26 research outputs found

    Scantlings for small wooden fishing vessels

    Get PDF
    Studies are carried out to find a suitable basis of specifying scantlings for wooden fishing vessels for India, especially for the range 30' to 50' length overall. Equations of the type y=a (where 'y' is scantling in inches, N is cubic numeral in ft³ and 'a', 'b' are constants) are fitted to the scantling tables (applicable to vessels 50’ and above) available from USA, Newfoundland, Denmark, France and Scotland and they are found to represent the regulations accurately. These lines are corrected for standard frame and beam spacing and molded/sided dimensions to bring them on a common basis for comparison and minimum scantling lines for the main structural members are derived. These lines are extended to cover the range 30' to 50' which is generally outside the range of the above regulations

    Trawling pull exerted by a trawler: a method of estimation from propeller dimensions and its comparison with sea measurements

    Get PDF
    The proper matching of the pull exerted by a trawler and the size of trawl is important for maximizing the catching efficiency. The available pull is more dependent on the propeller and its working conditions than the installed engine power. The normal practice is to directly connect net size to the installed power in the boat by formulae without reference to the prope1ler dimensions or the available trawling pull and this is not adequate to find out the optimum combination. By the method outlined in this paper, the accurate calculation of trawling pull is possible by taking into account only the propeller diameter, pitch and r. p. m. The predictions by the method are compared for trawlers with powers between 30 and 60 hp and agreement is found to be within + 5%. The power absorbed by the propeller in trawling condition can also be calculated by this method for checking whether the engine is being overloaded

    Comparative fishing ability and economic efficiency of mechanised trawlers operating along the Kerala coast

    Get PDF
    This study was undertaken with a view to finding out the comparative fishing ability and economic performance of different fishing vessel sizes 9.15m (30'), 9.76m (32') and 10.97m (36') designed by the Central Institute of Fisheries Technology and operating along the Kerala coast. Data were collected from selected vessels of these sizes for four consecutive fishing seasons from 1964-65 to 1967-68. The catch/unit effort and total effort per year for the 10.97m (36') vessels were much better than those for the 9.76m (32') vessels. The yearly landings and the crew remuneration for the former were about twice those of the 9.76m (32') vessels. The economic efficiency of the 10.97m (36') vessels was also much better. The decline in landings per year in both size groups was more due to the reduction in the effort per year than the decline in catch/unit effort

    Search for the Chiral Magnetic Effect in Au+Au collisions at sNN=27\sqrt{s_{_{\rm{NN}}}}=27 GeV with the STAR forward Event Plane Detectors

    Full text link
    A decisive experimental test of the Chiral Magnetic Effect (CME) is considered one of the major scientific goals at the Relativistic Heavy-Ion Collider (RHIC) towards understanding the nontrivial topological fluctuations of the Quantum Chromodynamics vacuum. In heavy-ion collisions, the CME is expected to result in a charge separation phenomenon across the reaction plane, whose strength could be strongly energy dependent. The previous CME searches have been focused on top RHIC energy collisions. In this Letter, we present a low energy search for the CME in Au+Au collisions at sNN=27\sqrt{s_{_{\rm{NN}}}}=27 GeV. We measure elliptic flow scaled charge-dependent correlators relative to the event planes that are defined at both mid-rapidity η<1.0|\eta|<1.0 and at forward rapidity 2.1<η<5.12.1 < |\eta|<5.1. We compare the results based on the directed flow plane (Ψ1\Psi_1) at forward rapidity and the elliptic flow plane (Ψ2\Psi_2) at both central and forward rapidity. The CME scenario is expected to result in a larger correlation relative to Ψ1\Psi_1 than to Ψ2\Psi_2, while a flow driven background scenario would lead to a consistent result for both event planes[1,2]. In 10-50\% centrality, results using three different event planes are found to be consistent within experimental uncertainties, suggesting a flow driven background scenario dominating the measurement. We obtain an upper limit on the deviation from a flow driven background scenario at the 95\% confidence level. This work opens up a possible road map towards future CME search with the high statistics data from the RHIC Beam Energy Scan Phase-II.Comment: main: 8 pages, 5 figures; supplementary material: 2 pages, 1 figur

    Measurements of differential production cross sections for a Z boson in association with jets in pp collisions at root s=8 TeV

    Get PDF
    Peer reviewe

    Observation of a new boson at a mass of 125 GeV with the CMS experiment at the LHC

    Get PDF

    SARS-CoV-2-specific nasal IgA wanes 9 months after hospitalisation with COVID-19 and is not induced by subsequent vaccination

    Get PDF
    BACKGROUND: Most studies of immunity to SARS-CoV-2 focus on circulating antibody, giving limited insights into mucosal defences that prevent viral replication and onward transmission. We studied nasal and plasma antibody responses one year after hospitalisation for COVID-19, including a period when SARS-CoV-2 vaccination was introduced. METHODS: In this follow up study, plasma and nasosorption samples were prospectively collected from 446 adults hospitalised for COVID-19 between February 2020 and March 2021 via the ISARIC4C and PHOSP-COVID consortia. IgA and IgG responses to NP and S of ancestral SARS-CoV-2, Delta and Omicron (BA.1) variants were measured by electrochemiluminescence and compared with plasma neutralisation data. FINDINGS: Strong and consistent nasal anti-NP and anti-S IgA responses were demonstrated, which remained elevated for nine months (p < 0.0001). Nasal and plasma anti-S IgG remained elevated for at least 12 months (p < 0.0001) with plasma neutralising titres that were raised against all variants compared to controls (p < 0.0001). Of 323 with complete data, 307 were vaccinated between 6 and 12 months; coinciding with rises in nasal and plasma IgA and IgG anti-S titres for all SARS-CoV-2 variants, although the change in nasal IgA was minimal (1.46-fold change after 10 months, p = 0.011) and the median remained below the positive threshold determined by pre-pandemic controls. Samples 12 months after admission showed no association between nasal IgA and plasma IgG anti-S responses (R = 0.05, p = 0.18), indicating that nasal IgA responses are distinct from those in plasma and minimally boosted by vaccination. INTERPRETATION: The decline in nasal IgA responses 9 months after infection and minimal impact of subsequent vaccination may explain the lack of long-lasting nasal defence against reinfection and the limited effects of vaccination on transmission. These findings highlight the need to develop vaccines that enhance nasal immunity. FUNDING: This study has been supported by ISARIC4C and PHOSP-COVID consortia. ISARIC4C is supported by grants from the National Institute for Health and Care Research and the Medical Research Council. Liverpool Experimental Cancer Medicine Centre provided infrastructure support for this research. The PHOSP-COVD study is jointly funded by UK Research and Innovation and National Institute of Health and Care Research. The funders were not involved in the study design, interpretation of data or the writing of this manuscript

    Large-scale phenotyping of patients with long COVID post-hospitalization reveals mechanistic subtypes of disease

    Get PDF
    One in ten severe acute respiratory syndrome coronavirus 2 infections result in prolonged symptoms termed long coronavirus disease (COVID), yet disease phenotypes and mechanisms are poorly understood1. Here we profiled 368 plasma proteins in 657 participants ≥3 months following hospitalization. Of these, 426 had at least one long COVID symptom and 233 had fully recovered. Elevated markers of myeloid inflammation and complement activation were associated with long COVID. IL-1R2, MATN2 and COLEC12 were associated with cardiorespiratory symptoms, fatigue and anxiety/depression; MATN2, CSF3 and C1QA were elevated in gastrointestinal symptoms and C1QA was elevated in cognitive impairment. Additional markers of alterations in nerve tissue repair (SPON-1 and NFASC) were elevated in those with cognitive impairment and SCG3, suggestive of brain–gut axis disturbance, was elevated in gastrointestinal symptoms. Severe acute respiratory syndrome coronavirus 2-specific immunoglobulin G (IgG) was persistently elevated in some individuals with long COVID, but virus was not detected in sputum. Analysis of inflammatory markers in nasal fluids showed no association with symptoms. Our study aimed to understand inflammatory processes that underlie long COVID and was not designed for biomarker discovery. Our findings suggest that specific inflammatory pathways related to tissue damage are implicated in subtypes of long COVID, which might be targeted in future therapeutic trials

    Charged-particle nuclear modification factors in PbPb and pPb collisions at √=sNN=5.02 TeV

    Get PDF
    The spectra of charged particles produced within the pseudorapidity window |η| < 1 at √ sNN = 5.02 TeV are measured using 404 µb −1 of PbPb and 27.4 pb−1 of pp data collected by the CMS detector at the LHC in 2015. The spectra are presented over the transverse momentum ranges spanning 0.5 < pT < 400 GeV in pp and 0.7 < pT < 400 GeV in PbPb collisions. The corresponding nuclear modification factor, RAA, is measured in bins of collision centrality. The RAA in the 5% most central collisions shows a maximal suppression by a factor of 7–8 in the pT region of 6–9 GeV. This dip is followed by an increase, which continues up to the highest pT measured, and approaches unity in the vicinity of pT = 200 GeV. The RAA is compared to theoretical predictions and earlier experimental results at lower collision energies. The newly measured pp spectrum is combined with the pPb spectrum previously published by the CMS collaboration to construct the pPb nuclear modification factor, RpA, up to 120 GeV. For pT > 20 GeV, RpA exhibits weak momentum dependence and shows a moderate enhancement above unity
    corecore