812 research outputs found

    Assessment of median nerve mobility by ultrasound dynamic imaging in carpal tunnel syndrome diagnosis

    Get PDF
    2013 Joint UffC, EFTF and PFM SymposiumCarpal tunnel syndrome (CTS) is a common entrapment neuropathy. Nerve conduction studies (NCS) have been used as a standard for CTS diagnosis. Complementing NCS, ultrasound imaging provides anatomic information on pathologic changes of the median nerve, such as the reduced median nerve mobility. Motion of median nerve is dependent on mechanical characteristics, and body movements. The purpose of this study was therefore to measure transverse sliding patterns of the median nerve during fingers flexion and extension in ultrasound B-mode images for distinguishing healthy from CTS subjects, and to investigate any correlation between NCS severity and median nerve motion. Transverse ultrasound images were acquired from 19 normal, 15 mild, and 10 severe CTS subjects confirmed by NCS. In two-second acquisition, their fingers were initially in natural position; the median nerve was then moved toward the ulnar side and radius side in fingers flexion and extension, respectively. The displacements of the median nerve were calculated by the multilevel block-matching pyramid algorithm and averaged. All the average displacements at different acquisition times were then accumulated to obtain cumulative displacements, which were curve-fitted by polynomial function. To differentiate the normal from CTS cases, the R-squared, curvature, and amplitude of the fitted curves were computed, to evaluate the goodness, variation, and maximum value of the fit, respectively. Compared to the CTS patients, the normal subjects had higher R-square, curvature, and amplitude estimates. The three parameters were then inputted to a fuzzy c-means algorithm to classify normal cases and CTS ones. The diagnostic efficiency had an accuracy of 93.2%, a specificity of 100%, and a sensitivity of 88%. Further study includes measuring mechanical strain and stress at different neural sites to provide elasticity of the median nerve. Š 2013 IEEE.published_or_final_versio

    Biphasic pulses enhance bleomycin efficacy in a spontaneous canine genital tumor model of chemoresistance: Sticker sarcoma

    Get PDF
    Sticker's sarcoma (also known as transmissible venereal tumor) is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT), treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 Îźs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψ′→π+π−J/ψ(J/ψ→γppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ′\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=1861−13+6(stat)−26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics

    Sitting and standing performance in a total population of children with cerebral palsy: a cross-sectional study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knowledge of sitting and standing performance in a total population of children with cerebral palsy (CP) is of interest for health care planning and for prediction of future ability in the individual child. In 1994, a register and a health care programme for children with CP in southern Sweden was initiated. In the programme information on how the child usually sits, stands, stands up and sits down, together with use of support or assistive devices, is recorded annually.</p> <p>Methods</p> <p>A cross-sectional study was performed, analysing the most recent report of all children with CP born 1990-2005 and living in southern Sweden during 2008. All 562 children (326 boys, 236 girls) aged 3-18 years were included in the study. The degree of independence, use of support or assistive devices to sit, stand, stand up and sit down was analysed in relation to the Gross Motor Function Classification System (GMFCS), CP subtype and age.</p> <p>Result</p> <p>A majority of the children used standard chairs (57%), could stand independently (62%) and could stand up (62%) and sit down (63%) without external support. Adaptive seating was used by 42%, external support to stand was used by 31%, to stand up by 19%, and to sit down by 18%. The use of adaptive seating and assistive devices increased with GMFCS levels (p < 0.001) and there was a difference between CP subtypes (p < 0.001). The use of support was more frequent in preschool children aged 3-6 (p < 0.001).</p> <p>Conclusion</p> <p>About 60% of children with CP, aged 3-18, use standard chairs, stand, stand up, and sit down without external support. Adding those using adaptive seating and external support, 99% of the children could sit, 96% could stand and 81% could stand up from a sitting position and 81% could sit down from a standing position. The GMFCS classification system is a good predictor of sitting and standing performance.</p

    The effect of graphene oxide (GO) nanoparticles on the processing of epoxy/glass fiber composites using resin infusion

    Get PDF
    In this paper, the effects of graphene oxide (GO) nanoparticles on glass fiber composite processing by incorporating them into epoxy resin were investigated. GO was synthesized from graphite powder and was mixed with epoxy resin. Three different GO contents of 0.05, 0.1, and 0.2 wt% were used. Epoxy/GO samples were tested for rheology and cure kinetics to evaluate the effects of GO content on important resin infusion processing parameters. The results show that adding GO to neat epoxy resin increased the viscosity and affected the resin cure reaction by reducing the resin gel time. After that, glass fiber composites were prepared using the resin infusion process. Samples with 0.2 wt% GO result in very slow resin infiltration time with premature resin gelation. A 30 % increase in flexural strength and a 21 % increase in flexural modulus are manifested by adding GO as the secondary reinforcement to glass fiber composites

    Effects of Vacuum Annealing on the Conduction Characteristics of ZnO Nanosheets

    Get PDF
    This paper is open acess and available in full at http://www.nanoscalereslett.com/content/10/1/368 .ZnO nanosheets are a relatively new form of nanostructure and have demonstrated potential as gas-sensing devices and dye sensitised solar cells. For integration into other devices, and when used as gas sensors, the nanosheets are often heated. Here we study the effect of vacuum annealing on the electrical transport properties of ZnO nanosheets in order to understand the role of heating in device fabrication. A low cost, mass production method has been used for synthesis and characterisation is achieved using scanning electron microscopy (SEM), photoluminescence (PL), auger electron spectroscopy (AES) and nanoscale two-point probe. Before annealing, the measured nanosheet resistance displayed a non-linear increase with probe separation, attributed to surface contamination. Annealing to 300 °C removed this contamination giving a resistance drop, linear probe spacing dependence, increased grain size and a reduction in the number of n-type defects. Further annealing to 500 °C caused the n-type defect concentration to reduce further with a corresponding increase in nanosheet resistance not compensated by any further sintering. At 700 °C, the nanosheets partially disintegrated and the resistance increased and became less linear with probe separation. These effects need to be taken into account when using ZnO nanosheets in devices that require an annealing stage during fabrication or heating during use

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …
    corecore