3,436 research outputs found
On the geometry of the set of controllability subspaces of a pair (A,B)
AbstractGiven a controllable system defined by a pair of matrices (A,B), we investigate the geometry of the set of controllability subspaces. This set is a subset of the set of (A,B)-invariant subspaces. We prove that, in fact, it is a stratified submanifold and we compute its dimension
Versal deformations in orbit spaces
AbstractGiven an orbit space M/Γ and an equivalence relation defined in it by means of the action of a group G, we obtain a miniversal deformation of an orbit through a miniversal deformation in M with regard to a suitable group action of G×Γ. We show some applications to the perturbations of m-tuples of subspaces and (C,A)-invariant subspaces
A hybrid of 1-deoxynojirimycin and benzotriazole induces preferential inhibition of butyrylcholinesterase (BuChE) over acetylcholinesterase (AChE)
The synthesis of four heterodimers in which the copper(I)-catalysed azide-alkyne cycloaddition was employed to connect a 1-deoxynojirimycin moiety with a benzotriazole scaffold is reported. The heterodimers were investigated as inhibitors against acetylcholinesterase (AChE) and butyrylcholinesterase (BuChE). The heterodimers displayed preferential inhibition (> 9) of BuChE over AChE in the micromolar concentration range (IC50 = 7–50 µM). For the most potent inhibitor of BuChE, Cornish-Bowden plots were used, which demonstrated that it behaves as a mixed inhibitor. Modelling studies of the same inhibitor demonstrated that the benzotriazole and 1-deoxynojirimycin moiety is accommodated in the peripheral anionic site and catalytic anionic site, respectively, of AChE. The binding mode to BuChE was different as the benzotriazole moiety is accommodated in the catalytic anionic site.publishedVersio
A Comprehensive Evaluation of Sdox, a Promising H2S-Releasing Doxorubicin for the Treatment of Chemoresistant Tumors
Sdox is a hydrogen sulfide (H2S)-releasing doxorubicin effective in P-glycoprotein-overexpressing/doxorubicin-resistant tumor models and not cytotoxic, as the parental drug, in H9c2 cardiomyocytes. The aim of this study was the assessment of Sdox drug-like features and its absorption, distribution, metabolism, and excretion (ADME)/toxicity properties, by a multi- and transdisciplinary in silico, in vitro, and in vivo approach. Doxorubicin was used as the reference compound. The in silico profiling suggested that Sdox possesses higher lipophilicity and lower solubility compared to doxorubicin, and the off-targets prediction revealed relevant differences between Dox and Sdox towards several cancer targets, suggesting different toxicological profiles. In vitro data showed that Sdox is a substrate with lower affinity for P-glycoprotein, less hepatotoxic, and causes less oxidative damage than doxorubicin. Both anthracyclines inhibited CYP3A4, but not hERG currents. Unlike doxorubicin, the percentage of zebrafish live embryos at 72 hpf was not affected by Sdox treatment. In conclusion, these findings demonstrate that Sdox displays a more favorable drug-like ADME/toxicity profile than doxorubicin, different selectivity towards cancer targets, along with a greater preclinical efficacy in resistant tumors. Therefore, Sdox represents a prototype of innovative anthracyclines, worthy of further investigations in clinical settings
Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air
[EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. Finally, we thank Brendon Bullard, Paolo Giromini and Neeraj Tata for helpful discussions and assistance with preliminary measurements.Ghosh, S.; Haefner, J.; Martín-Albo, J.; Guenette, R.; Li, X.; Loya Villalpando, A.; Burch, C.... (2020). Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air. Journal of Instrumentation. 15(11):1-17. https://doi.org/10.1088/1748-0221/15/11/P11031S1171511Auger, M., Auty, D. J., Barbeau, P. S., Bartoszek, L., Baussan, E., Beauchamp, E., … Cleveland, B. (2012). The EXO-200 detector, part I: detector design and construction. Journal of Instrumentation, 7(05), P05010-P05010. doi:10.1088/1748-0221/7/05/p05010Martín-Albo, J., Muñoz Vidal, J., Ferrario, P., Nebot-Guinot, M., Gómez-Cadenas, J. J., … Cárcel, S. (2016). Sensitivity of NEXT-100 to neutrinoless double beta decay. Journal of High Energy Physics, 2016(5). doi:10.1007/jhep05(2016)159Rogers, L., Clark, R. A., Jones, B. J. P., McDonald, A. D., Nygren, D. R., Psihas, F., … Azevedo, C. D. . (2018). High voltage insulation and gas absorption of polymers in high pressure argon and xenon gases. Journal of Instrumentation, 13(10), P10002-P10002. doi:10.1088/1748-0221/13/10/p10002Silva, C., Pinto da Cunha, J., Pereira, A., Chepel, V., Lopes, M. I., Solovov, V., & Neves, F. (2010). Reflectance of polytetrafluoroethylene for xenon scintillation light. Journal of Applied Physics, 107(6), 064902. doi:10.1063/1.3318681Haefner, J., Neff, A., Arthurs, M., Batista, E., Morton, D., Okunawo, M., … Lorenzon, W. (2017). Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 856, 86-91. doi:10.1016/j.nima.2017.01.057Kravitz, S., Smith, R. J., Hagaman, L., Bernard, E. P., McKinsey, D. N., Rudd, L., … Sakai, M. (2020). Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX. The European Physical Journal C, 80(3). doi:10.1140/epjc/s10052-020-7800-6Geis, C., Grignon, C., Oberlack, U., García, D. R., & Weitzel, Q. (2017). Optical response of highly reflective film used in the water Cherenkov muon veto of the XENON1T dark matter experiment. Journal of Instrumentation, 12(06), P06017-P06017. doi:10.1088/1748-0221/12/06/p06017Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., … Barrand, G. (2016). Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 835, 186-225. doi:10.1016/j.nima.2016.06.12
Safety of vaccination against SARS-CoV-2 in people with rheumatic and musculoskeletal diseases: results from the EULAR Coronavirus Vaccine (COVAX) physician-reported registry
OBJECTIVES: To describe the safety of vaccines against SARS-CoV-2 in people with inflammatory/autoimmune rheumatic and musculoskeletal disease (I-RMD). METHODS: Physician-reported registry of I-RMD and non-inflammatory RMD (NI-RMDs) patients vaccinated against SARS-CoV-2. From 5 February 2021 to 27 July 2021, we collected data on demographics, vaccination, RMD diagnosis, disease activity, immunomodulatory/immunosuppressive treatments, flares, adverse events (AEs) and SARS-CoV-2 breakthrough infections. Data were analysed descriptively. RESULTS: The study included 5121 participants from 30 countries, 90% with I-RMDs (n=4604, 68% female, mean age 60.5 years) and 10% with NI-RMDs (n=517, 77% female, mean age 71.4). Inflammatory joint diseases (58%), connective tissue diseases (18%) and vasculitis (12%) were the most frequent diagnostic groups; 54% received conventional synthetic disease-modifying antirheumatic drugs (DMARDs), 42% biological DMARDs and 35% immunosuppressants. Most patients received the Pfizer/BioNTech vaccine (70%), 17% AstraZeneca/Oxford and 8% Moderna. In fully vaccinated cases, breakthrough infections were reported in 0.7% of I-RMD patients and 1.1% of NI-RMD patients. I-RMD flares were reported in 4.4% of cases (0.6% severe), 1.5% resulting in medication changes. AEs were reported in 37% of cases (37% I-RMD, 40% NI-RMD), serious AEs in 0.5% (0.4% I-RMD, 1.9% NI-RMD). CONCLUSION: The safety profiles of SARS-CoV-2 vaccines in patients with I-RMD was reassuring and comparable with patients with NI-RMDs. The majority of patients tolerated their vaccination well with rare reports of I-RMD flare and very rare reports of serious AEs. These findings should provide reassurance to rheumatologists and vaccine recipients and promote confidence in SARS-CoV-2 vaccine safety in I-RMD patients
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Combined search for the quarks of a sequential fourth generation
Results are presented from a search for a fourth generation of quarks
produced singly or in pairs in a data set corresponding to an integrated
luminosity of 5 inverse femtobarns recorded by the CMS experiment at the LHC in
2011. A novel strategy has been developed for a combined search for quarks of
the up and down type in decay channels with at least one isolated muon or
electron. Limits on the mass of the fourth-generation quarks and the relevant
Cabibbo-Kobayashi-Maskawa matrix elements are derived in the context of a
simple extension of the standard model with a sequential fourth generation of
fermions. The existence of mass-degenerate fourth-generation quarks with masses
below 685 GeV is excluded at 95% confidence level for minimal off-diagonal
mixing between the third- and the fourth-generation quarks. With a mass
difference of 25 GeV between the quark masses, the obtained limit on the masses
of the fourth-generation quarks shifts by about +/- 20 GeV. These results
significantly reduce the allowed parameter space for a fourth generation of
fermions.Comment: Replaced with published version. Added journal reference and DO
Measurement of the Z/gamma* + b-jet cross section in pp collisions at 7 TeV
The production of b jets in association with a Z/gamma* boson is studied
using proton-proton collisions delivered by the LHC at a centre-of-mass energy
of 7 TeV and recorded by the CMS detector. The inclusive cross section for
Z/gamma* + b-jet production is measured in a sample corresponding to an
integrated luminosity of 2.2 inverse femtobarns. The Z/gamma* + b-jet cross
section with Z/gamma* to ll (where ll = ee or mu mu) for events with the
invariant mass 60 < M(ll) < 120 GeV, at least one b jet at the hadron level
with pT > 25 GeV and abs(eta) < 2.1, and a separation between the leptons and
the jets of Delta R > 0.5 is found to be 5.84 +/- 0.08 (stat.) +/- 0.72 (syst.)
+(0.25)/-(0.55) (theory) pb. The kinematic properties of the events are also
studied and found to be in agreement with the predictions made by the MadGraph
event generator with the parton shower and the hadronisation performed by
PYTHIA.Comment: Submitted to the Journal of High Energy Physic
- …