2,659 research outputs found
Online Pattern Recognition for the ALICE High Level Trigger
The ALICE High Level Trigger has to process data online, in order to select
interesting (sub)events, or to compress data efficiently by modeling
techniques.Focusing on the main data source, the Time Projection Chamber (TPC),
we present two pattern recognition methods under investigation: a sequential
approach "cluster finder" and "track follower") and an iterative approach
("track candidate finder" and "cluster deconvoluter"). We show, that the former
is suited for pp and low multiplicity PbPb collisions, whereas the latter might
be applicable for high multiplicity PbPb collisions, if it turns out, that more
than 8000 charged particles would have to be reconstructed inside the TPC.
Based on the developed tracking schemes we show, that using modeling techniques
a compression factor of around 10 might be achievableComment: Realtime Conference 2003, Montreal, Canada to be published in IEEE
Transactions on Nuclear Science (TNS), 6 pages, 8 figure
Configurable Electronics with Low Noise and 14-bit Dynamic Range for Photodiode-based Photon Detectors
We describe the principles and measured performance characteristics of custom configurable 32-channel shaper/digitizer Front End Electronics (FEE) cards with 14-bit dynamic range for use with gain-adjustable photon detectors. The electronics has been designed for the PHOS calorimeter of ALICE with avalanche photodiode (APD) readout operated at -25 C ambient temperature and a signal shaping time of . The electronics has also been adopted by the EMCal detector of ALICE with the same APD readout, but operated at an ambient temperature of +20 C and with a shaping time of 100ns. The CR-RC2 signal shapers on the FEE cards are implemented in discrete logic on a 10-layer board with two shaper sections for each input channel. The two shaper sections with gain ratio of 16:1 are digitized by 10-bit ADCs and provide an effective dynamic range of 14 bits. Gain adjustment for each individual APD is available through 32 bias voltage control registers of 10-bit range. The fixed gains and shaping times of the pole-zero compensated shapers are defined prior to FEE production by the values of a few R and C components. For trigger purposes, "fast OR" outputs with 12-bit dynamic range are available. FPGA based slave logic, combined with a USB processor supports a variety of remote control and monitoring features, including APD gain calibration. The measurements presented here for APDs at -25 C ambient temperature and shaping time achieve an average RMS noise level of 0.25 ADC counts or 290 electrons.The linearity over the dynamic range is better than 1%, as is the uniformity of shaping time and gain over 32 channels. Due to the excellent correspondence of the output pulse shape with offline fit, a differential timing resolution of less than 1.5 ns between channels has been achieved at ca. 2 GeV, i.e. at 1.5% of the dynamic range of PHOS
Photodiode read-out of the ALICE photon spectrometer crystals
Proposal of abstract for LEB99, Snowmass, Colorado, 20-24 September 1999The PHOton Spectrometer of the ALICE experiment is an electromagnetic calorimeter of high granularity consisting of 17280 lead-tungstate (PWO) crystals of dimensions 22x22x180 mm3, read out by large-area PIN-diodes with very low-noise front-end electronics. The crystal assembly is operated at -25C to increase the PWO light yield. A 16.1x17.1 mm2 photodiode, optimized for the PWO emissio spectrum at 400-500 nm, has been developed. The 20x20 mm2 preamplifier PCB is attached to the back side of the diode ceramic frame. The charge sensitive preamplifier is built in discrete logic with two input JFETs for optimum matching with the ~150pF PIN-diode. A prototype shaper has been designed and built in discrete logic. For a detector matrix of 64 units the measured ENCs are between 450-550e at -25C. Beam tests demonstrate that the required energy resolution is reached.Summary:The PHOton Spectrometer of the ALICE experiment is an electromagnetic calorimeter of high granularity consisting of 17280 lead-tungstate (PWO) crystals of dimensions 22x22x180 mm3, coupled to large-area PIN-diodes with matching low-noise preamplifiers. PHOS is optimized for measuring photons, pi0s and eta mesons in the momentum ranges 0.5-10, 1-10 and 2-10 GeV/c, respectively, and is designed for the expected large number of particles that will be produced in central Pb-Pb collisions. Lead tungstate (PWO) is a fast scintillating crystal with a rather complex emission spectrum, consisting of two components: a blue component peaking at 420 nm and a green component peaking at 480-520 nm. The light yield of PWO at room temperature is low compared with other heavy scintillating crystals, for instance BGO. However, the yield depends strongly on the temperature with a coefficient of ~-2 degree. At the selected operating temperature of -25C the yield is about a factor of 3 higher compared to room temperature. Still, in order to reach the required energy resolution for a PHOS channel, an ENC noise of less than 600e for the PIN-diode-preamplifier-shaper stage is required. This is a very low value taking into account the high capacitance of 150-200 pF of the large area PIN-diodes. In collaboration with the PHOS project, the company AME (Horten, Norway) has designed and produced a PIN-photodiode optimized for the cross-section and spectral responsivity of the PHOS PWO crystal. The photodiode has an active area of 17.1x16.1 mm2 and is fabricated on n-type silicon material of thickness 280 um. The wafer specific resistivity is between 3000 and 6000 ohm-cm, which corresponds to a depletion voltage of 70V. The photodiode response is optimized for the spectral region 400-500 nm in order to match the PWO emission spectrum. The PIN-diode is mounted on a ceramic substrate 0.65 mm thick. On this substrate the diode is surrounded by a ceramic frame. The preamplifier PCB of dimension 20x20 mm2 is attached to the back side of the frame. The PIN-diode and bondings to ground and preamplifier input are protected by an optically transparent epoxy layer. The front side of the PIN-diode is glued onto the endface of the PWO crystal with optically transparent glue (Melt-Mount Quick-Stick, Cargille Laboratories, USA). Each crystal is wrapped in White Tyvek to ensure maximum light collection efficiency and optical insulation between the crystals. The PHOS detector consists of four independent modules, each with 4320 channels. The crystal assembly with the photo detectors are operated at -25 +/- 0.3C. The power dissipation per module is ~1 kW. The charge sensitive preamplifier is an operational amplifier built in discrete logic and with two input JFETs (BF861A). Using two JFETs in parallel gives the lowest noise for detector capacitance >100 pF. A prototype shaper, comprising three amplification stages, has been designed and built in discrete logic. For a PIN-diode with capacitance ~150 pF and a leakage current <1 nA under cooling, calculations give optimum time differentiation and integration constants around 3 microsec. For a detector matrix of 64 units the measured ENCs are between 450-550 e at -25C. Beam tests of this matrix show that the required energy resolution for the PHOS is reached
Real-time TPC Analysis with the ALICE High-Level Trigger
The ALICE High-Level Trigger processes data online, to either select
interesting (sub-) events, or to compress data efficiently by modeling
techniques.
Focusing on the main data source, the Time Projection Chamber, the
architecure of the system and the current state of the tracking and compression
methods are outlined.Comment: 6 pages, 5 figures, to be published in NIM
The ALICE DAQ: Current Status and Future Challenges
Proposal of abstract for CHEP2000The ALICE DAQ system has been designed to support an aggregate eventr building bandwidth of up to 2.5 GByte/s and a storage capability o fup to 1.25 GByte/s to mass storage.A general framework called the ALICE Data Acquisition Test Environment (DATE) system has been developed as a basis for prototyping the components of the DAQ. DATE supports a wide spectrum of configurations from simple systems to more complex systems with multiple detectors and multiple event builders.Prototypes of several key components of the ALICE DAQ have been developed and integrated with the DATE system, such as the ALICE Detector Data Link, the online data monitoring from ROOT and the interface to the Mass Storage systems. Combined tests of several of these components are pursued during the ALICE Data Challenges.The architecture of the ALICE DAQ system will be presented together with the current status of the different prototypes. The recent addition of a Transition Radiation Detector (TRD) to ALICE has required a revision of the requirements and the architecture of the DAQ. This will allow a higher level of data selection. These new opportunities and implementation challenges will also be presented
Charge separation relative to the reaction plane in Pb-Pb collisions at TeV
Measurements of charge dependent azimuthal correlations with the ALICE
detector at the LHC are reported for Pb-Pb collisions at TeV. Two- and three-particle charge-dependent azimuthal correlations in
the pseudo-rapidity range are presented as a function of the
collision centrality, particle separation in pseudo-rapidity, and transverse
momentum. A clear signal compatible with a charge-dependent separation relative
to the reaction plane is observed, which shows little or no collision energy
dependence when compared to measurements at RHIC energies. This provides a new
insight for understanding the nature of the charge dependent azimuthal
correlations observed at RHIC and LHC energies.Comment: 12 pages, 3 captioned figures, authors from page 2 to 6, published
version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/286
Multiplicity dependence of jet-like two-particle correlations in p-Pb collisions at = 5.02 TeV
Two-particle angular correlations between unidentified charged trigger and
associated particles are measured by the ALICE detector in p-Pb collisions at a
nucleon-nucleon centre-of-mass energy of 5.02 TeV. The transverse-momentum
range 0.7 5.0 GeV/ is examined,
to include correlations induced by jets originating from low
momen\-tum-transfer scatterings (minijets). The correlations expressed as
associated yield per trigger particle are obtained in the pseudorapidity range
. The near-side long-range pseudorapidity correlations observed in
high-multiplicity p-Pb collisions are subtracted from both near-side
short-range and away-side correlations in order to remove the non-jet-like
components. The yields in the jet-like peaks are found to be invariant with
event multiplicity with the exception of events with low multiplicity. This
invariance is consistent with the particles being produced via the incoherent
fragmentation of multiple parton--parton scatterings, while the yield related
to the previously observed ridge structures is not jet-related. The number of
uncorrelated sources of particle production is found to increase linearly with
multiplicity, suggesting no saturation of the number of multi-parton
interactions even in the highest multiplicity p-Pb collisions. Further, the
number scales in the intermediate multiplicity region with the number of binary
nucleon-nucleon collisions estimated with a Glauber Monte-Carlo simulation.Comment: 23 pages, 6 captioned figures, 1 table, authors from page 17,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/161
Multi-particle azimuthal correlations in p-Pb and Pb-Pb collisions at the CERN Large Hadron Collider
Measurements of multi-particle azimuthal correlations (cumulants) for charged
particles in p-Pb and Pb-Pb collisions are presented. They help address the
question of whether there is evidence for global, flow-like, azimuthal
correlations in the p-Pb system. Comparisons are made to measurements from the
larger Pb-Pb system, where such evidence is established. In particular, the
second harmonic two-particle cumulants are found to decrease with multiplicity,
characteristic of a dominance of few-particle correlations in p-Pb collisions.
However, when a gap is placed to suppress such correlations,
the two-particle cumulants begin to rise at high-multiplicity, indicating the
presence of global azimuthal correlations. The Pb-Pb values are higher than the
p-Pb values at similar multiplicities. In both systems, the second harmonic
four-particle cumulants exhibit a transition from positive to negative values
when the multiplicity increases. The negative values allow for a measurement of
to be made, which is found to be higher in Pb-Pb collisions at
similar multiplicities. The second harmonic six-particle cumulants are also
found to be higher in Pb-Pb collisions. In Pb-Pb collisions, we generally find
which is indicative of a Bessel-Gaussian
function for the distribution. For very high-multiplicity Pb-Pb
collisions, we observe that the four- and six-particle cumulants become
consistent with 0. Finally, third harmonic two-particle cumulants in p-Pb and
Pb-Pb are measured. These are found to be similar for overlapping
multiplicities, when a gap is placed.Comment: 25 pages, 11 captioned figures, 3 tables, authors from page 20,
published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/87
- âŠ