfect on-line position correction resulted in an altered dose distribution. The altered fraction dose to the target varied from 91.9% to 100.4% of the prescribed dose. The mean D<sub>99% </sub>(± SD) was 95.8% ± 1.0%. There was a modest linear correlation between the difference in D<sub>99% </sub>and the change in path length of the beams after correction (R<sup>2 </sup>= 0.590). The median probability that a systematic underdosage occurs in a real treatment was 0.23% (range: 0 - 24.5%). A margin of 2 mm reduced that probability to < 0.001% in all patients.</p> <p>Conclusion</p> <p>On-line position correction does result in an altered target coverage, due to changes in average path length after position correction. An extra margin can be added to prevent underdosage.</p

    Measurement of the top quark forward-backward production asymmetry and the anomalous chromoelectric and chromomagnetic moments in pp collisions at √s = 13 TeV

    Get PDF
    Abstract The parton-level top quark (t) forward-backward asymmetry and the anomalous chromoelectric (d̂ t) and chromomagnetic (Ό̂ t) moments have been measured using LHC pp collisions at a center-of-mass energy of 13 TeV, collected in the CMS detector in a data sample corresponding to an integrated luminosity of 35.9 fb−1. The linearized variable AFB(1) is used to approximate the asymmetry. Candidate t t ÂŻ events decaying to a muon or electron and jets in final states with low and high Lorentz boosts are selected and reconstructed using a fit of the kinematic distributions of the decay products to those expected for t t ÂŻ final states. The values found for the parameters are AFB(1)=0.048−0.087+0.095(stat)−0.029+0.020(syst),Ό̂t=−0.024−0.009+0.013(stat)−0.011+0.016(syst), and a limit is placed on the magnitude of | d̂ t| &lt; 0.03 at 95% confidence level. [Figure not available: see fulltext.

    An embedding technique to determine ττ backgrounds in proton-proton collision data

    Get PDF
    An embedding technique is presented to estimate standard model tau tau backgrounds from data with minimal simulation input. In the data, the muons are removed from reconstructed mu mu events and replaced with simulated tau leptons with the same kinematic properties. In this way, a set of hybrid events is obtained that does not rely on simulation except for the decay of the tau leptons. The challenges in describing the underlying event or the production of associated jets in the simulation are avoided. The technique described in this paper was developed for CMS. Its validation and the inherent uncertainties are also discussed. The demonstration of the performance of the technique is based on a sample of proton-proton collisions collected by CMS in 2017 at root s = 13 TeV corresponding to an integrated luminosity of 41.5 fb(-1).Peer reviewe

    Measurement of t(t)over-bar normalised multi-differential cross sections in pp collisions at root s=13 TeV, and simultaneous determination of the strong coupling strength, top quark pole mass, and parton distribution functions

    Get PDF
    Peer reviewe

    Measurement of the azimuthal anisotropy of Y(1S) and Y(2S) mesons in PbPb collisions at root s(NN)=5.02 TeV

    Get PDF
    The second-order Fourier coefficients (v(2)) characterizing the azimuthal distributions of Y(1S) and Y(2S) mesons produced in PbPb collisions at root s(NN) = 5.02 TeV are studied. The Y mesons are reconstructed in their dimuon decay channel, as measured by the CMS detector. The collected data set corresponds to an integrated luminosity of 1.7 nb(-1). The scalar product method is used to extract the v2 coefficients of the azimuthal distributions. Results are reported for the rapidity range vertical bar y vertical bar < 2.4, in the transverse momentum interval 0 < pT < 50 GeV/c, and in three centrality ranges of 10-30%, 30-50% and 50-90%. In contrast to the J/psi mesons, the measured v(2) values for the Y mesons are found to be consistent with zero. (C) 2021 The Author(s). Published by Elsevier B.V.Peer reviewe

    Search for Physics beyond the Standard Model in Events with Overlapping Photons and Jets

    Get PDF
    Results are reported from a search for new particles that decay into a photon and two gluons, in events with jets. Novel jet substructure techniques are developed that allow photons to be identified in an environment densely populated with hadrons. The analyzed proton-proton collision data were collected by the CMS experiment at the LHC, in 2016 at root s = 13 TeV, and correspond to an integrated luminosity of 35.9 fb(-1). The spectra of total transverse hadronic energy of candidate events are examined for deviations from the standard model predictions. No statistically significant excess is observed over the expected background. The first cross section limits on new physics processes resulting in such events are set. The results are interpreted as upper limits on the rate of gluino pair production, utilizing a simplified stealth supersymmetry model. The excluded gluino masses extend up to 1.7 TeV, for a neutralino mass of 200 GeV and exceed previous mass constraints set by analyses targeting events with isolated photons.Peer reviewe

    Calibration of the CMS hadron calorimeters using proton-proton collision data at root s=13 TeV

    Get PDF
    Methods are presented for calibrating the hadron calorimeter system of theCMSetector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities vertical bar eta vertical bar ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.Peer reviewe
    • 

    corecore