457 research outputs found

    Diagnostic performance and reference values of novel biomarkers of paediatric heart failure

    Get PDF
    Objective: Biomarkers play a pivotal role in heart failure (HF) management. Reference values and insights from studies in adults cannot be extrapolated to the paediatric population due to important differences in pathophysiology and compensatory reserve. We assessed the diagnostic utility of four novel biomarkers in paediatric HF. Methods: Midregional (MR) pro-atrial natriuretic peptide (proANP), soluble ST2 (sST2), growth differentiation factor-15 (GDF-15), MR-pro-adrenomedullin (proADM) and N-terminal pro-B natriuretic peptide (NT-proBNP) were measured in 114 patients and 89 controls. HF was defined as the presence of HF symptoms and/or abnormal systolic ventricular function. Receiver-operating characteristics were plotted, and the area under the curve (AUC) was measured. This was repeated for subgroups with cardiomyopathy and congenital heart disease (CHD). Ventricular systolic function was measured by magnetic resonance or echocardiography. Reference values were calculated according to the current guidelines. Results: The AUC for diagnosing HF was 0.76 for MR-proANP (CI 0.70 to 0.84) and 0.82 for NT-proBNP (CI 0.75 to 0.88). These parameters performed similarly in the subgroups with CHD and cardiomyopathy. By contrast, MR-proADM, GDF-15 and sST2 performed poorly. When used in conjunction with NT-proBNP, no parameter added significantly to its diagnostic accuracy. NT-proBNP, MR-proANP, GDF-15 and sST2 could accurately discriminate between patients with preserved and patients with poor functional status. In a subset of patients with dilated cardiomyopathy, NT-proBNP, MR-proANP, MR-proADM and GDF-15 were associated with poor LV function. Conclusions: MR-proANP could accurately detect HF in children and adolescents. Its diagnostic performance was comparable with that of NT-proBNP, regardless of the underlying condition. Reference values are presented

    Catheter Balloon Adjustment of the Pulmonary Artery Band: Feasibility and Safety

    Get PDF
    The study aimed to assess the feasibility and safety of increasing pulmonary artery band (PAB) diameter by catheter-based PAB balloon dilation (PABBD). Eight dilations were performed between October 2006 and December 2008. Hemoclips were used to fix PABs surgically in a procedure designed to permit progressive clip dislodgment in a controlled manner. The PABBD resulted in gradual band loosening until the desired physiologic state was achieved. At time of PABBD, the patients had a mean age of 6 months (range 3–14 months) and a mean weight of 5 kg (range 2.6–7.3 kg). The median time from PAB placement until PABBD was 4.5 months (range 1–9 months). The single-balloon technique was used in seven cases (serial dilations in 5 cases) and the double-balloon technique in one case. The PABBDs were successful for all the patients, who experienced a mean saturation increase of 75–89% (P = 0.01) (mean increase of 20%), a mean PAB gradient decrease from 69 to 36 mmHg (P = 0.002) (mean decrease of 49%), and a mean band site diameter increase from 4.1 to 6.1 mm (P = 0.01) (mean increase of 45%). The only complication was transient pulmonary edema in one patient. The PABBD procedure is a feasible and safe method for increasing pulmonary blood flow in a staged manner and may eliminate the need for surgical band removal in some cases

    The Λp\bf{\Lambda p} interaction studied via femtoscopy in p + Nb reactions at sNN=3.18 GeV\mathbf{\sqrt{s_{NN}}=3.18} ~\mathrm{\bf{GeV}}

    Full text link
    We report on the first measurement of pΛp\Lambda and pppp correlations via the femtoscopy method in p+Nb reactions at sNN=3.18 GeV\mathrm{\sqrt{s_{NN}}=3.18} ~\mathrm{GeV}, studied with the High Acceptance Di-Electron Spectrometer (HADES). By comparing the experimental correlation function to model calculations, a source size for pppp pairs of r0,pp=2.02±0.01(stat)−0.12+0.11(sys) fmr_{0,pp}=2.02 \pm 0.01(\mathrm{stat})^{+0.11}_{-0.12} (\mathrm{sys}) ~\mathrm{fm} and a slightly smaller value for pΛp\Lambda of r0,Λp=1.62±0.02(stat)−0.08+0.19(sys) fmr_{0,\Lambda p}=1.62 \pm 0.02(\mathrm{stat})^{+0.19}_{-0.08}(\mathrm{sys}) ~\mathrm{fm} is extracted. Using the geometrical extent of the particle emitting region, determined experimentally with pppp correlations as reference together with a source function from a transport model, it is possible to study different sets of scattering parameters. The pΛp\Lambda correlation is proven sensitive to predicted scattering length values from chiral effective field theory. We demonstrate that the femtoscopy technique can be used as valid alternative to the analysis of scattering data to study the hyperon-nucleon interaction.Comment: 12 pages, 11 figure

    Paediatric aortic valve replacement using decellularized allografts: a multicentre update following 143 implantations and five-year mean follow-up

    Get PDF
    OBJECTIVES: Decellularized aortic homografts (DAH) were introduced in 2008 as a further option for paediatric aortic valve replacement (AVR). METHODS: Prospective, multicentre follow-up of all paediatric patients receiving DAH for AVR in 8 European centres. RESULTS: A total of 143 DAH were implanted between February 2008 and February 2023 in 137 children (106 male, 74%) with a median age of 10.8 years (interquartile range 6.6–14.6). Eighty-four (59%) had undergone previous cardiac operations and 24 (17%) had undergone previous AVR. The median implanted DAH diameter was 21 mm (interquartile range 19–23). The median operation duration was 348 min (227–439) with a median cardiopulmonary bypass time of 212 min (171–257) and a median cross-clamp time of 135 min (113– 164). After a median follow-up of 5.3 years (3.3–7.2, max. 15.2 years), the primary efficacy end-points peak gradient (median 14 mmHg, 9–28) and regurgitation (median 0.5, interquartile range 0–1, grade 0–3) showed good results but an increase over time. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 5 years were 97.8 ± 1.2/88.7 ± 3.3/99.1 ± 0.9/100 and 99.2 ± 0.8%, respectively. Freedom from death/explantation/endocarditis/bleeding/thromboembolism at 10 years were 96.3 ± 1.9/67.1 ± 8.0/93.6 ± 3.9/ 98.6 ± 1.4 and 86.9 ± 11.6%, respectively. In total, 21 DAH were explanted. Seven were replaced by a mechanical AVR, 1 Ross operation was performed and a re-do DAH was implanted in 13 patients with no redo mortality. The calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.4 years), and in the same range as for Ross patients (9.2 years) and mechanical AVR (13.0 years). CONCLUSIONS: This large-scale prospective analysis demonstrates excellent mid-term survival using DAH with adverse event rates comparable to paediatric Ross procedures.Thoracic Surger

    Search for Gravitational Wave Bursts from Six Magnetars

    Get PDF
    Soft gamma repeaters (SGRs) and anomalous X-ray pulsars (AXPs) are thought to be magnetars: neutron stars powered by extreme magnetic fields. These rare objects are characterized by repeated and sometimes spectacular gamma-ray bursts. The burst mechanism might involve crustal fractures and excitation of non-radial modes which would emit gravitational waves (GWs). We present the results of a search for GW bursts from six galactic magnetars that is sensitive to neutron star f-modes, thought to be the most efficient GW emitting oscillatory modes in compact stars. One of them, SGR 0501+4516, is likely similar to 1 kpc from Earth, an order of magnitude closer than magnetars targeted in previous GW searches. A second, AXP 1E 1547.0-5408, gave a burst with an estimated isotropic energy >10(44) erg which is comparable to the giant flares. We find no evidence of GWs associated with a sample of 1279 electromagnetic triggers from six magnetars occurring between 2006 November and 2009 June, in GW data from the LIGO, Virgo, and GEO600 detectors. Our lowest model-dependent GW emission energy upper limits for band-and time-limited white noise bursts in the detector sensitive band, and for f-mode ringdowns (at 1090 Hz), are 3.0 x 10(44)d(1)(2) erg and 1.4 x 10(47)d(1)(2) erg, respectively, where d(1) = d(0501)/1 kpc and d(0501) is the distance to SGR 0501+4516. These limits on GW emission from f-modes are an order of magnitude lower than any previous, and approach the range of electromagnetic energies seen in SGR giant flares for the first time.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyItalian Istituto Nazionale di Fisica NucleareFrench Centre National de la Recherche ScientifiqueAustralian Research CouncilCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Educacion y CienciaConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsFoundation for Fundamental Research on Matter supported by the Netherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFoundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space Administration NNH07ZDA001-GLASTCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationRussian Space AgencyRFBR 09-02-00166aIPN JPL Y503559 (Odyssey), NASA NNG06GH00G, NASA NNX07AM42G, NASA NNX08AC89G (INTEGRAL), NASA NNG06GI896, NASA NNX07AJ65G, NASA NNX08AN23G (Swift), NASA NNX07AR71G (MESSENGER), NASA NNX06AI36G, NASA NNX08AB84G, NASA NNX08AZ85G (Suzaku), NASA NNX09AU03G (Fermi)Astronom

    Sensitivity to Gravitational Waves from Compact Binary Coalescences Achieved during LIGO's Fifth and Virgo's First Science Run

    Get PDF
    We summarize the sensitivity achieved by the LIGO and Virgo gravitational wave detectors for compact binary coalescence (CBC) searches during LIGO's fifth science run and Virgo's first science run. We present noise spectral density curves for each of the four detectors that operated during these science runs which are representative of the typical performance achieved by the detectors for CBC searches. These spectra are intended for release to the public as a summary of detector performance for CBC searches during these science runs.Comment: 12 pages, 5 figure

    Gravitational Waves From Known Pulsars: Results From The Initial Detector Era

    Get PDF
    We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyAustralian Research CouncilInternational Science Linkages program of the Commonwealth of AustraliaCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Economia y CompetitividadConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsNetherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFOCUS Programme of Foundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space AdministrationOTKA of HungaryLyon Institute of Origins (LIO)National Research Foundation of KoreaIndustry CanadaProvince of Ontario through the Ministry of Economic Development and InnovationNational Science and Engineering Research Council CanadaCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationAstronom

    Implementation and testing of the first prompt search for gravitational wave transients with electromagnetic counterparts

    Get PDF
    Aims. A transient astrophysical event observed in both gravitational wave (GW) and electromagnetic (EM) channels would yield rich scientific rewards. A first program initiating EM follow-ups to possible transient GW events has been developed and exercised by the LIGO and Virgo community in association with several partners. In this paper, we describe and evaluate the methods used to promptly identify and localize GW event candidates and to request images of targeted sky locations. Methods. During two observing periods (Dec 17 2009 to Jan 8 2010 and Sep 2 to Oct 20 2010), a low-latency analysis pipeline was used to identify GW event candidates and to reconstruct maps of possible sky locations. A catalog of nearby galaxies and Milky Way globular clusters was used to select the most promising sky positions to be imaged, and this directional information was delivered to EM observatories with time lags of about thirty minutes. A Monte Carlo simulation has been used to evaluate the low-latency GW pipeline's ability to reconstruct source positions correctly. Results. For signals near the detection threshold, our low-latency algorithms often localized simulated GW burst signals to tens of square degrees, while neutron star/neutron star inspirals and neutron star/black hole inspirals were localized to a few hundred square degrees. Localization precision improves for moderately stronger signals. The correct sky location of signals well above threshold and originating from nearby galaxies may be observed with ~50% or better probability with a few pointings of wide-field telescopes.Comment: 17 pages. This version (v2) includes two tables and 1 section not included in v1. Accepted for publication in Astronomy & Astrophysic

    Swift follow-up observations of candidate gravitational-wave transient events

    Get PDF
    We present the first multi-wavelength follow-up observations of two candidate gravitational-wave (GW) transient events recorded by LIGO and Virgo in their 2009-2010 science run. The events were selected with low latency by the network of GW detectors and their candidate sky locations were observed by the Swift observatory. Image transient detection was used to analyze the collected electromagnetic data, which were found to be consistent with background. Off-line analysis of the GW data alone has also established that the selected GW events show no evidence of an astrophysical origin; one of them is consistent with background and the other one was a test, part of a "blind injection challenge". With this work we demonstrate the feasibility of rapid follow-ups of GW transients and establish the sensitivity improvement joint electromagnetic and GW observations could bring. This is a first step toward an electromagnetic follow-up program in the regime of routine detections with the advanced GW instruments expected within this decade. In that regime multi-wavelength observations will play a significant role in completing the astrophysical identification of GW sources. We present the methods and results from this first combined analysis and discuss its implications in terms of sensitivity for the present and future instruments.Comment: Submitted for publication 2012 May 25, accepted 2012 October 25, published 2012 November 21, in ApJS, 203, 28 ( http://stacks.iop.org/0067-0049/203/28 ); 14 pages, 3 figures, 6 tables; LIGO-P1100038; Science summary at http://www.ligo.org/science/Publication-S6LVSwift/index.php ; Public access area to figures, tables at https://dcc.ligo.org/cgi-bin/DocDB/ShowDocument?docid=p110003
    • 

    corecore