35 research outputs found

    An Implantable ENG Detector with In-System Velocity Selective Recording (VSR) Capability

    Get PDF
    Detection and classification of electroneurogram (ENG) signals in the peripheral nervous system can be achieved by velocity selective recording (VSR) using multi-electrode arrays. This paper describes an implantable VSR-based ENG recording system representing a significant development in the field since it is the first system of its type that can record naturally-evoked ENG and be interfaced wirelessly using a low data rate trans-cutaneous link. The system consists of two CMOS ASICs one of which is placed close to the multielectrode cuff array (MEC) while the other is mounted close to the wireless link. The digital ASIC provides the signal processing required to detect selectively ENG signals based on velocity. The design makes use of an original architecture that is suitable for implantation and reduces the required data rate for transmission to units placed outside the body. Complete measured electrical data from samples of the ASICs are presented that show that the system has the capability to record signals of amplitude as low as 0.5 μV, which is adequate for the recording of naturally evoked ENG. In addition, measurements of electrically evoked ENG from the explanted sciatic nerves of Xenopus Laevis frogs are presented

    A summary of the theory of velocity selective neural recording

    Get PDF
    This paper describes improvements to the technique of velocity selective recording (VSR) in which multiple neural signals are matched and summed to identify excited axon populations in terms of velocity. This form of recording has been termed intrinsic velocity selective recording (IVSR). The signals are acquired using a multi-electrode cuff (MEC) which is now available as a component for use in implantable neuroprostheses. The improvements outlined in the paper involve the use of bandpass filters at the output of the system which allows a higher level of selectivity to be obtained than is possible using IVSR. © 2011 IEEE

    An Implantable ENG Detector with In-System Velocity Selective Recording (VSR) Capability

    Get PDF
    Detection and classification of electroneurogram (ENG) signals in the peripheral nervous system can be achieved by velocity selective recording (VSR) using multi-electrode arrays. This paper describes an implantable VSR-based ENG recording system representing a significant development in the field since it is the first system of its type that can record naturally evoked ENG and be interfaced wirelessly using a low data rate transcutaneous link. The system consists of two CMOS ASICs one of which is placed close to the multi-electrode cuff array (MEC), whilst the other is mounted close to the wireless link. The digital ASIC provides the signal processing required to detect selectively ENG signals based on velocity. The design makes use of an original architecture that is suitable for implantation and reduces the required data rate for transmission to units placed outside the body. Complete measured electrical data from samples of the ASICs are presented that show that the system has the capability to record signals of amplitude as low as 0.5 μV, which is adequate for the recording of naturally evoked ENG. In addition, measurements of electrically evoked ENG from the explanted sciatic nerves of Xenopus Laevis frogs are presented

    Organic electrode coatings for next-generation neural interfaces

    Get PDF
    Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however, several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes
    corecore