740 research outputs found
Shape variation in modern human upper premolars
Morphological variation in modern human dentition is still an open field of study. The understanding of dental shape and metrics is relevant for the advancement of human biology and evolution and is thus of interest in the fields of dental anthropology, as well as human anatomy and medicine. Of concern is also the variation of the inner aspects of the crown which can be investigated using the tools and methods of virtual anthropology. In this study, we explored inter- and intra-population morphometric variation of modern humans’ upper third and fourth premolars (P3s and P4s, respectively) considering both the inner and outer aspects of the crown, and discrete traits. We worked by means of geometric morphometrics on 3D image data from a geographically balanced sample of human populations from five continents, to analyse the shape of the dentinal crown, and the crown outline in 78 P3s and 76 P4s from 85 individuals. For the study of dental traits, we referred to the Arizona State University Dental Anthropology System integrated with more recent classification systems. The 3D shape variation of upper premolar crowns varied between short and mesio-distally broad, and tall and mesio-distally narrow. The observed shape variation was independent from the geographical origin of the populations, and resulted in extensive overlap. We noted a high pairwise correlation (r1 = 0.83) between upper P3s and P4s. We did not find any significant geographic differences in the analysed non-metric traits. Our outcomes thus suggest that geographical provenance does not play a determinant role in the shaping of the dental crown, whose genesis is under strict genetic control
Vacuum-stimulated cooling of single atoms in three dimensions
Taming quantum dynamical processes is the key to novel applications of
quantum physics, e.g. in quantum information science. The control of
light-matter interactions at the single-atom and single-photon level can be
achieved in cavity quantum electrodynamics, in particular in the regime of
strong coupling where atom and cavity form a single entity. In the optical
domain, this requires permanent trapping and cooling of an atom in a
micro-cavity. We have now realized three-dimensional cavity cooling and
trapping for an orthogonal arrangement of cooling laser, trap laser and cavity
vacuum. This leads to average single-atom trapping times exceeding 15 seconds,
unprecedented for a strongly coupled atom under permanent observation.Comment: 4 pages, 4 figure
Metal enrichment processes
There are many processes that can transport gas from the galaxies to their
environment and enrich the environment in this way with metals. These metal
enrichment processes have a large influence on the evolution of both the
galaxies and their environment. Various processes can contribute to the gas
transfer: ram-pressure stripping, galactic winds, AGN outflows, galaxy-galaxy
interactions and others. We review their observational evidence, corresponding
simulations, their efficiencies, and their time scales as far as they are known
to date. It seems that all processes can contribute to the enrichment. There is
not a single process that always dominates the enrichment, because the
efficiencies of the processes vary strongly with galaxy and environmental
properties.Comment: 18 pages, 8 figures, accepted for publication in Space Science
Reviews, special issue "Clusters of galaxies: beyond the thermal view",
Editor J.S. Kaastra, Chapter 17; work done by an international team at the
International Space Science Institute (ISSI), Bern, organised by J.S.
Kaastra, A.M. Bykov, S. Schindler & J.A.M. Bleeke
Gravity Recovery and Interior Laboratory (GRAIL): Extended Mission and End-Game Status
The Gravity Recovery and Interior Laboratory (GRAIL) [1], NASA s eleventh Discovery mission, successfully executed its Primary Mission (PM) in lunar orbit between March 1, 2012 and May 29, 2012. GRAIL s Extended Mission (XM) initiated on August 30, 2012 and was successfully completed on December 14, 2012. The XM provided an additional three months of gravity mapping at half the altitude (23 km) of the PM (55 km), and is providing higherresolution gravity models that are being used to map the upper crust of the Moon in unprecedented detail
Charge separation relative to the reaction plane in Pb-Pb collisions at TeV
Measurements of charge dependent azimuthal correlations with the ALICE
detector at the LHC are reported for Pb-Pb collisions at TeV. Two- and three-particle charge-dependent azimuthal correlations in
the pseudo-rapidity range are presented as a function of the
collision centrality, particle separation in pseudo-rapidity, and transverse
momentum. A clear signal compatible with a charge-dependent separation relative
to the reaction plane is observed, which shows little or no collision energy
dependence when compared to measurements at RHIC energies. This provides a new
insight for understanding the nature of the charge dependent azimuthal
correlations observed at RHIC and LHC energies.Comment: 12 pages, 3 captioned figures, authors from page 2 to 6, published
version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/286
A note on comonotonicity and positivity of the control components of decoupled quadratic FBSDE
In this small note we are concerned with the solution of Forward-Backward
Stochastic Differential Equations (FBSDE) with drivers that grow quadratically
in the control component (quadratic growth FBSDE or qgFBSDE). The main theorem
is a comparison result that allows comparing componentwise the signs of the
control processes of two different qgFBSDE. As a byproduct one obtains
conditions that allow establishing the positivity of the control process.Comment: accepted for publicatio
Transverse sphericity of primary charged particles in minimum bias proton-proton collisions at , 2.76 and 7 TeV
Measurements of the sphericity of primary charged particles in minimum bias
proton--proton collisions at , 2.76 and 7 TeV with the ALICE
detector at the LHC are presented. The observable is linearized to be collinear
safe and is measured in the plane perpendicular to the beam direction using
primary charged tracks with GeV/c in . The
mean sphericity as a function of the charged particle multiplicity at
mid-rapidity () is reported for events with different
scales ("soft" and "hard") defined by the transverse momentum of the leading
particle. In addition, the mean charged particle transverse momentum versus
multiplicity is presented for the different event classes, and the sphericity
distributions in bins of multiplicity are presented. The data are compared with
calculations of standard Monte Carlo event generators. The transverse
sphericity is found to grow with multiplicity at all collision energies, with a
steeper rise at low , whereas the event generators show the
opposite tendency. The combined study of the sphericity and the mean with multiplicity indicates that most of the tested event generators
produce events with higher multiplicity by generating more back-to-back jets
resulting in decreased sphericity (and isotropy). The PYTHIA6 generator with
tune PERUGIA-2011 exhibits a noticeable improvement in describing the data,
compared to the other tested generators.Comment: 21 pages, 9 captioned figures, 3 tables, authors from page 16,
published version, figures from
http://aliceinfo.cern.ch/ArtSubmission/node/308
Preliminary Results on Lunar Interior Properties from the GRAIL Mission
The Gravity Recovery and Interior Laboratory (GRAIL) mission has provided lunar gravity with unprecedented accuracy and resolution. GRAIL has produced a high-resolution map of the lunar gravity field while also determining tidal response. We present the latest gravity field solution and its preliminary implications for the Moon's interior structure, exploring properties such as the mean density, moment of inertia of the solid Moon, and tidal potential Love number k2. Lunar structure includes a thin crust, a deep mantle, a fluid core, and a suspected solid inner core. An accurate Love number mainly improves knowledge of the fluid core and deep mantle. In the future GRAIL will search for evidence of tidal dissipation and a solid inner core
The CPLEAR Electromagnetic Calorimeter
A large-acceptance lead/gas sampling electromagnetic calorimeter (ECAL) was constructed for the CPLEAR experiment to detect photons from decays of s with momentum MeV. The main purpose of the ECAL is to determine the decay vertex of neutral-kaon decays \ko \rightarrow \pi^0\pi^0 \rightarrow 4 \gamma and \ko \rightarrow \pi^0\pi^0\pi^0 \rightarrow 6 \gamma. This requires a position-sensitive photon detector with high spatial granularity in -, -, and -coordinates. The ECAL --- a barrel without end-caps located inside a magnetic field of 0.44 T --- consists of 18 identical concentric layers. Each layer of radiation length (X) contains a converter plate followed by small cross-section high-gain tubes of 2640 mm active length which are sandwiched by passive pick-up strip plates. The ECAL, with a total of X, has an energy resolution of and a position resolution of 4.5 mm for the shower foot. The shower topology allows separation of electrons from pions. The design, construction, read-out electronics, and performance of the detector are described
Multi-particle azimuthal correlations in p-Pb and Pb-Pb collisions at the CERN Large Hadron Collider
Measurements of multi-particle azimuthal correlations (cumulants) for charged
particles in p-Pb and Pb-Pb collisions are presented. They help address the
question of whether there is evidence for global, flow-like, azimuthal
correlations in the p-Pb system. Comparisons are made to measurements from the
larger Pb-Pb system, where such evidence is established. In particular, the
second harmonic two-particle cumulants are found to decrease with multiplicity,
characteristic of a dominance of few-particle correlations in p-Pb collisions.
However, when a gap is placed to suppress such correlations,
the two-particle cumulants begin to rise at high-multiplicity, indicating the
presence of global azimuthal correlations. The Pb-Pb values are higher than the
p-Pb values at similar multiplicities. In both systems, the second harmonic
four-particle cumulants exhibit a transition from positive to negative values
when the multiplicity increases. The negative values allow for a measurement of
to be made, which is found to be higher in Pb-Pb collisions at
similar multiplicities. The second harmonic six-particle cumulants are also
found to be higher in Pb-Pb collisions. In Pb-Pb collisions, we generally find
which is indicative of a Bessel-Gaussian
function for the distribution. For very high-multiplicity Pb-Pb
collisions, we observe that the four- and six-particle cumulants become
consistent with 0. Finally, third harmonic two-particle cumulants in p-Pb and
Pb-Pb are measured. These are found to be similar for overlapping
multiplicities, when a gap is placed.Comment: 25 pages, 11 captioned figures, 3 tables, authors from page 20,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/87
- …