1,221 research outputs found

    In situ Probe Microphone Measurement for Testing the Direct Acoustical Cochlear Stimulator

    Get PDF
    Hypothesis: Acoustical measurements can be used for functional control of a direct acoustic cochlear stimulator (DACS).Background: The DACS is a recently released active hearing implant that works on the principle of a conventional piston prosthesis driven by the rod of an electromagnetic actuator. An inherent part of the DACS actuator is a thin titanium diaphragm that allows for movement of the stimulation rod while hermetically sealing the housing. In addition to mechanical stimulation, the actuator emits sound into the mastoid cavity because of the motion of the diaphragm.Methods: We investigated the use of the sound emission of a DACS for intra-operative testing. We measured sound emission in the external auditory canal (PEAC) and velocity of the actuators stimulation rod (Vact) in five implanted ears of whole-head specimens. We tested the influence various positions of the loudspeaker and a probe microphone on PEAC and simulated implant malfunction in one example.Results: Sound emission of the DACS with a signal-to-noise ratio >10 dB was observed between 0.5 and 5 kHz. Simulated implant misplacement or malfunction could be detected by the absence or shift in the characteristic resonance frequency of the actuator. PEAC changed by <6 dB for variations of the microphone and loudspeaker position.Conclusion: Our data support the feasibility of acoustical measurements for in situ testing of the DACS implant in the mastoid cavity as well as for post-operative monitoring of actuator function

    Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality

    Get PDF
    Introduction: The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Methods: Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Results: Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = −0.94/−0.88) and was highest at 80kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80kV. However, image quality improvement was most relevant for low-dose scans. Conclusions: Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocol

    Effect of freezing and embalming of human cadaveric whole head specimens on bone conduction.

    Get PDF
    BACKGROUND AND AIMS Conserved specimens do not decay and therefore permit long-term experiments thereby overcoming limited access to fresh (frozen) temporal bones for studies on middle ear mechanics. We used a Thiel conservation method which is mainly based on a watery solution of salts. In contrast to pure Formalin, Thiel conservation aims to preserve the mechanical proprieties of human tissue. The aim of this study is to examine the effect of Thiel conservation on bone conduction in the same specimen before and after conservation. METHODS Nine ears of five defrosted whole heads were stimulated with a direct, electrically driven, bone anchored hearing system (Baha, Baha SuperPower). The motion produced by bone conduction stimulation was measured with a single point laser Doppler vibrometer (LDV) at the promontory, the ossicular chain, and the round window through a posterior tympanotomy. After the initial experiments, the entire whole heads were placed in Thiel solution. In order to enable direct comparison between fresh frozen and Thiel specimens, our Thiel conservation did not include intravascular and intrathecal perfusion. The measurements were repeated 3 and 12 months later. To determine the effect of freezing, defrosting, and embalming on the whole heads, CT scans were performed at different stages of the experimental procedure. Additionally, three extracted temporal bones were stimulated a Baha, motion of the promontory measured by LDV and embalmed in Thiel solution to investigate the direct impact of Thiel solution on the bone. RESULTS The averaged magnitude of motion on the promontory increased in whole head specimens by a mean of 10.3 dB after 3 months of Thiel embalming and stayed stable after 12 months. A similar effect was observed for motion at the tympanic membrane (+7.2 dB), the stapes (+9.5 dB), and the round window (+4.0 dB). In contrast to the whole head specimens, the motion of the extracted temporal bones did not change after 3 months of Thiel embalming (-0.04 dB in average). CT scans of the whole heads after conservation showed a notable brain volume loss mostly >50% as well as a remarkable change in the consistency and structure of the brain. Partial changes could already be observed before the Thiel embalming but after 1-2 days of defrosting. In an additional experiment, a substitution of brain mass and weight by Thiel fluid did not lead to new deterioration in sound transmission. In contrast, a frozen (non-defrosted) whole head showed a distinctively reduced magnitude of promontory motion before defrosting. DISCUSSION For our setup, the vibration of the ear due to bone conduction in the same whole head specimens significantly increased after Thiel conservation. Such an increase was not observed in extracted temporal bone specimens. Due to brain changes in the CT scans, we investigated the consequences of the brain volume changes and structure loss on the frozen brain before defrosting. The loss of brain volume alone could not explain the increase of ear vibrations, as we did not observe a difference when the volume was replaced with Thiel fluid. However, freezing and defrosting of the entire brain seems to have a major influence. Beside the destructive effect of freezing on the brain, the modified conservation method without perfusion changed the brain structure. In conclusion, bone conduction in whole heads depends on the physical condition of the brain, rather than on the conservation

    A bone-thickness map as a guide for bone-anchored port implantation surgery in the temporal bone

    Get PDF
    The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant’s location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map (n = 10) with conventional surgery without assistance (n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and OPEN ACCESS Materials 2013, 6 5292 suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient’s safety during BAP surgery in the temporal bone

    Differential cross section measurements for the production of a W boson in association with jets in proton–proton collisions at √s = 7 TeV

    Get PDF
    Measurements are reported of differential cross sections for the production of a W boson, which decays into a muon and a neutrino, in association with jets, as a function of several variables, including the transverse momenta (pT) and pseudorapidities of the four leading jets, the scalar sum of jet transverse momenta (HT), and the difference in azimuthal angle between the directions of each jet and the muon. The data sample of pp collisions at a centre-of-mass energy of 7 TeV was collected with the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 fb[superscript −1]. The measured cross sections are compared to predictions from Monte Carlo generators, MadGraph + pythia and sherpa, and to next-to-leading-order calculations from BlackHat + sherpa. The differential cross sections are found to be in agreement with the predictions, apart from the pT distributions of the leading jets at high pT values, the distributions of the HT at high-HT and low jet multiplicity, and the distribution of the difference in azimuthal angle between the leading jet and the muon at low values.United States. Dept. of EnergyNational Science Foundation (U.S.)Alfred P. Sloan Foundatio

    Penilaian Kinerja Keuangan Koperasi di Kabupaten Pelalawan

    Full text link
    This paper describe development and financial performance of cooperative in District Pelalawan among 2007 - 2008. Studies on primary and secondary cooperative in 12 sub-districts. Method in this stady use performance measuring of productivity, efficiency, growth, liquidity, and solvability of cooperative. Productivity of cooperative in Pelalawan was highly but efficiency still low. Profit and income were highly, even liquidity of cooperative very high, and solvability was good

    Optimasi Portofolio Resiko Menggunakan Model Markowitz MVO Dikaitkan dengan Keterbatasan Manusia dalam Memprediksi Masa Depan dalam Perspektif Al-Qur`an

    Full text link
    Risk portfolio on modern finance has become increasingly technical, requiring the use of sophisticated mathematical tools in both research and practice. Since companies cannot insure themselves completely against risk, as human incompetence in predicting the future precisely that written in Al-Quran surah Luqman verse 34, they have to manage it to yield an optimal portfolio. The objective here is to minimize the variance among all portfolios, or alternatively, to maximize expected return among all portfolios that has at least a certain expected return. Furthermore, this study focuses on optimizing risk portfolio so called Markowitz MVO (Mean-Variance Optimization). Some theoretical frameworks for analysis are arithmetic mean, geometric mean, variance, covariance, linear programming, and quadratic programming. Moreover, finding a minimum variance portfolio produces a convex quadratic programming, that is minimizing the objective function ðð¥with constraintsð ð 𥠥 ðandð´ð¥ = ð. The outcome of this research is the solution of optimal risk portofolio in some investments that could be finished smoothly using MATLAB R2007b software together with its graphic analysis
    corecore