41 research outputs found

    HPLC method development for the simultaneous analysis of amlodipine and valsartan in combined dosage forms and in vitro dissolution studies

    Get PDF
    A simple, rapid and reproducible HPLC method was developed for the simultaneous determination of amlodipine and valsartan in their combined dosage forms, and for drug dissolution studies. A C18 column (ODS 2, 10 μm, 200 x 4.6 mm) and a mobile phase of phosphate buffer (pH 3.6 , 0.01 mol L-1):acetonitrile: methanol (46:44:10 v/v/v) mixture were used for separation and quantification. Analyses were run at a flow-rate of 1 mL min-1 and at ambient temperature. The injection volume was 20 μL and the ultraviolet detector was set at 240 nm. Under these conditions, amlodipine and valsartan were eluted at 7.1 min and 3.4 min, respectively. Total run time was shorter than 9 min. The developed method was validated according to the literature and found to be linear within the range 0.1 - 50 μg mL-1 for amlodipine, and 0.05 - 50 μg mL-1 for valsartan. The developed method was applied successfully for quality control assay of amlodipine and valsartan in their combination drug product and in vitro dissolution studies.Desenvolveu-se método de HPLC rápido e reprodutível para a determinação simultânea de anlodipino e valsartana em suas formas de associação e para os estudos de dissolução dos fármacos. Utilizaram-se coluna C18 (ODS 2, 10 μm, 200 x 4,6 mm) e fase móvel tampão fosfato (pH 3,6, 0,01 mol L-1):acetonitrila: metanol para a separação e a quantificação. As análises foram efetuadas com velocidade de fluxo de 1 mL min-1 e à temparatura ambiente O volume de injeção foi de 20 μL e utilizou-se detector de ultravioleta a 240 nm. Sob essas condições, anlodipino e valsartana foram eluídas a 7,1 min e 3,4 min, respectivamente. O tempo total de corrida foi menor que 9 min. O método desenvolvido foi validado de acordo com a literatura e se mostrou linear na faixa de 0,1-50 μg mL-1 para anlodipino e de 0,05-50 μg mL-1 para valsartana. O método desenvolvido foi aplicado com sucesso para ensaios de controle de qualidade de associações de anlodipino e valsartana e nos estudos de dissolução in vitro

    Comparison of intestinal permeability of nebivolol hydrochloride loaded solid lipid nanoparticles with commercial nebivolol tablet

    Get PDF
    WOS: 000458080300013The oral application of drugs is the most popular route for achieving systemic effects, nevertheless, it is limited by difficulties related to physicochemical properties of the drug. Solid lipid nanoparticles (SLNs) are appealing extensive notice because of showing increased solubility and improved oral bioavailability via different mechanisms. The aim of the study is to compare and peruse the in-situ permeation of nebivolol (NBV) loaded SLN and its commercial tablet formulation used for the treatment of hypertension. For this aim Single-Pass Intestinal Perfusion (SPIP) method was used for in-situ permeation studies. NBV loaded SLNs were prepared and modified with polyethylene glycol (PEG). In order to prepare SLNs by homogenization technique, compritol, lecithin and poloxamer were chosen. Particle sizes of blank and loaded SLN were 213.4 +/- 17.5 and 264.1 +/- 18.8 nm, respectively with polydispersity index values of approximately 0.3 for each. NBV loading resulted in positive electrical charge on SLNs. The encapsulation efficiency was 98.04 +/- 0.2 %. Permeability coefficient values were tripled when NBV was incorporated in SLNs and doubled when pure NBV was given separately with a blank SLN. PEG modified SLN can be used to enhance oral absorption of NBV, and SLNs alone can be used as permeation enhancer in oral drug delivery..TUBITAK [112S292]This study was supported by TUBITAK Project No: 112S292. The authors would like to thank Novartis (Novartis Drug Co., Turkey) for providing metoprolol tartrate. The authors would also like to thank to Ege University, Faculty of Pharmacy, Pharmaceutical Sciences Research Center (FABAL) for high pressure homogenization facilities

    Calibration of the CMS hadron calorimeters using proton-proton collision data at root s=13 TeV

    Get PDF
    Methods are presented for calibrating the hadron calorimeter system of theCMSetector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities vertical bar eta vertical bar ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.Peer reviewe

    Measurement of the W gamma Production Cross Section in Proton-Proton Collisions at root s=13 TeV and Constraints on Effective Field Theory Coefficients

    Get PDF
    A fiducial cross section for W gamma production in proton-proton collisions is measured at a center-of-mass energy of 13 TeV in 137 fb(-1) of data collected using the CMS detector at the LHC. The W -> e nu and mu nu decay modes are used in a maximum-likelihood fit to the lepton-photon invariant mass distribution to extract the combined cross section. The measured cross section is compared with theoretical expectations at next-to-leading order in quantum chromodynamics. In addition, 95% confidence level intervals are reported for anomalous triple-gauge couplings within the framework of effective field theory.Peer reviewe

    Search for long-lived particles decaying to jets with displaced vertices in proton-proton collisions at root s=13 Te V

    Get PDF
    A search is presented for long-lived particles produced in pairs in proton-proton collisions at the LHC operating at a center-of-mass energy of 13 TeV. The data were collected with the CMS detector during the period from 2015 through 2018, and correspond to a total integrated luminosity of 140 fb(-1). This search targets pairs of long-lived particles with mean proper decay lengths between 0.1 and 100 mm, each of which decays into at least two quarks that hadronize to jets, resulting in a final state with two displaced vertices. No significant excess of events with two displaced vertices is observed. In the context of R-parity violating supersymmetry models, the pair production of long-lived neutralinos, gluinos, and top squarks is excluded at 95% confidence level for cross sections larger than 0.08 fb, masses between 800 and 3000 GeV, and mean proper decay lengths between 1 and 25 mm.Peer reviewe

    Search for top squark production in fully hadronic final states in proton-proton collisions at root s=13 TeV

    Get PDF
    A search for production of the supersymmetric partners of the top quark, top squarks, is presented. The search is based on proton-proton collision events containing multiple jets, no leptons, and large transverse momentum imbalance. The data were collected with the CMS detector at the CERN LHC at a center-of-mass energy of 13 TeV, and correspond to an integrated luminosity of 137 fb(-1). The targeted signal production scenarios are direct and gluino-mediated top squark production, including scenarios in which the top squark and neutralino masses are nearly degenerate. The search utilizes novel algorithms based on deep neural networks that identify hadronically decaying top quarks and W bosons, which are expected in many of the targeted signal models. No statistically significant excess of events is observed relative to the expectation from the standard model, and limits on the top squark production cross section are obtained in the context of simplified supersymmetric models for various production and decay modes. Exclusion limits as high as 1310 GeVare established at the 95% confidence level on the mass of the top squark for direct top squark production models, and as high as 2260 GeV on the mass of the gluino for gluino-mediated top squark production models. These results represent a significant improvement over the results of previous searches for supersymmetry by CMS in the same final state.Peer reviewe

    Search for dark matter particles produced in association with a Higgs boson in proton-proton collisions at √s = 13 TeV

    Get PDF
    © 2020, The Author(s). A search for dark matter (DM) particles is performed using events with a Higgs boson candidate and large missing transverse momentum. The analysis is based on proton- proton collision data at a center-of-mass energy of 13 TeV collected by the CMS experiment at the LHC in 2016, corresponding to an integrated luminosity of 35.9 fb−1. The search is performed in five Higgs boson decay channels: h → b b ¯ , γγ, τ+τ−, W+W−, and ZZ. The results from the individual channels are combined to maximize the sensitivity of the analysis. No significant excess over the expected standard model background is observed in any of the five channels or in their combination. Limits are set on DM production in the context of two simplified models. The results are also interpreted in terms of a spin-independent DM-nucleon scattering cross section and compared to those from direct-detection DM experiments. This is the first search for DM particles produced in association with a Higgs boson decaying to a pair of W or Z bosons, and the first statistical combination based on five Higgs boson decay channels. [Figure not available: see fulltext.].SCOAP

    Uv Spectrophotometric Method For Determination Of The Dissolution Profile Of Rivaroxaban

    No full text
    Rivaroxaban is an oral anticoagulant that is the first available orally active direct Factor Xa inhibitor. In this study, a UV spectrophotometric method was developed for the determination of rivaroxaban content in pharmaceutical formulations and the amount of rivaroxaban released in tablet dissolution studies. The dissolution profile of rivaroxaban was successfully determined with the validated method.WoSScopu
    corecore