2,437 research outputs found
Negative Group Velocity from Quadrupole Resonance of Plasmonic Spheres
We study the dispersions of plasmonic bands that arise from the coupling of
electric quadrupole resonances in three dimensional photonic crystals (PCs)
consisting of plasmonic spheres. Through analytical derivation, we show that
two branches of quadrupole bands in simple cubic PCs with a small lattice
constant possess negative group velocities. Distinct from double negative media
in which the negative responses originates from the coupling of electric and
magnetic responses (P and M), the negative dispersion induced by quadrupole
resonance is an intrinsic property of quadrupole that does not require coupling
to another degree of freedom. In addition, there is no simple effective medium
description. In plasmonic systems composed of metallic nanoparticle clusters,
the coupled quadrupole resonance may be tuned to lower optical frequencies, and
the coupling strength between this quadrupole resonance and external
electromagnetic (EM) waves are in the same order of the magnetic dipole M.Comment: 21 pages, 4 figure
VLT/ISAAC H-band spectroscopy of embedded massive YSOs
We have performed intermediate resolution (R = 5000), high signal-to-noise
H-band spectroscopy of a small, initial sample of three massive embedded young
stellar objects (YSOs), using VLT/ISAAC. The sample has been selected from
sources characterised in previous literature as being likely of OB spectral
type, to be unambiguously associated with bright (H < 14) single point sources
in the 2MASS database, and to have no optical counterparts. Of the targets
observed, one object shows a ~B3 spectrum, similar to a main sequence object of
the same spectral type. A second object exhibits weak HeI and H emission,
indicating an early-type source: we detect HeII absorption, which supports a
previous indirect derivation of the spectral type as mid-O. The third object
does not show absorption lines, so no spectral type can de derived. It does,
however, exhibit a rich spectrum of strong, broad emission lines and is likely
to be surrounded by dense circumstellar material and at a very early
evolutionary stage. Our results from this very small sample are in agreement
with those of Kaper et al. (2002), who also find spectra similar to optically
visible main sequence stars, together with emission line objects representing a
very early evolutionary phase, in their much larger sample of K-band spectra.Comment: 10 pages, 14 figures, A&A (accepted
Prediction of Alzheimer's disease pathophysiology based on cortical thickness patterns
AbstractIntroductionRecent studies have shown that pathologically defined subtypes of Alzheimer's disease (AD) represent distinctive atrophy patterns and clinical characteristics. We investigated whether a cortical thickness–based clustering method can reflect such findings.MethodsA total of 77 AD subjects from the Alzheimer's Disease Neuroimaging Initiative 2 data set who underwent 3-T magnetic resonance imaging, [18F]-fluorodeoxyglucose-positron emission tomography (PET), [18F]-Florbetapir PET, and cerebrospinal fluid (CSF) tests were enrolled. After clustering based on cortical thickness, diverse imaging and biofluid biomarkers were compared between these groups.ResultsThree cortical thinning patterns were noted: medial temporal (MT; 19.5%), diffuse (55.8%), and parietal dominant (P; 24.7%) atrophy subtypes. The P subtype was the youngest and represented more glucose hypometabolism in the parietal and occipital cortices and marked amyloid-beta accumulation in most brain regions. The MT subtype revealed more glucose hypometabolism in the left hippocampus and bilateral frontal cortices and less performance in memory tests. CSF test results did not differ between the groups.DiscussionCortical thickness patterns can reflect pathophysiological and clinical changes in AD
Sjögren’s syndrome-associated microRNAs in CD14+ monocytes unveils targeted TGFβ signaling
SjS-associated miRNA expression levels are positively associated in CD14+ monocytes. Linear regression analyses were used to define associations between miRNAs in HC (circle, n = 17), SLE (triangle, n = 17), and RA (diamond, n = 18) patient groups. Cutoff values established by ROC curve analyses are indicated by dotted lines. P < 0.05 was considered statistically significant. (PDF 125 kb
Impact of picture archiving communication systems on rates of duplicate imaging: a before-after study
<p>Abstract</p> <p>Background</p> <p>Electronic health information systems, such as picture archiving communication systems (PACS), are commonly believed to reduce the need for duplicate testing. However, empirical data to support this belief are not available.</p> <p>Methods</p> <p>Before-after study using administrative claims data from the Ontario Health Insurance Plan to determine whether the introduction of PACS at 10 hospitals in the Thames Valley region of southwestern Ontario, Canada between June 2004 and December 2005 reduced the frequency of duplicate imaging examinations. The imaging modalities studied were: chest and abdominal X-ray; computed tomography of the abdomen/pelvis, head, and chest. The frequency of duplicate testing was examined at 3 different time frames: 7 days, 30 days, and 60 days after a given index test.</p> <p>Results</p> <p>Overall frequencies of duplicate imaging were: 2.7% within 7 days of an index imaging test, 6.7% within 30 days, and 9.8% within 60 days. Comparing the 12 months before and 12 months after PACS, absolute reductions in the frequency of duplicate X-rays using 7-day, 30-day, and 60-day time frames were: 0.2% (P = 0.01), 0.6% (P < 0.001), and 0.9% (P < 0.001), respectively. In contrast, there were absolute <it>increases </it>in the frequency of duplicate CT scans after PACS of 0.0% (P = 0.92), 0.5% (P = 0.01), and 0.5% (P = 0.01), respectively.</p> <p>Conclusion</p> <p>The frequency of duplicate imaging is relatively low and we did not find large reductions in duplicate imaging after the introduction of PACS. Independent evaluation of electronic medical systems should be conducted to confirm widely held beliefs of their potential benefits.</p
Discordance between Liver Biopsy and FibroScan® in Assessing Liver Fibrosis in Chronic Hepatitis B: Risk Factors and Influence of Necroinflammation
BACKGROUND: Few studies have investigated predictors of discordance between liver biopsy (LB) and liver stiffness measurement (LSM) using FibroScan®. We assessed predictors of discordance between LB and LSM in chronic hepatitis B (CHB) and investigated the effects of necroinflammatory activity. METHODS: In total, 150 patients (107 men, 43 women) were prospectively enrolled. Only LSM with ≥ 10 valid measurements was considered reliable. Liver fibrosis was evaluated using the Laennec system. LB specimens <15 mm in length were considered ineligible. Reference cutoff LSM values to determine discordance were calculated from our cohort (6.0 kPa for ≥ F2, 7.5 kPa for ≥ F3, and 9.4 kPa for F4). RESULTS: A discordance, defined as a discordance of at least two stages between LB and LSM, was identified in 21 (14.0%) patients. In multivariate analyses, fibrosis stages F3-4 and F4 showed independent negative associations with discordance (P = 0.002; hazard ratio [HR], 0.073; 95% confidence interval [CI], 0.014-0.390 for F3-4 and P = 0.014; HR, 0.067; 95% CI, 0.008-0.574 for F4). LSM values were not significantly different between maximal activity grades 1-2 and 3-4 in F1 and F2 fibrosis stages, whereas LSM values were significantly higher in maximal activity grade 3-4 than 1-2 in F3 and F4 fibrosis stage (median 8.6 vs. 11.3 kPa in F3, P = 0.049; median 11.9 vs. 19.2 kPa in F4, P = 0.009). CONCLUSION: Advanced fibrosis stage (F3-4) or cirrhosis (F4) showed a negative correlation with discordance between LB and LSM in patients with CHB, and maximal activity grade 3-4 significantly influenced LSM values in F3 and F4
The impact of advanced maternal age and parity on obstetric and perinatal outcomes in singleton gestations
Protective effect of etanercept, an inhibitor of tumor necrosis factor-α, in a rat model of retinal ischemia
Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV
A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay
channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7
TeV is presented. The data were collected at the LHC, with the CMS detector,
and correspond to an integrated luminosity of 4.6 inverse femtobarns. No
significant excess is observed above the background expectation, and upper
limits are set on the Higgs boson production cross section. The presence of the
standard model Higgs boson with a mass in the 270-440 GeV range is excluded at
95% confidence level.Comment: Submitted to JHE
Search for Neutral Higgs Bosons in Events with Multiple Bottom Quarks at the Tevatron
The combination of searches performed by the CDF and D0 collaborations at the
Fermilab Tevatron Collider for neutral Higgs bosons produced in association
with b quarks is reported. The data, corresponding to 2.6 fb-1 of integrated
luminosity at CDF and 5.2 fb-1 at D0, have been collected in final states
containing three or more b jets. Upper limits are set on the cross section
multiplied by the branching ratio varying between 44 pb and 0.7 pb in the Higgs
boson mass range 90 to 300 GeV, assuming production of a narrow scalar boson.
Significant enhancements to the production of Higgs bosons can be found in
theories beyond the standard model, for example in supersymmetry. The results
are interpreted as upper limits in the parameter space of the minimal
supersymmetric standard model in a benchmark scenario favoring this decay mode.Comment: 10 pages, 2 figure
- …