554 research outputs found

    Assessment of two types of passive sampler for the efficient recovery of SARS-CoV-2 and other viruses from wastewater

    Get PDF
    Wastewater-based epidemiology (WBE) has proven to be a useful surveillance tool during the ongoing SARS-CoV-2 pandemic, and has driven research into evaluating the most reliable and cost-effective techniques for obtaining a representative sample of wastewater. When liquid samples cannot be taken efficiently, passive sampling approaches have been used, however, insufficient data exists on their usefulness for multi-virus capture and recovery. In this study, we compared the virus-binding capacity of two passive samplers (cotton-based tampons and ion exchange filter papers) in two different water types (deionised water and wastewater). Here we focused on the capture of wastewater-associated viruses including Influenza A and B (Flu-A & B), SARS-CoV-2, human adenovirus (AdV), norovirus GII (NoVGII), measles virus (MeV), pepper mild mottle virus (PMMoV), the faecal marker crAssphage and the process control virus Pseudomonas virus phi6. After deployment, we evaluated four different methods to recover viruses from the passive samplers namely, (i) phosphate buffered saline (PBS) elution followed by polyethylene glycol (PEG) precipitation, (ii) beef extract (BE) elution followed by PEG precipitation, (iii) no-elution into PEG precipitation, and (iv) direct extraction. We found that the tampon-based passive samplers had higher viral recoveries in comparison to the filter paper. Overall, the preferred viral recovery method from the tampon passive samplers was the no-elution/PEG precipitation method. Furthermore, we evidenced that non-enveloped viruses had higher percent recoveries from the passive samplers than enveloped viruses. This is the first study of its kind to assess passive sampler and viral recovery methods amongst a plethora of viruses commonly found in wastewater or used as a viral surrogate in wastewater studies

    A comparison of precipitation and filtration-based SARS-CoV-2 recovery methods and the influence of temperature, turbidity, and surfactant load in urban wastewater

    Get PDF
    Wastewater-based epidemiology (WBE) has become a complimentary surveillance tool during the SARS-CoV-2 pandemic. Viral concentration methods from wastewater are still being optimised and compared, whilst viral recovery under different wastewater characteristics and storage temperatures remains poorly understood. Using urban wastewater samples, we tested three viral concentration methods; polyethylene glycol precipitation (PEG), ammonium sulphate precipitation (AS), and CP selectℱ InnovaPrep¼ (IP) ultrafiltration. We found no major difference in SARS-CoV-2 and faecal indicator virus (crAssphage) recovery from wastewater samples (n = 46) using these methods, PEG slightly (albeit non-significantly), outperformed AS and IP for SARS-CoV-2 detection, as a higher genome copies per litre (gc/l) was recorded for a larger proportion of samples. Next generation sequencing of 8 paired samples revealed non-significant differences in the quality of data between AS and IP, though IP data quality was slightly better and less variable. A controlled experiment assessed the impact of wastewater suspended solids (turbidity; 0–400 NTU), surfactant load (0–200 mg/l), and storage temperature (5–20 °C) on viral recovery using the AS and IP methods. SARS-CoV-2 recoveries were >20% with AS and 0.05), whilst surfactant and storage temperature combined were significant negative correlates (p < 0.001 and p < 0.05, respectively). In conclusion, our results show that choice of methodology had small effect on viral recovery of SARS-CoV-2 and crAssphage in wastewater samples within this study. In contrast, sample turbidity, storage temperature, and surfactant load did affect viral recovery, highlighting the need for careful consideration of the viral concentration methodology used when working with wastewater samples

    Multi-factor normalisation of viral counts from wastewater improves the detection accuracy of viral disease in the community

    Get PDF
    The detection of viruses (e.g. SARS-CoV-2, norovirus) in wastewater represents an effective way to monitor the prevalence of these pathogens circulating within the community. However, accurate quantification of viral concentrations in wastewater, proportional to human input, is constrained by a range of uncertainties, including (i) dilution within the sewer network, (ii) degradation of viral RNA during wastewater transit, (iii) catchment population and facility use, (iv) efficiency of viral concentration and extraction from wastewater, and (v) inhibition of amplification during the RT-qPCR step. Here, we address these uncertainties by investigating several potential normalisation factors including the concentration of ammonium and orthophosphate. A faecal indicator virus (crAssphage), and the recovery of the process-control viruses (murine norovirus and bacteriophage Phi6), used for quality control during the RT-qPCR step, were also considered. We found that multi-factor normalisation of SARS-CoV-2 RT-qPCR data was optimal using a combination of crAssphage, process-control virus recovery, and concentration efficiency to improve prediction accuracy relative to clinical test data. Using multi-normalised SARS-CoV-2 RT-qPCR data, we found a lasso regression model with random forest modelled residuals lowers the prediction error of positives by 46 %, compared to a single linear regression using raw data. This multi-normalised approach enables more accurate wastewater-based predictions of clinical cases up to five days in advance of clinical data, identifying trends in disease prevalence before clinical testing, and demonstrates the potential to improve viral pathogen detection for a range of currently monitored and emerging diseases

    Use of wastewater from passenger ships to assess the movement of COVID-19 and other pathogenic viruses across maritime international boundaries

    Get PDF
    Objective:: The worldwide spread of SARS-CoV-2 and the resulting COVID-19 pandemic has been driven by international travel. This has led to the desire to develop surveillance approaches which can estimate the rate of import of pathogenic organisms across international borders. The aim of this study was to investigate the use of wastewater-based approaches for the surveillance of viral pathogens on commercial short-haul (3.5 h transit time) roll-on/roll-off passenger/freight ferries operating between the UK and the Republic of Ireland. Methods: Samples of toilet-derived wastewater (blackwater) were collected from two commercial ships over a 4-week period and analysed for SARS-CoV-2, influenza, enterovirus, norovirus, the faecal-marker virus crAssphage and a range of physical and chemical indicators of wastewater quality. Results: A small proportion of the wastewater samples were positive for SARS-CoV-2 (8% of the total), consistent with theoretical predictions of detection frequency (4%–15% of the total) based on the national COVID-19 Infection Survey and defecation behaviour. In addition, norovirus was detected in wastewater at low frequency. No influenza A/B viruses, enterovirus or enterovirus D68 were detected throughout the study period. Conclusion: We conclude that testing of wastewater from ships that cross international maritime boundaries may provide a cost-effective and relatively unbiased method to estimate the flow of infected individuals between countries. The approach is also readily applicable for the surveillance of other disease-causing agents

    Critical evaluation of different passive sampler materials and approaches for the recovery of SARS-CoV-2, faecal-indicator viruses and bacteria from wastewater

    Get PDF
    During the COVID-19 pandemic, wastewater-based epidemiology (WBE) has proven to be an effective tool for monitoring the prevalence of SARS-CoV-2 in urban communities. However, low-cost, simple, and reliable wastewater sampling techniques are still needed to promote the widespread adoption of WBE in many countries. Since their first use for public health surveillance in the 1950s, many types of passive samplers have been proposed, however, there have been few systematic studies comparing their ability to co-capture enveloped viruses and bacteria. Here, we evaluated the laboratory and field performance of 8 passive sampler materials (NanoCeram, ZetaPlus, nylon and ion exchange membranes, cellulose acetate filters, glass wool, cotton-based Moore swabs and tampons) to capture viruses and bacteria from wastewater. Viral capture focused on SARS-CoV-2, the bacteriophage Phi6 and the faecal marker virus, crAssphage. We showed that the best performing passive sampler in terms of cost, ease of deployment and viral capture were the electronegative cotton-based swabs and tampons. We speculate that viral capture is a combination of trapping of particulate matter to which viruses are attached, as well as electrostatic attraction of viral particles from solution. When deployed at wastewater treatment plants, the passive samplers worked best up to 6 h, after which they became saturated or exhibited a loss of virus, probably due to night-time wash-out. The patterns of viral capture across the different sampling materials were similar providing evidence that they can be used to monitor multiple public health targets. The types of bacteria trapped by the passive samplers were material-specific, but possessed a different 16S rRNA gene profile to the wastewater, suggesting preferential retention of specific bacteria. We conclude that the choice of passive sampler and deployment time greatly influences the pattern and amount of viral and bacterial capture

    Examining the stability of viral RNA and DNA in wastewater: Effects of storage time, temperature, and freeze-thaw cycles

    Get PDF
    Wastewater-based epidemiology (WBE) has been demonstrably successful as a relatively unbiased tool for monitoring levels of SARS-CoV-2 virus circulating in communities during the COVID-19 pandemic. Accumulated biobanks of wastewater samples allow retrospective exploration of spatial and temporal trends for public health indicators such as chemicals, viruses, antimicrobial resistance genes, and the possible emergence of novel human or zoonotic pathogens. We investigated virus resilience to time, temperature, and freeze-thaw cycles, plus the optimal storage conditions to maintain the stability of genetic material (RNA/DNA) of viral +ssRNA (Envelope – E, Nucleocapsid – N and Spike protein – S genes of SARS-CoV-2), dsRNA (Phi6 phage) and circular dsDNA (crAssphage) in wastewater. Samples consisted of (i) processed and extracted wastewater samples, (ii) processed and extracted distilled water samples, and (iii) raw, unprocessed wastewater samples. Samples were stored at –80 °C, –20 °C, 4 °C, or 20 °C for 10 days, going through up to 10 freeze-thaw cycles (once per day). Sample stability was measured using reverse transcription quantitative PCR, quantitative PCR, automated electrophoresis, and short-read whole genome sequencing. Exploring different areas of the SARS-CoV-2 genome demonstrated that the S gene in processed and extracted samples showed greater sensitivity to freeze-thaw cycles than the E or N genes. Investigating surrogate and normalisation viruses showed that Phi6 remains a stable comparison for SARS-CoV-2 in a laboratory setting and crAssphage was relatively resilient to temperature variation. Recovery of SARS-CoV-2 in raw unprocessed samples was significantly greater when stored at 4 °C, which was supported by the sequencing data for all viruses – both time and freeze-thaw cycles negatively impacted sequencing metrics. Historical extracts stored at –80 °C that were re-quantified 12, 14 and 16 months after original quantification showed no major changes. This study highlights the importance of the fast processing and extraction of wastewater samples, following which viruses are relatively robust to storage at a range of temperatures

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Measurement of the top quark forward-backward production asymmetry and the anomalous chromoelectric and chromomagnetic moments in pp collisions at √s = 13 TeV

    Get PDF
    Abstract The parton-level top quark (t) forward-backward asymmetry and the anomalous chromoelectric (d̂ t) and chromomagnetic (Ό̂ t) moments have been measured using LHC pp collisions at a center-of-mass energy of 13 TeV, collected in the CMS detector in a data sample corresponding to an integrated luminosity of 35.9 fb−1. The linearized variable AFB(1) is used to approximate the asymmetry. Candidate t t ÂŻ events decaying to a muon or electron and jets in final states with low and high Lorentz boosts are selected and reconstructed using a fit of the kinematic distributions of the decay products to those expected for t t ÂŻ final states. The values found for the parameters are AFB(1)=0.048−0.087+0.095(stat)−0.029+0.020(syst),Ό̂t=−0.024−0.009+0.013(stat)−0.011+0.016(syst), and a limit is placed on the magnitude of | d̂ t| &lt; 0.03 at 95% confidence level. [Figure not available: see fulltext.

    Measurement of t(t)over-bar normalised multi-differential cross sections in pp collisions at root s=13 TeV, and simultaneous determination of the strong coupling strength, top quark pole mass, and parton distribution functions

    Get PDF
    Peer reviewe
    • 

    corecore