36 research outputs found

    Numerical Study of the Thermal Efficiency of a School Building with Complex Topology for Different Orientations

    Get PDF
    In this work a numerical model that simulates the thermal behavior of a building with complex topology and evaluates the indoor thermal and air quality, in transient conditions, is used for a school building thermal project. The program calculates the building surfaces solar radiation field, the building's temperatures, the internal environmental variables, and the occupant's comfort levels. Initially, after the numerical model is validated, the software is used to evaluate the school building's thermal response for four different orientations, either in winter or summer conditions. The work then aims to identify uncomfortable spaces in order to propose, as an example, several solutions that could be introduced for each orientation, that would improve the thermal comfort and air quality levels to which the occupants are subjected, and decrease the building's energy consumption levels. The information obtained from this study could be used to help a designer choose which thermal systems and solutions function best for a preferred school building orientation

    Higher harmonic anisotropic flow measurements of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report on the first measurement of the triangular v3v_3, quadrangular v4v_4, and pentagonal v5v_5 charged particle flow in Pb-Pb collisions at 2.76 TeV measured with the ALICE detector at the CERN Large Hadron Collider. We show that the triangular flow can be described in terms of the initial spatial anisotropy and its fluctuations, which provides strong constraints on its origin. In the most central events, where the elliptic flow v2v_2 and v3v_3 have similar magnitude, a double peaked structure in the two-particle azimuthal correlations is observed, which is often interpreted as a Mach cone response to fast partons. We show that this structure can be naturally explained from the measured anisotropic flow Fourier coefficients.Comment: 10 pages, 4 figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/387

    Urinary, Circulating, and Tissue Biomonitoring Studies Indicate Widespread Exposure to Bisphenol A

    Full text link

    Potential transmission pathways of clinically relevant fungi in indoor swimming pool facilities.

    No full text
    Possible transmission pathways of fungi in indoor swimming pool facilities were assessed through fungal counting in different areas of the facilities and typing of the collected fungal isolates. Air, water and surface samples were collected from seven different indoor swimming pool facilities. Fungal species were identified based on their internal transcribed spacer (ITS) sequences. Maximum fungal concentrations of 6.2 CFU/cm2, 1.39 CFU/100 mL, and 202 CFU/m³ were found on surfaces, in water and air, respectively. In total, 458 isolates were obtained, belonging to 111 fungal species, of which 50 species were clinically relevant. Phialophora oxyspora (13.3%) and Trichosporon dohaense (5.0%) were the most frequently isolated species and were merely detected on floors, as were the dermatophytes, Trichophyton interdigitale and T. rubrum. Penicillium spp. and Aspergillus spp. were the dominant fungi in water and air. No typical patterns of fungal concentrations along the preferential pathways of pool visitors were observed, however, sites where pool visitors converge while moving from one room (e.g. dressing room) to another (e.g. shower room) and walking barefoot displayed the highest fungal concentrations thus posing the highest risk of contamination. The dispersal of fungi on floors is most likely facilitated by the pool visitors and cleaning tools. Clinically relevant fungi, including the ones rarely identified in nature, were widely detected on floors, in water and in air, as well as on cleaning tools and flexibeams. Preventive measures such as cleaning should minimize the prevalence of clinically relevant fungi in swimming pool facilities since these potentially pose health risks to those vulnerable for infections
    corecore