637 research outputs found

    Inhibitory action of Lippia gracilis Schauer essential oil on pathogenic bacteria and its effects as a growth promoter on quail

    Get PDF
    Aim of the study: To examine the in vitro sensitivity of Salmonella sp. and Escherichia coli strains to the microbial activity of Lippia gracilis Schauer essential oil (LGSEO) and to determine the optimal level of LGSEO as a growth promoter in diets for Japanese quail up to 35 days of age.Area of study: São Cristovão, Sergipe, Brazil.Material and methods: A total of 504 female Japanese quails (Coturnix coturnix japonica) at an initial average body weights of 6.80±0.10 g was allotted to one of six treatments (0, 100, 200, 300, 400 mg/kg of LGSEO and a diet containing 500 mg/kg of bacitracin methylene disalicylate) in 7 replicates, using 12 birds per experimental unit.Main results: In the age period of 21 to 35 days, feed intake declined linearly (p=0.04) and feed efficiency improved (p<0.01), whereas no changes were observed in production performance (p>0.05). The estimated (p=0.01) maximum relative weights of proventriculus and pancreas were obtained at the LGSEO inclusion levels of 196.5 and 251 mg/kg, respectively. Inclusion of 100 to 300 mg/kg of LGSEO in the diet reduced the total Salmonella sp. bacterial count.Research highlights: The use of 196.5 mg/kg of LGSEO in the diet of Japanese quail improved production performance and organ development and demonstrated potential antimicrobial capacity against Salmonella sp. bacteria. Due its pharmacological composition, LGSEO can potentially substitute to antimicrobials, because contains thymol and carvacrol as main active constituents

    Stellar occultations enable milliarcsecond astrometry for Trans-Neptunian objects and Centaurs

    Get PDF
    Trans-Neptunian objects (TNOs) and Centaurs are remnants of our planetary system formation, and their physical properties have invaluable information for evolutionary theories. Stellar occultation is a ground-based method for studying these small bodies and has presented exciting results. These observations can provide precise profiles of the involved body, allowing an accurate determination of its size and shape. The goal is to show that even single-chord detections of TNOs allow us to measure their milliarcsecond astrometric positions in the reference frame of the Gaia second data release (DR2). Accurated ephemerides can then be generated, allowing predictions of stellar occultations with much higher reliability. We analyzed data from stellar occultations to obtain astrometric positions of the involved bodies. The events published before the Gaia era were updated so that the Gaia DR2 catalog is the reference. Previously determined sizes were used to calculate the position of the object center and its corresponding error with respect to the detected chord and the International Celestial Reference System (ICRS) propagated Gaia DR2 star position. We derive 37 precise astrometric positions for 19 TNOs and 4 Centaurs. Twenty-one of these events are presented here for the first time. Although about 68\% of our results are based on single-chord detection, most have intrinsic precision at the submilliarcsecond level. Lower limits on the diameter and shape constraints for a few bodies are also presented as valuable byproducts. Using the Gaia DR2 catalog, we show that even a single detection of a stellar occultation allows improving the object ephemeris significantly, which in turn enables predicting a future stellar occultation with high accuracy. Observational campaigns can be efficiently organized with this help, and may provide a full physical characterization of the involved object.Comment: 16 pages, 28 figures. The manuscript was accepted and is to be publishe

    An open-label, 1-year extension study of the long-term safety and efficacy of once-daily OROS® hydromorphone in patients with chronic cancer pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Opioid analgesics have proven efficacy in the short-term management of chronic cancer pain, but data on their long-term use is more limited. OROS<sup>® </sup>hydromorphone is a controlled-release formulation of oral hydromorphone that may be particularly well suited to long-term management of chronic cancer pain because it provides stable plasma concentrations and consistent analgesia with convenient once-daily dosing. The objective of this study (DO-118X) was to characterise the pain control achieved with long-term repeated dosing of OROS<sup>® </sup>hydromorphone in patients with chronic cancer pain.</p> <p>Methods</p> <p>In this multicentre, phase III, open-label, single treatment, 1-year extension study, OROS<sup>® </sup>hydromorphone was administered to 68 patients with moderate-to-severe chronic cancer pain, who had successfully completed a short-term equivalence study, and whose pain was controlled with a stable dose of medication (≥ 8 mg OROS<sup>® </sup>hydromorphone or equivalent controlled-release morphine). Patients were started on the dose of OROS<sup>® </sup>hydromorphone equivalent to the opioid dose on which they achieved dose-stable pain control in the equivalence study; dose adjustments were made as necessary and breakthrough pain medication was permitted. Efficacy was assessed with the Brief Pain Inventory (BPI) and patient and investigator global evaluations of treatment effectiveness. No formal statistical analysis was done.</p> <p>Results</p> <p>The mean (standard deviation) duration of exposure to study medication was 139 (129.9) days and the mean (standard deviation) average daily consumption of OROS<sup>® </sup>hydromorphone was 43.7 (28.14) mg/day. All scores were maintained at a mild to moderate severity throughout the study; however, BPI scores for pain at its worst, pain at its least, pain on average, pain right now, and pain relief were slightly worsened at end point compared with baseline. Mean BPI pain interference with daily activities and patient and investigator global evaluation scores also remained generally stable. Treatment effectiveness was rated as fair to good throughout the study. The most frequently reported adverse events were nausea (n = 24, 35.3%), constipation (n = 22, 32.4%), and vomiting (n = 15, 22.1%).</p> <p>Conclusion</p> <p>The results of this extension study suggest that long-term repeated dosing with once-daily OROS<sup>® </sup>hydromorphone can be beneficial in the continuing management of persistent, moderate-to-severe cancer pain.</p

    Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks

    Full text link
    We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series. Each of the lowest components produces clock errors with unique characteristics that must be assessed to establish a clock's accuracy. We describe the errors and how to evaluate them. We prove that sharp structures in the cavity do not produce large frequency errors, even at moderately high powers, provided the atomic density varies slowly. We model the amplitude and phase imbalances of the feeds. For larger couplings, these can lead to increased phase errors. We show that phase imbalances produce a novel distributed cavity phase error that depends on the cavity detuning. We also design improved cavities by optimizing the geometry and tuning the mode spectrum so that there are negligible phase variations, allowing this source of systematic error to be dramatically reduced.Comment: To appear in Metrologi

    Characterization of crop residues from false banana/Ensete ventricosum/in Ethiopia in view of a full-resource valorization

    Get PDF
    Research ArticleFalse banana /Ensete ventricosum [Welw.] Cheesman/ is exploited as a food crop in Ethiopia where it represents an important staple food. The plant is harvested and large amounts of biomass residues are originated, mainly from the pseudo stem (i.e., fiber bundles obtained from the leaf sheaths after being scrapped to produce starchy food) and the inflorescence stalk. These materials were studied in relation to their summative chemical composition, composition of lignin, lipophilic and polar extracts. Moreover, their structural characteristics, in view of their valorization, were scrutinized. The analytical studies were performed with the aid of FTIR, GC/MS, Py-GC/MS and SEM. The fiber bundles are aggregates of mainly long and slender fibers with low ash, extractives and lignin contents (3.8%. 4.4% and 10.5% respectively) and high holocellulose and α-cellulose contents (87.5% and 59.6% respectively). The hemicelluloses in the fibers are mostly highly acetylated xylans and the lignin is of the H-type (H:G:S, 1:0.7:0.8). This lignin composition is in line with the FTIR peaks at 1670 cm-1 and 1250 cm-1.The inflorescence stalk has high ash content (12.3% in the main stalk and 24.6% in fines) with a major proportion of potassium, high extractives (25.9%), and low lignin and α-cellulose contents (5.8% and 17.9% respectively). The stalk includes numerous starch granules in the cellular structure with the predominant presence of parenchyma. The potential valorization routes for these materials are clearly different. The fiber bundles could be used as a fiber source for paper pulp production with the possibility of a prior hemicelluloses removal while the inflorescence stalk has nutritional value for food and fodder. Furthermore, it can also be used for sugar fermentation productsinfo:eu-repo/semantics/publishedVersio

    Baseline characteristics of patients in the reduction of events with darbepoetin alfa in heart failure trial (RED-HF)

    Get PDF
    &lt;p&gt;Aims: This report describes the baseline characteristics of patients in the Reduction of Events with Darbepoetin alfa in Heart Failure trial (RED-HF) which is testing the hypothesis that anaemia correction with darbepoetin alfa will reduce the composite endpoint of death from any cause or hospital admission for worsening heart failure, and improve other outcomes.&lt;/p&gt; &lt;p&gt;Methods and results: Key demographic, clinical, and laboratory findings, along with baseline treatment, are reported and compared with those of patients in other recent clinical trials in heart failure. Compared with other recent trials, RED-HF enrolled more elderly [mean age 70 (SD 11.4) years], female (41%), and black (9%) patients. RED-HF patients more often had diabetes (46%) and renal impairment (72% had an estimated glomerular filtration rate &#60;60 mL/min/1.73 m2). Patients in RED-HF had heart failure of longer duration [5.3 (5.4) years], worse NYHA class (35% II, 63% III, and 2% IV), and more signs of congestion. Mean EF was 30% (6.8%). RED-HF patients were well treated at randomization, and pharmacological therapy at baseline was broadly similar to that of other recent trials, taking account of study-specific inclusion/exclusion criteria. Median (interquartile range) haemoglobin at baseline was 112 (106–117) g/L.&lt;/p&gt; &lt;p&gt;Conclusion: The anaemic patients enrolled in RED-HF were older, moderately to markedly symptomatic, and had extensive co-morbidity.&lt;/p&gt

    Search for post-merger gravitational waves from the remnant of the binary neutron star merger GW170817

    No full text
    In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz

    First measurement of the Hubble Constant from a Dark Standard Siren using the Dark Energy Survey Galaxies and the LIGO/Virgo Binary–Black-hole Merger GW170814

    Get PDF
    International audienceWe present a multi-messenger measurement of the Hubble constant H 0 using the binary–black-hole merger GW170814 as a standard siren, combined with a photometric redshift catalog from the Dark Energy Survey (DES). The luminosity distance is obtained from the gravitational wave signal detected by the Laser Interferometer Gravitational-Wave Observatory (LIGO)/Virgo Collaboration (LVC) on 2017 August 14, and the redshift information is provided by the DES Year 3 data. Black hole mergers such as GW170814 are expected to lack bright electromagnetic emission to uniquely identify their host galaxies and build an object-by-object Hubble diagram. However, they are suitable for a statistical measurement, provided that a galaxy catalog of adequate depth and redshift completion is available. Here we present the first Hubble parameter measurement using a black hole merger. Our analysis results in , which is consistent with both SN Ia and cosmic microwave background measurements of the Hubble constant. The quoted 68% credible region comprises 60% of the uniform prior range [20, 140] km s−1 Mpc−1, and it depends on the assumed prior range. If we take a broader prior of [10, 220] km s−1 Mpc−1, we find (57% of the prior range). Although a weak constraint on the Hubble constant from a single event is expected using the dark siren method, a multifold increase in the LVC event rate is anticipated in the coming years and combinations of many sirens will lead to improved constraints on H 0

    Biallelic variants in KARS1 are associated with neurodevelopmental disorders and hearing loss recapitulated by the knockout zebrafish

    Get PDF
    Purpose: Pathogenic variants in Lysyl-tRNA synthetase 1 (KARS1) have increasingly been recognized as a cause of early-onset complex neurological phenotypes. To advance the timely diagnosis of KARS1-related disorders, we sought to delineate its phenotype and generate a disease model to understand its function in vivo. Methods: Through international collaboration, we identified 22 affected individuals from 16 unrelated families harboring biallelic likely pathogenic or pathogenic in KARS1 variants. Sequencing approaches ranged from disease-specific panels to genome sequencing. We generated loss-of-function alleles in zebrafish. Results: We identify ten new and four known biallelic missense variants in KARS1 presenting with a moderate-to-severe developmental delay, progressive neurological and neurosensory abnormalities, and variable white matter involvement. We describe novel KARS1-associated signs such as autism, hyperactive behavior, pontine hypoplasia, and cerebellar atrophy with prevalent vermian involvement. Loss of kars1 leads to upregulation of p53, tissue-specific apoptosis, and downregulation of neurodevelopmental related genes, recapitulating key tissue-specific disease phenotypes of patients. Inhibition of p53 rescued several defects of kars1−/− knockouts. Conclusion: Our work delineates the clinical spectrum associated with KARS1 defects and provides a novel animal model for KARS1-related human diseases revealing p53 signaling components as potential therapeutic targets
    corecore