1,971 research outputs found

    Effects of Late Conversion from Twice-Daily to Once-Daily Slow Release Tacrolimus on the Insulin Resistance Indexes in Kidney Transplant Patients

    Get PDF
    The use of tacrolimus (Tac) may be involved in the development of new-onset diabetes after transplantation (NODAT) in a dose-related manner. This study aimed to evaluate the effects of a standard twice-daily formulation of Tac (TacBID) vs. the once-daily slow-release formulation (TacOD) on the basal insulin resistance indexes (Homa and McAuley), and related metabolic parameters, in a cohort of kidney transplant patients. We retrospectively evaluated 20 stable renal transplant recipients who were switched from TacBID to TacOD. Blood levels of Tac were analyzed at one-month intervals from 6 months before to 8 months after conversion. Moreover, Homa and McAuley indexes, C-peptide, insulin, HbA1c, uric acid, triglycerides, low-density lipoprotein (LDL) and high-density lipoprotein (HDL)-cholesterol serum levels and their associations with Tac levels were evaluated. We observed a significant decrease in Tac exposure (8.5 ± 2 ng/mL, CV 0.23 vs. 6.1 ± 1.9 ng/mL, CV 0.31, TacBID vs. TacOD periods, p 0.05) and McAuley indexes (7.12 ± 1 vs. 7.58 ± 1.4, p > 0.05). Similarly, blood levels of glucose, insulin, HbA1c, lipids, and uric acid were unchanged between the two periods, while C-peptide resulted significantly lower after conversion to TacOD. These data suggest that in kidney transplant recipients, reduced Tac exposure has no significant effects on basal insulin sensitivity indexes and metabolic parameters

    Impaired Left Ventricular Global Longitudinal Strain among Patients with Chronic Kidney Disease and End-Stage Renal Disease and Renal Transplant Recipients

    Get PDF
    Background: Although heart failure is the most prevalent cardiovascular disease associated with adverse outcome in chronic kidney disease (CKD) and after kidney transplantation, left ventricular (LV) systolic function is often preserved in renal patients. The aim of this study was to evaluate global longitudinal strain (GLS), which is reportedly a more accurate tool for detecting subclinical LV systolic dysfunction, in patients with various degrees of renal function impairment, including kidney transplant recipients (KTRs). Methods: This prospective study evaluated demographic, clinical, and ultrasound data, including the assessment of LV GLS and mitral E peak velocity and averaged ratio of mitral to myocardial early velocities (E/e'), of 70 consecutive renal patients (20 with stage 2-4 CKD, 25 with end-stage renal disease on hemodialysis [HD], and 25 KTRs). All patients had an LV ejection fraction 6550% and no history of heart failure or coronary artery disease. We used multivariable logistic analysis to assess the risk of compromised GLS. One hundred and twenty control subjects with or without hypertension served as controls. Results: A compromised GLS <-18% was shown in 55% of patients with stage 2-4 CKD, 60% of HD patients, and 28% of KTRs, while it was 32% in hypertensive controls and 12% in non-hypertensive controls (p < 0.0001). Patients with HD had higher systolic pressure and a significantly greater prevalence of increased LV mass and diastolic dysfunction. In renal patients, E/e' (p = 0.025), and LV mass index (p = 0.063) were independent predictors of compromised GLS at logistic regression analysis. E/e', systolic artery pressure, and LV mass also exhibited the greatest areas under the curve on receiver operating characteristic analysis to identify a compromised GLS. Conclusions: Renal disease proved to be associated with early and subclinical impairment of LV systolic function, which persists after starting dialysis and even in spite of successful kidney transplantation. An increased E/e' resulted to be the most powerful independent predictor of abnormal GLS

    Input Clinical Parameters for Cardiac Heart Failure Characterization Using Machine Learning

    Get PDF
    Congestive Heart Failure (CHF) is a serious chronic cardiac condition that brings high risk of urgent hospi- talization and could lead to death. In this work we show how all the input clinical parameters for classifying CHF using Machine Learning can be acquired. The requested input are Blood Pres- sure, Heart Rate, Brain Natriuretic Peptide, Electrocardio- gram, Blood Oxygen Saturation, Height, Weight and Ejection Fraction. The next step will be designing a novel device and con- necting it to our Machine Learning classifier. A particular at- tention will be put to the assessment of electromagnetic compat- ibility (EMC) with other devices, taking into account that this new device will be used in many different settings (home, out- door, etc.

    Aurantoside J: a New Tetramic Acid Glycoside from Theonella swinhoei. Insights into the Antifungal Potential of Aurantosides

    Get PDF
    The chemical investigation of an Indonesian specimen of Theonella swinhoei afforded four aurantosides, one of which, aurantoside J (5), is a new compound. The structure of this metabolite, exhibiting the unprecedented N-α-glycosidic linkage between the pentose and the tetramate units, has been determined through detailed spectroscopic analysis. The four obtained aurantosides have been tested against five fungal strains (four Candida and one Fusarium) responsible of invasive infections in immuno-compromised patients. The non-cytotoxic aurantoside I (4) was the single compound to show an excellent potency against all the tested strains, thus providing valuable insights about the antifungal potential of this class of compounds and the structure-activity relationships

    Technical Design Report - TDR CYGNO-04/INITIUM

    Get PDF
    The aim of this Technical Design Report is to illustrate the technological choices foreseen to be implemented in the construction of the CYGNO-04 demonstrator, motivate them against the experiment physics goals of CYGNO-30 and demonstrate the financial sustainability of the project. CYGNO-04 represents PHASE 1 of the long term CYGNO roadmap, towards the development of large high precision tracking gaseous Time Projection Chamber (TPC) for directional Dark Matter searches and solar neutrino spectroscopy. The CYGNO project1 peculiarities reside in the optical readout of the light produced during the amplification of the primary ionization electrons in a stack of triple Gas Electron Multipliers (GEMs), thanks to the nice scintillation properties of the chosen He:CF4 gas mixture. To this aim, CYGNO is exploiting the fast progress in commercial scientific Active Pixel Sensors (APS) development for highly performing sCMOS cameras, whose high granularity and sensitivity allow to significantly boost tracking, improve particle identification and lower the energy threshold. The X-Y track project obtained from the reconstruction of the sCMOS images is combined with a PMT measurement to obtain a full 3D track reconstruction. In addition, several synergic R&Ds based on the CYGNO experimental approach are under development in the CYGNO collaboration (see Sec 2) to further enhance the light yield by means of electro luminescence after the amplification stage, to improve the tracking performances by exploiting negative ion drift operation within the INITIUM ERC Consolidator Grant, and to boost the sensitivity to O(GeV) Dark Matter masses by employing hydrogen rich target towards the development of PHASE 2 (see Sec. 1.2). While still under optimization and subject to possible significant improvements, the CYGNO experimental approach performances and capabilities demonstrated so far with prototypes allow to foresee the development of an O(30) m3 experiment by 2026 for a cost of O(10) MEUROs. A CYGNO-30 experiment would be able to give a significant contribution to the search and study of Dark Matter with masses below 10 GeV/c2 for both SI and SD coupling. In case of a Dark Matter observation claim by other experiments, the information provided by a directional detector such as CYGNO would be fundamental to positively confirm the galactic origin of the allegedly detected Dark Matter signal. CYGNO-30 could furthermore provide the first directional measurement of solar neutrinos from the pp chain, possibly extending to lower energies the Borexino measurement2. In order to reach this goal, the CYGNO project is proceeding through a staged approach. The PHASE 0 50 L detector (LIME, recently installed underground LNGS) will validate the full performances of the optical readout via APS commercial cameras and PMTs and the Montecarlo simulation of the expected backgrounds. The full CYGNO-04 demonstrator will be realized with all the technological and material choices foreseen for CYGNO-30, to demonstrate the scalability of the experimental approach and the potentialities of the large PHASE 2 detector to reach the expected physics goals. The first PHASE 1 design anticipated a 1 m3 active volume detector with two back-to-back TPCs with a central cathode and 500 mm drift length. Each 1 m2 readout area would have been composed by 9 + 9 readout modules having the LIME PHASE 0 dimensions and layout. Time (end of INITIUM project by March 2025) and current space availability at underground LNGS (only Hall F) forced the rescaling of the PHASE 1 active volume and design to a 0.4 m3, hence CYGNO-04. CYGNO-04 will keep the back-to-back double TPC layout with 500 mm drift length each, but with an 800 x 500 mm2 readout area covered by a 2 + 2 modules based on LIME design. The reduction of the detector volume has no impact on the technological objectives of PHASE 1, since the modular design with central cathode, detector materials and shieldings and auxiliary systems are independent of the total volume. The physics reach (which is a byproduct of PHASE 1 and NOT an explicit goal) will be only very partially reduced (less than a factor 2 overall) since a smaller detector volume implies also a reduced background from internal materials radioactivity. In addition, the cost reduction of CYGNO-04 of about 1⁄3 with respect to CYGNO-1 illustrated in the CDR effectively makes the overall project more financially sustainable (see CBS in the last section). In summary this document will explain: the physical motivation of the CYGNO project and the technical motivations of the downscale of the PHASE 1 to CYGNO-04, 400 liters of active volume, with respect to the demonstrator presented in the CDR; the results of R&D and the Montecarlo expectations for PHASE 0; the technical choices, procedures and the executive drawings of CYGNO-04 in the Hall F of the LNGS; safety evaluations and the interference/request to the LNGS services; Project management, WBS/WBC, WP, GANTT, ec

    Tracker Operation and Performance at the Magnet Test and Cosmic Challenge

    Get PDF
    During summer 2006 a fraction of the CMS silicon strip tracker was operated in a comprehensive slice test called the Magnet Test and Cosmic Challenge (MTCC). At the MTCC, cosmic rays detected in the muon chambers were used to trigger the readout of all CMS sub-detectors in the general data acquisition system and in the presence of the 4 T magnetic field produced by the CMS superconducting solenoid. This document describes the operation of the Tracker hardware and software prior, during and after data taking. The performance of the detector as resulting from the MTCC data analysis is also presented

    Clinical features and outcomes of elderly hospitalised patients with chronic obstructive pulmonary disease, heart failure or both

    Get PDF
    Background and objective: Chronic obstructive pulmonary disease (COPD) and heart failure (HF) mutually increase the risk of being present in the same patient, especially if older. Whether or not this coexistence may be associated with a worse prognosis is debated. Therefore, employing data derived from the REPOSI register, we evaluated the clinical features and outcomes in a population of elderly patients admitted to internal medicine wards and having COPD, HF or COPD + HF. Methods: We measured socio-demographic and anthropometric characteristics, severity and prevalence of comorbidities, clinical and laboratory features during hospitalization, mood disorders, functional independence, drug prescriptions and discharge destination. The primary study outcome was the risk of death. Results: We considered 2,343 elderly hospitalized patients (median age 81 years), of whom 1,154 (49%) had COPD, 813 (35%) HF, and 376 (16%) COPD + HF. Patients with COPD + HF had different characteristics than those with COPD or HF, such as a higher prevalence of previous hospitalizations, comorbidities (especially chronic kidney disease), higher respiratory rate at admission and number of prescribed drugs. Patients with COPD + HF (hazard ratio HR 1.74, 95% confidence intervals CI 1.16-2.61) and patients with dementia (HR 1.75, 95% CI 1.06-2.90) had a higher risk of death at one year. The Kaplan-Meier curves showed a higher mortality risk in the group of patients with COPD + HF for all causes (p = 0.010), respiratory causes (p = 0.006), cardiovascular causes (p = 0.046) and respiratory plus cardiovascular causes (p = 0.009). Conclusion: In this real-life cohort of hospitalized elderly patients, the coexistence of COPD and HF significantly worsened prognosis at one year. This finding may help to better define the care needs of this population

    Differential cross section measurements for the production of a W boson in association with jets in proton–proton collisions at √s = 7 TeV

    Get PDF
    Measurements are reported of differential cross sections for the production of a W boson, which decays into a muon and a neutrino, in association with jets, as a function of several variables, including the transverse momenta (pT) and pseudorapidities of the four leading jets, the scalar sum of jet transverse momenta (HT), and the difference in azimuthal angle between the directions of each jet and the muon. The data sample of pp collisions at a centre-of-mass energy of 7 TeV was collected with the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 fb[superscript −1]. The measured cross sections are compared to predictions from Monte Carlo generators, MadGraph + pythia and sherpa, and to next-to-leading-order calculations from BlackHat + sherpa. The differential cross sections are found to be in agreement with the predictions, apart from the pT distributions of the leading jets at high pT values, the distributions of the HT at high-HT and low jet multiplicity, and the distribution of the difference in azimuthal angle between the leading jet and the muon at low values.United States. Dept. of EnergyNational Science Foundation (U.S.)Alfred P. Sloan Foundatio
    corecore