840 research outputs found

    Super Yang-Mills on the lattice with domain wall fermions

    Get PDF
    The dynamical N=1, SU(2) Super Yang-Mills theory is studied on the lattice using a new lattice fermion regulator, domain wall fermions. This formulation even at non-zero lattice spacing does not require fine-tuning, has improved chiral properties and can produce topological zero-mode phenomena. Numerical simulations of the full theory on lattices with the topology of a torus indicate the formation of a gluino condensate which is sustained at the chiral limit. The condensate is non-zero even for small volume and small supersymmetry breaking mass where zero mode effects due to gauge fields with fractional topological charge appear to play a role.Comment: LaTeX, 35 pages, 11 eps figures. A few changes in sec. 5.3, figure 11 added. To appear in Phys. Rev.

    Clin Transl Sci

    Get PDF
    Adenosine boasts promising preclinical and clinical data supporting a vital role in modulating vascular homeostasis. Its widespread use as a diagnostic and therapeutic agent have been limited by its short half-life and complex biology, though adenosine-modulators have shown promise in improving vascular healing. Moreover, circulating adenosine has shown promise in predicting cardiovascular (CV) events. We sought to delineate whether circulating plasma adenosine levels predict CV events in patients undergoing invasive assessment for coronary artery disease. Patients undergoing invasive angiography had clinical data prospectively recorded in the Cardiovascular and Percutaneous ClInical TriALs (CAPITAL) revascularization registry and blood samples collected in the CAPITAL Biobank from which adenosine levels were quantified. Tertile-based analysis was used to assess prediction of major adverse cardiovascular events (MACE; composite of death, myocardial infarction, unplanned revascularization, and cerebrovascular accident). Secondary analyses included MACE subgroups, clinical subgroups and adenosine levels. There were 1,815 patients undergoing angiography who had blood collected with adenosine quantified in 1,323. Of those quantified, 51.0% were revascularized and 7.3% experienced MACE in 12 months of follow-up. Tertile-based analysis failed to demonstrate any stratification of MACE rates (log rank, P = 0.83), when comparing low-to-middle (hazard ratio (HR) 1.10, 95% confidence interval (CI) 0.68-1.78, P = 0.70) or low-to-high adenosine tertiles (HR 0.95, 95% CI 0.56-1.57, P = 0.84). In adjusted analysis, adenosine similarly failed to predict MACE. Finally, adenosine did not predict outcomes in patients with acute coronary syndrome nor in those revascularized or treated medically. Plasma adenosine levels do not predict subsequent CV outcomes or aid in patient risk stratification

    Acupuncture for dry eye: a randomised controlled trial protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Dry eye is usually managed by conventional medical interventions such as artificial tears, anti-inflammatory drugs and surgical treatment. However, since dry eye is one of the most frequent ophthalmologic disorders, safer and more effective methods for its treatment are necessary, especially for vulnerable patients. Acupuncture has been widely used to treat patients with dry eye. Our aim is to evaluate the effectiveness and safety of acupuncture for this condition.</p> <p>Methods/Design</p> <p>A randomised, patient-assessor blinded, sham (non-acupuncture point, shallow acupuncture) controlled study was established. Participants allocated to verum acupuncture and sham acupuncture groups will be treated three times weekly for three weeks for a total of nine sessions per participant. Seventeen points (GV23; bilateral BL2, GB4, TE23, Ex1 (Taiyang), ST1 and GB20; and left SP3, LU9, LU10 and HT8 for men, right for women) have been selected for the verum acupuncture; for the sham acupuncture, points have been selected that do not coincide with a classical acupuncture point and that are located close to the verum points, except in the case of the rim of the eye. Ocular surface disease index, tear film breakup time, the Schirmer I test, medication quantification scale and general assessment of improvement will be used as outcome variables for evaluating the effectiveness of acupuncture. Safety will also be assessed at every visit. Primary and secondary outcomes will be assessed four weeks after screening. All statistical analyses will be performed using analysis of covariance.</p> <p>Discussion</p> <p>The results of this trial will be used as a basis for clarifying the efficacy of acupuncture for dry eye.</p> <p>Trial registration</p> <p>ClinicalTrials.gov NCT00969280.</p

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  μb-1 of data as a function of transverse momentum (pT) and the transverse energy (ΣETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∼0) correlation that grows rapidly with increasing ΣETPb. A long-range “away-side” (Δϕ∼π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ΣETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ΣETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁡2Δϕ modulation for all ΣETPb ranges and particle pT

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
    corecore