44 research outputs found
Mid-Infrared Optical Frequency Combs based on Difference Frequency Generation for Molecular Spectroscopy
Mid-infrared femtosecond optical frequency combs were produced by difference
frequency generation of the spectral components of a near-infrared comb in a
3-mm-long MgO:PPLN crystal. We observe strong pump depletion and 9.3 dB
parametric gain in the 1.5 \mu m signal, which yields powers above 500 mW (3
\mu W/mode) in the idler with spectra covering 2.8 \mu m to 3.5 \mu m.
Potential for broadband, high-resolution molecular spectroscopy is demonstrated
by absorption spectra and interferograms obtained by heterodyning two combs.Comment: 11 pages, 8 figure
Versatile silicon-waveguide supercontinuum for coherent mid-infrared spectroscopy
Infrared spectroscopy is a powerful tool for basic and applied science. The
molecular spectral fingerprints in the 3 um to 20 um region provide a means to
uniquely identify molecular structure for fundamental spectroscopy, atmospheric
chemistry, trace and hazardous gas detection, and biological microscopy. Driven
by such applications, the development of low-noise, coherent laser sources with
broad, tunable coverage is a topic of great interest. Laser frequency combs
possess a unique combination of precisely defined spectral lines and broad
bandwidth that can enable the above-mentioned applications. Here, we leverage
robust fabrication and geometrical dispersion engineering of silicon
nanophotonic waveguides for coherent frequency comb generation spanning 70 THz
in the mid-infrared (2.5 um to 6.2 um). Precise waveguide fabrication provides
significant spectral broadening and engineered spectra targeted at specific
mid-infrared bands. We use this coherent light source for dual-comb
spectroscopy at 5 um.Comment: 26 pages, 5 figure
Alu elements mediate MYB gene tandem duplication in human T-ALL
Recent studies have demonstrated that the MYB oncogene is frequently duplicated in human T cell acute lymphoblastic leukemia (T-ALL). We find that the human MYB locus is flanked by 257-bp Alu repeats and that the duplication is mediated somatically by homologous recombination between the flanking Alu elements on sister chromatids. Nested long-range PCR analysis indicated a low frequency of homologous recombination leading to MYB tandem duplication in the peripheral blood mononuclear cells of ā¼50% of healthy individuals, none of whom had a MYB duplication in the germline. We conclude that Alu-mediated MYB tandem duplication occurs at low frequency during normal thymocyte development and is clonally selected during the molecular pathogenesis of human T-ALL
Alu elements mediate MYB gene tandem duplication in human T-ALL
Recent studies have demonstrated that the MYB oncogene is frequently duplicated in human T cell acute lymphoblastic leukemia (T-ALL). We find that the human MYB locus is flanked by 257-bp Alu repeats and that the duplication is mediated somatically by homologous recombination between the flanking Alu elements on sister chromatids. Nested long-range PCR analysis indicated a low frequency of homologous recombination leading to MYB tandem duplication in the peripheral blood mononuclear cells of ā¼50% of healthy individuals, none of whom had a MYB duplication in the germline. We conclude that Alu-mediated MYB tandem duplication occurs at low frequency during normal thymocyte development and is clonally selected during the molecular pathogenesis of human T-ALL
Raman characterization of singlewalled carbon nanotubes and PMMA-nanotubes composites
The Raman spectroscopy have allowed us to perform studies on singlewalled nanotubes (SWNT's) produced by following methods: electric arc, laser ablation and solar energy. As this characterization method provides a great deal of informations, we will present a comparison between the nanotubes produced by all these processes and the influence of some synthesis parameters. By using spin casting, we have produced thin films of PMMA-SWNT's for different concentrations. Then, we have characterized these new materials by Raman spectroscopy. The aim of these investigations is to get information on the possible interactions between these two materials. In particular, we have studied the evolution of the composites films spectra as a function of the nanotubes concentration in the polymer.This work has been fully supported by the European Community through its Training and Mobility of Researcher program under network contract : NAMITECH, ERBFMRX- CT96-0067 @GlZ-MIHT) and by the tiench CNRS program : ULTIMATECH.Peer reviewe
The natural wood regime in rivers
International audienc
Alignment of the CMS tracker with LHC and cosmic ray data
Ā© CERN 2014 for the benefit of the CMS collaboration, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation and DOI.The central component of the CMS detector is the largest silicon tracker ever built. The precise alignment of this complex device is a formidable challenge, and only achievable with a significant extension of the technologies routinely used for tracking detectors in the past. This article describes the full-scale alignment procedure as it is used during LHC operations. Among the specific features of the method are the simultaneous determination of up to 200 000 alignment parameters with tracks, the measurement of individual sensor curvature parameters, the control of systematic misalignment effects, and the implementation of the whole procedure in a multi-processor environment for high execution speed. Overall, the achieved statistical accuracy on the module alignment is found to be significantly better than 10Ī¼m
Recommended from our members
Generation of Mid-Infrared Frequency Combs for Spectroscopic Applications
Mid-infrared laser sources prove to be a valuable tool in exploring a vast array of phenomena, finding their way into applications ranging from trace gas detection to X-ray generation and carbon dating. Mid-infrared frequency combs, in particular, are well-suited for many of these applications, owing to their inherent low-noise and broadband nature. Frequency comb technology is well-developed in the near-infrared as a result of immense technological development by the telecommunication industry in silica fiber and the existence of readily-available glass dopants such as ytterbium and erbium that enable oscillators at 1 and 1.5 Ī¼m. However, options become substantially more limited at longer wavelengths, as silica is no longer transparent and the components required in a mid-infrared frequency comb system (oscillators, fibers, and both fiber and free-space components) are far less technologically mature.
This thesis explores several different approaches to generating frequency comb sources in the mid-infrared region, and the development of sources used in the nonlinear processes implemented to reach these wavelengths. An optical parametric oscillator, two approaches to difference frequency generation, and nonlinear spectral broadening in chip-scale waveguides are developed, characterized, and spectroscopic potential for these techniques is demonstrated. The source used for these nonlinear processes, the erbium-doped fiber amplifier, is also studied and discussed throughout the design and optimization process. The nonlinear optical processes critical to this work are numerically modeled and used to confirm and predict experimental behavior