448 research outputs found

    Literature review and analysis of the development of health outcomes assessment instruments in Chinese medicine

    Full text link
    OBJECTIVE: To evaluate the development of health outcomes assessment instruments in Chinese medicine. METHODS: A comprehensive literature search for all published articles in China National Knowledge Infrastructure Database, Chongqing VIP Database and WANFANG Data was conducted. The studies that met the inclusion and exclusion criteria were used to extract information according to a predesigned assessment instrument. RESULTS: A total of 97 instruments for health outcome assessment in Chinese medicine were identified. Of these questionnaires, 7 were generic, 12 were condition-specific and 78 were disease-specific. All instruments were suitable for adults, children, and both men and women. These instruments aimed to evaluate the health-related quality of life, signs and symptoms as well as patient satisfaction and doctor-reported outcome. However, the descriptions were poorly constructed for some of the most basic parameters, such as the domains and items, administrative mode, response options, memory recall periods, burden evaluation, format, copyright, content validity, and other properties. CONCLUSION: The instrument development for health outcomes assessment in Chinese medicine is increasing rapidly; however, there are many limitations in current methodologies and standards, and further studies are needed. © 2013 Feng-bin Liu et al

    Literature review and analysis of the application of health outcome assessment instruments in Chinese medicine

    Full text link
    OBJECTIVE: To evaluate the application of health assessment instruments in Chinese medicine. METHODS: According to a pre-defined search strategy, a comprehensive literature search for all articles published in China National Knowledge Infrastructure databases was conducted. The resulting articles that met the defined inclusion and exclusion criteria were used for analysis. RESULTS: A total of 97 instruments for health outcome assessment in Chinese medicine have been used in fundamental and theoretical research, and 14 of these were also used in 29 clinical trials that were randomized controlled trials, or descriptive or cross-sectional studies. In 2 152 Chinese medicine-based studies that used instruments in their methodology, more than 150 questionnaires were identified. Among the identified questionnaires, 51 were used in more than 10 articles (0.5%). Most of these instruments were developed in Western countries and few studies (4%) used the instrument as the primary evidence for their conclusions. CONCLUSION: Usage of instruments for health outcome assessment in Chinese medicine is increasing rapidly; however, current limitations include selection rationale, result interpretation and standardization, which must be addressed accordingly

    Semimetallic carbon allotrope with topological nodal line in mixed sp2sp^2-sp3sp^3 bonding networks

    Full text link
    Graphene is known as a two-dimensional Dirac semimetal, in which electron states are described by the Dirac equation of relativistic quantum mechanics. Three-dimensional analogues of graphene are characterized by Dirac points or lines in momentum space, which are protected by symmetry. Here, we report a novel 3D carbon allotrope belonging to a class of topological nodal line semimetals, discovered by using an evolutionary structure search method. The new carbon phase in monoclinic CC2/m/m space group, termed mm-C8C_8, consists of five-membered rings with sp3sp^3 bonding interconnected by sp2sp^2-bonded carbon networks. Enthalpy calculations reveal that mm-C8C_8 is more favorable over recently reported topological semimetallic carbon allotropes, and the dynamical stability of mm-C8C_8 is verified by phonon spectra and molecular dynamics simulations. Simulated x-ray diffraction spectra propose that mm-C8C_8 would be one of the unidentified carbon phases observed in detonation shoot. The analysis of electronic properties indicates that mm-C8C_8 exhibits the nodal line protected by both inversion and time-reversal symmetries in the absence of spin-orbit coupling and the surface band connecting the projected nodal points. Our results may help design new carbon allotropes with exotic electronic properties.Comment: 18 pages, 5 figure

    The Effects of Puerarin on Rat Ventricular Myocytes and the Potential Mechanism

    Get PDF
    Puerarin, a known isoflavone, is commonly found as a Chinese herb medicine. It is widely used in China to treat cardiac diseases such as angina, cardiac infarction and arrhythmia. However, its cardioprotective mechanism remains unclear. In this study, puerarin significantly prolonged ventricular action potential duration (APD) with a dosage dependent manner in the micromolar range on isolated rat ventricular myocytes. However, submicromolar puerarin had no effect on resting membrane potential (RMP), action potential amplitude (APA) and maximal velocity of depolarization (Vmax) of action potential. Only above the concentration of 10 mM, puerarin exhibited more aggressive effect on action potential, and shifted RMP to the positive direction. Millimolar concentrations of puerarin significantly inhibited inward rectified K+ channels in a dosage dependent manner, and exhibited bigger effects upon Kir2.1 vs Kir2.3 in transfected HEK293 cells. As low as micromolar range concentrations of puerarin significantly inhibited Kv7.1 and IKs. These inhibitory effects may due to the direct inhibition of puerarin upon channels not via the PKA-dependent pathway. These results provided direct preclinical evidence that puerarin prolonged APD via its inhibitory effect upon Kv7.1 and IKs, contributing to a better understanding the mechanism of puerarin cardioprotection in the treatment of cardiovascular diseases

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter
    corecore