396 research outputs found
Quantitative assessment of biosecurity in broiler farms using Biocheck.UGent in Central Luzon, Philippines
The biosecurity status of 397 broiler farms in Central Luzon, the highest poultry meat-producing region in the Philippines, was assessed using Biocheck.Ugent. This online biosecurity assessment tool quantifies biosecurity level or compliance of surveyed farms. The system generates scores that reflect the current biosecurity status of each farm in terms of the different external and internal biosecurity measures being implemented in each farm. It was initially developed for pigs and broilers but recently is available for layers, swine, and cattle (beef, dairy, and veal).
The overall biosecurity score of broiler farms in Central Luzon was 71.2%, with average external and internal biosecurity scores of 68.5 and 77.2%, respectively. Bataan had the highest biosecurity scores (76.5%) compared with the other 6 provinces. This was also true for the external and internal biosecurity scores of the province, with mean scores of 72.1 and 80.1%, respectively. Of the 11 subcategories of external and internal biosecurity that were assessed, purchase of day-old chicks, feeds and water supply, supply of materials, cleaning and disinfection, and materials between compartments had scores higher than the global scores. Low scores were generated from transport of live animals and infrastructure and biological vectors.
The mean biosecurity score of farms with traditional/dconventional type of housing was 7.8% lower than that with tunnel vent housing. Every year as the farm gets older, there was a corresponding drop of 0.2% in the biosecurity score.
Biosecurity measures are in place in broiler farms in the country. However, there were areas with low scores which need to be prioritized to improve and upgrade the farms' biosecurity status.
To date, this is the first quantitative assessment of biosecurity in broiler farms in the Philippines. High biosecurity scores may entail greater protection from disease incursion
Magnetic field effect on the dielectric constant of glasses: Evidence of disorder within tunneling barriers
The magnetic field dependence of the low frequency dielectric constant
(H) of a structural glass a - SiO2 + xCyHz was studied from 400 mK to 50
mK and for H up to 3T. Measurement of both the real and the imaginary parts of
is used to eliminate the difficult question of keeping constant the
temperature of the sample while increasing H: a non-zero (H) dependence is
reported in the same range as that one very recently reported on multicomponent
glasses. In addition to the recently proposed explanation based on
interactions, the reported (H) is interpreted quantitatively as a
consequence of the disorder lying within the nanometric barriers of the
elementary tunneling systems of the glass.Comment: latex Bcorrige1.tex, 5 files, 4 figures, 7 pages [SPEC-S02/009
The clustering of ultra-high energy cosmic rays and their sources
The sky distribution of cosmic rays with energies above the 'GZK cutoff'
holds important clues to their origin. The AGASA data, although consistent with
isotropy, shows evidence for small-angle clustering, and it has been argued
that such clusters are aligned with BL Lacertae objects, implicating these as
sources. It has also been suggested that clusters can arise if the cosmic rays
come from the decays of very massive relic particles in the Galactic halo, due
to the expected clumping of cold dark matter. We examine these claims and show
that both are in fact not justified.Comment: 13 pages, 8 figures, version in press at Phys. Rev.
Anisotropy studies around the galactic centre at EeV energies with the Auger Observatory
Data from the Pierre Auger Observatory are analyzed to search for
anisotropies near the direction of the Galactic Centre at EeV energies. The
exposure of the surface array in this part of the sky is already significantly
larger than that of the fore-runner experiments. Our results do not support
previous findings of localized excesses in the AGASA and SUGAR data. We set an
upper bound on a point-like flux of cosmic rays arriving from the Galactic
Centre which excludes several scenarios predicting sources of EeV neutrons from
Sagittarius . Also the events detected simultaneously by the surface and
fluorescence detectors (the `hybrid' data set), which have better pointing
accuracy but are less numerous than those of the surface array alone, do not
show any significant localized excess from this direction.Comment: Matches published versio
Evidence for a mixed mass composition at the `ankle' in the cosmic-ray spectrum
We report a first measurement for ultra-high energy cosmic rays of the
correlation between the depth of shower maximum and the signal in the water
Cherenkov stations of air-showers registered simultaneously by the fluorescence
and the surface detectors of the Pierre Auger Observatory. Such a correlation
measurement is a unique feature of a hybrid air-shower observatory with
sensitivity to both the electromagnetic and muonic components. It allows an
accurate determination of the spread of primary masses in the cosmic-ray flux.
Up till now, constraints on the spread of primary masses have been dominated by
systematic uncertainties. The present correlation measurement is not affected
by systematics in the measurement of the depth of shower maximum or the signal
in the water Cherenkov stations. The analysis relies on general characteristics
of air showers and is thus robust also with respect to uncertainties in
hadronic event generators. The observed correlation in the energy range around
the `ankle' at differs significantly from
expectations for pure primary cosmic-ray compositions. A light composition made
up of proton and helium only is equally inconsistent with observations. The
data are explained well by a mixed composition including nuclei with mass . Scenarios such as the proton dip model, with almost pure compositions, are
thus disfavoured as the sole explanation of the ultrahigh-energy cosmic-ray
flux at Earth.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
Update on the correlation of the highest energy cosmic rays with nearby extragalactic matter
Data collected by the Pierre Auger Observatory through 31 August 2007 showed
evidence for anisotropy in the arrival directions of cosmic rays above the
Greisen-Zatsepin-Kuz'min energy threshold, \nobreak{eV}. The
anisotropy was measured by the fraction of arrival directions that are less
than from the position of an active galactic nucleus within 75 Mpc
(using the V\'eron-Cetty and V\'eron catalog). An updated
measurement of this fraction is reported here using the arrival directions of
cosmic rays recorded above the same energy threshold through 31 December 2009.
The number of arrival directions has increased from 27 to 69, allowing a more
precise measurement. The correlating fraction is , compared
with expected for isotropic cosmic rays. This is down from the early
estimate of . The enlarged set of arrival directions is
examined also in relation to other populations of nearby extragalactic objects:
galaxies in the 2 Microns All Sky Survey and active galactic nuclei detected in
hard X-rays by the Swift Burst Alert Telescope. A celestial region around the
position of the radiogalaxy Cen A has the largest excess of arrival directions
relative to isotropic expectations. The 2-point autocorrelation function is
shown for the enlarged set of arrival directions and compared to the isotropic
expectation.Comment: Accepted for publication in Astroparticle Physics on 31 August 201
Atmospheric effects on extensive air showers observed with the Surface Detector of the Pierre Auger Observatory
Atmospheric parameters, such as pressure (P), temperature (T) and density,
affect the development of extensive air showers initiated by energetic cosmic
rays. We have studied the impact of atmospheric variations on extensive air
showers by means of the surface detector of the Pierre Auger Observatory. The
rate of events shows a ~10% seasonal modulation and ~2% diurnal one. We find
that the observed behaviour is explained by a model including the effects
associated with the variations of pressure and density. The former affects the
longitudinal development of air showers while the latter influences the Moliere
radius and hence the lateral distribution of the shower particles. The model is
validated with full simulations of extensive air showers using atmospheric
profiles measured at the site of the Pierre Auger Observatory.Comment: 24 pages, 9 figures, accepted for publication in Astroparticle
Physic
The exposure of the hybrid detector of the Pierre Auger Observatory
The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays.
It consists of a surface array to measure secondary particles at ground level
and a fluorescence detector to measure the development of air showers in the
atmosphere above the array. The "hybrid" detection mode combines the
information from the two subsystems. We describe the determination of the
hybrid exposure for events observed by the fluorescence telescopes in
coincidence with at least one water-Cherenkov detector of the surface array. A
detailed knowledge of the time dependence of the detection operations is
crucial for an accurate evaluation of the exposure. We discuss the relevance of
monitoring data collected during operations, such as the status of the
fluorescence detector, background light and atmospheric conditions, that are
used in both simulation and reconstruction.Comment: Paper accepted by Astroparticle Physic
The Fluorescence Detector of the Pierre Auger Observatory
The Pierre Auger Observatory is a hybrid detector for ultra-high energy
cosmic rays. It combines a surface array to measure secondary particles at
ground level together with a fluorescence detector to measure the development
of air showers in the atmosphere above the array. The fluorescence detector
comprises 24 large telescopes specialized for measuring the nitrogen
fluorescence caused by charged particles of cosmic ray air showers. In this
paper we describe the components of the fluorescence detector including its
optical system, the design of the camera, the electronics, and the systems for
relative and absolute calibration. We also discuss the operation and the
monitoring of the detector. Finally, we evaluate the detector performance and
precision of shower reconstructions.Comment: 53 pages. Submitted to Nuclear Instruments and Methods in Physics
Research Section
- …