167 research outputs found
A Kinematic Model for the Narrow-Line Region in NGC 4151
We present a simple kinematic model for the narrow-line region (NLR) of the
Seyfert 1 galaxy NGC 4151, based on our previous observations of extended [O
III] emission with the Space Telescope Imaging Spectrograph (STIS). The model
is similar to a biconical radial outflow model developed for the Seyfert 2
galaxy NGC 1068, except that the bicone axis is tilted much more into our line
of sight (40 degrees out of the plane of the sky instead of 5 degrees), and the
maximum space velocities are lower (750 km/s instead of 1300 km/s. We find
evidence for radial acceleration of the emission-line knots to a distance of
160 pc, followed by deceleration that approaches the systemic velocity at a
distance of 290 pc (for a distance to NGC 4151 of 13.3 Mpc). Other similarities
to the kinematics of NGC 1068 are: 1) there are a number of high-velocity
clouds that are not decelerated, suggesting that the medium responsible for the
deceleration is patchy, and 2) the bicone in NGC 4151 is at least partially
evacuated along its axis. Together, these two Seyfert galaxies provide strong
evidence for radial outflow (e.g., due to radiation and/or wind pressure) and
against gravitational motion or expansion away from the radio jets as the
principal kinematic component in the NLR.Comment: 31 pages, Latex, includes 11 figures in postscript, Figures
5a,5b,6a,6b in color, to appear in the Astronomical Journa
The Resolved Narrow Line Region in NGC4151
We present slitless spectra of the Narrow Line Region (NLR) in NGC4151 from
the Space Telescope Imaging Spectrograph (STIS) on HST, and investigate the
kinematics and physical conditions of the emission line clouds in this region.
Using medium resolution (~0.5 Angstrom) slitless spectra at two roll angles and
narrow band undispersed images, we have mapped the NLR velocity field from 1.2
kpc to within 13 pc (H_o=75 km/s/Mpc) of the nucleus. The inner biconical cloud
distribution exhibits recessional velocities relative to the nucleus to the NE
and approaching velocities to the SW of the nucleus. We find evidence for at
least two kinematic components in the NLR. One kinematic component is
characterized by Low Velocities and Low Velocity Dispersions (LVLVD clouds: |v|
< 400 km/s, and Delta_v < 130 km/s). This population extends through the NLR
and their observed kinematics may be gravitationally associated with the host
galaxy. Another component is characterized by High Velocities and High Velocity
Dispersions (HVHVD clouds: 400 130 km/s). This
set of clouds is located within 1.1 arcsec (~70pc) of the nucleus and has
radial velocities which are too high to be gravitational in origin, but show no
strong correlation between velocity or velocity dispersion and the position of
the radio knots. Outflow scenarios will be discussed as the driving mechanism
for these HVHVD clouds.Comment: 38 pages, 14 figures, accepted by ApJ. For higher resolution images
see http://www.pha.jhu.edu/~kaiser
Strain- and Adsorption-Dependent Electronic States and Transport or Localization in Graphene
The chapter generalizes results on influence of uniaxial strain and
adsorption on the electron states and charge transport or localization in
graphene with different configurations of imperfections (point defects):
resonant (neutral) adsorbed atoms either oxygen- or hydrogen-containing
molecules or functional groups, vacancies or substitutional atoms, charged
impurity atoms or molecules, and distortions. To observe electronic properties
of graphene-admolecules system, we applied electron paramagnetic resonance
technique in a broad temperature range for graphene oxides as a good basis for
understanding the electrotransport properties of other active carbons. Applied
technique allowed observation of possible metal-insulator transition and
sorption pumping effect as well as discussion of results in relation to the
granular metal model. The electronic and transport properties are calculated
within the framework of the tight-binding model along with the Kubo-Greenwood
quantum-mechanical formalism. Depending on electron density and type of the
sites, the conductivity for correlated and ordered adsorbates is found to be
enhanced in dozens of times as compared to the cases of their random
distribution. In case of the uniaxially strained graphene, the presence of
point defects counteracts against or contributes to the band-gap opening
according to their configurations. The band-gap behaviour is found to be
nonmonotonic with strain in case of a simultaneous action of defect ordering
and zigzag deformation. The amount of localized charge carriers (spins) is
found to be correlated with the content of adsorbed centres responsible for the
formation of potential barriers and, in turn, for the localization effects.
Physical and chemical states of graphene edges, especially at a uniaxial strain
along one of them, play a crucial role in electrical transport phenomena in
graphene-based materials.Comment: 16 pages, 10 figure
Regulation of Anthrax Toxin-Specific Antibody Titers by Natural Killer T Cell-Derived IL-4 and IFNγ
Activation of Natural Killer-like T cells (NKT) with the CD1d ligand α-GC leads to enhanced production of anthrax toxin protective Ag (PA)-neutralizing Abs, yet the underlying mechanism for this adjuvant effect is not known. In the current study we examined the role of Th1 and Th2 type responses in NKT-mediated enhancement of antibody responses to PA. First, the contribution of IL-4 and IFNγ to the production of PA-specific toxin-neutralizing Abs was examined. By immunizing C57Bl/6 controls IL-4−/− mice and IFNγ−/− mice and performing passive serum transfer experiments, it was observed that sera containing PA-specific IgG1, IgG2b and IgG2c neutralized toxin in vitro and conferred protection in vivo. Sera containing IgG2b and IgG2c neutralized toxin in vitro but were not sufficient for protection in vivo. Sera containing IgG1 and IgG2b neutralized toxin in vitro and conferred protection in vivo. IgG1 therefore emerged as a good correlate of protection. Next, C57Bl/6 mice were immunized with PA alone or PA plus a Th2-skewing α-GC derivative known as OCH. Neutralizing PA-specific IgG1 responses were modestly enhanced by OCH in C57Bl/6 mice. Conversely, IgG2b and IgG2c were considerably enhanced in PA/OCH-immunized IL-4−/− mice but did not confer protection. Finally, bone marrow chimeras were generated such that NKT cells were unable to express IL-4 or IFNγ. NKT-derived IL-4 was required for OCH-enhanced primary IgG1 responses but not recall responses. NKT-derived IL-4 and IFNγ also influenced primary and recall IgG2b and IgG2c titers. These data suggest targeted skewing of the Th2 response by α-GC derivatives can be exploited to optimize anthrax vaccination
Examination of the Effects of Heterogeneous Organization of RyR Clusters, Myofibrils and Mitochondria on Ca2+ Release Patterns in Cardiomyocytes
Spatio-temporal dynamics of intracellular calcium, [Ca2+]i, regulate the contractile function of cardiac muscle cells. Measuring [Ca2+]i flux is central to the study of mechanisms that underlie both normal cardiac function and calcium-dependent etiologies in heart disease. However, current imaging techniques are limited in the spatial resolution to which changes in [Ca2+]i can be detected. Using spatial point process statistics techniques we developed a novel method to simulate the spatial distribution of RyR clusters, which act as the major mediators of contractile Ca2+ release, upon a physiologically-realistic cellular landscape composed of tightly-packed mitochondria and myofibrils.We applied this method to computationally combine confocal-scale (~ 200 nm) data of RyR clusters with 3D electron microscopy data (~ 30 nm) of myofibrils and mitochondria, both collected from adult rat left ventricular myocytes. Using this hybrid-scale spatial model, we simulated reaction-diffusion of [Ca2+]i during the rising phase of the transient (first 30 ms after initiation). At 30 ms, the average peak of the simulated [Ca2+]i transient and of the simulated fluorescence intensity signal, F/F0, reached values similar to that found in the literature ([Ca2+]i 1 μM; F/F0 5.5). However, our model predicted the variation in [Ca2+]i to be between 0.3 and 12.7 μM (~3 to 100 fold from resting value of 0.1 μM) and the corresponding F/F0 signal ranging from 3 to 9.5. We demonstrate in this study that: (i) heterogeneities in the [Ca2+]i transient are due not only to heterogeneous distribution and clustering of mitochondria; (ii) but also to heterogeneous local densities of RyR clusters. Further, we show that: (iii) these structureinduced heterogeneities in [Ca2+]i can appear in line scan data. Finally, using our unique method for generating RyR cluster distributions, we demonstrate the robustness in the [Ca2+]i transient to differences in RyR cluster distributions measured between rat and human cardiomyocytes
Integrative Genomic Analyses Identify BRF2 as a Novel Lineage-Specific Oncogene in Lung Squamous Cell Carcinoma
William Lockwood and colleagues show that the focal amplification of a gene, BRF2, on Chromosome 8p12 plays a key role in squamous cell carcinoma of the lung
Epidural Interventions in the Management of Chronic Spinal Pain: American Society of Interventional Pain Physicians (ASIPP) Comprehensive Evidence-Based Guidelines.
BACKGROUND: Chronic spinal pain is the most prevalent chronic disease with employment of multiple modes of interventional techniques including epidural interventions. Multiple randomized controlled trials (RCTs), observational studies, systematic reviews, and guidelines have been published. The recent review of the utilization patterns and expenditures show that there has been a decline in utilization of epidural injections with decrease in inflation adjusted costs from 2009 to 2018. The American Society of Interventional Pain Physicians (ASIPP) published guidelines for interventional techniques in 2013, and guidelines for facet joint interventions in 2020. Consequently, these guidelines have been prepared to update previously existing guidelines.
OBJECTIVE: To provide evidence-based guidance in performing therapeutic epidural procedures, including caudal, interlaminar in lumbar, cervical, and thoracic spinal regions, transforaminal in lumbar spine, and percutaneous adhesiolysis in the lumbar spine.
METHODS: The methodology utilized included the development of objective and key questions with utilization of trustworthy standards. The literature pertaining to all aspects of epidural interventions was viewed with best evidence synthesis of available literature and recommendations were provided.
RESULTS: In preparation of the guidelines, extensive literature review was performed. In addition to review of multiple manuscripts in reference to utilization, expenditures, anatomical and pathophysiological considerations, pharmacological and harmful effects of drugs and procedures, for evidence synthesis we have included 47 systematic reviews and 43 RCTs covering all epidural interventions to meet the objectives.The evidence recommendations are as follows: Disc herniation: Based on relevant, high-quality fluoroscopically guided epidural injections, with or without steroids, and results of previous systematic reviews, the evidence is Level I for caudal epidural injections, lumbar interlaminar epidural injections, lumbar transforaminal epidural injections, and cervical interlaminar epidural injections with strong recommendation for long-term effectiveness.The evidence for percutaneous adhesiolysis in managing disc herniation based on one high-quality, placebo-controlled RCT is Level II with moderate to strong recommendation for long-term improvement in patients nonresponsive to conservative management and fluoroscopically guided epidural injections. For thoracic disc herniation, based on one relevant, high-quality RCT of thoracic epidural with fluoroscopic guidance, with or without steroids, the evidence is Level II with moderate to strong recommendation for long-term effectiveness.Spinal stenosis: The evidence based on one high-quality RCT in each category the evidence is Level III to II for fluoroscopically guided caudal epidural injections with moderate to strong recommendation and Level II for fluoroscopically guided lumbar and cervical interlaminar epidural injections with moderate to strong recommendation for long-term effectiveness.The evidence for lumbar transforaminal epidural injections is Level IV to III with moderate recommendation with fluoroscopically guided lumbar transforaminal epidural injections for long-term improvement. The evidence for percutaneous adhesiolysis in lumbar stenosis based on relevant, moderate to high quality RCTs, observational studies, and systematic reviews is Level II with moderate to strong recommendation for long-term improvement after failure of conservative management and fluoroscopically guided epidural injections. Axial discogenic pain: The evidence for axial discogenic pain without facet joint pain or sacroiliac joint pain in the lumbar and cervical spine with fluoroscopically guided caudal, lumbar and cervical interlaminar epidural injections, based on one relevant high quality RCT in each category is Level II with moderate to strong recommendation for long-term improvement, with or without steroids. Post-surgery syndrome: The evidence for lumbar and cervical post-surgery syndrome based on one relevant, high-quality RCT with fluoroscopic guidance for caudal and cervical interlaminar epidural injections, with or without steroids, is Level II with moderate to strong recommendation for long-term improvement. For percutaneous adhesiolysis, based on multiple moderate to high-quality RCTs and systematic reviews, the evidence is Level I with strong recommendation for long-term improvement after failure of conservative management and fluoroscopically guided epidural injections.
LIMITATIONS: The limitations of these guidelines include a continued paucity of high-quality studies for some techniques and various conditions including spinal stenosis, post-surgery syndrome, and discogenic pain.
CONCLUSIONS: These epidural intervention guidelines including percutaneous adhesiolysis were prepared with a comprehensive review of the literature with methodologic quality assessment and determination of level of evidence with strength of recommendations
Recommended from our members
The tenth data release of the Sloan digital sky survey: First spectroscopic data from the SDSS-iii apache point observatory galactic evolution experiment
The Sloan Digital Sky Survey (SDSS) has been in operation since 2000 April. This paper presents the tenth public data release (DR10) from its current incarnation, SDSS-III. This data release includes the first spectroscopic data from the Apache Point Observatory Galaxy Evolution Experiment (APOGEE), along with spectroscopic data from the Baryon Oscillation Spectroscopic Survey (BOSS) taken through 2012 July. The APOGEE instrument is a near-infrared R ~ 22,500 300-fiber spectrograph covering 1:514-1:696 μm. The APOGEE survey is studying the chemical abundances and radial velocities of roughly 100,000 red giant star candidates in the bulge, bar, disk, and halo of the Milky Way. DR10 includes 178,397 spectra of 57,454 stars, each typically observed three or more times, from APOGEE. Derived quantities from these spectra (radial velocities, effective temperatures, surface gravities, and metallicities) are also included.
DR10 also roughly doubles the number of BOSS spectra over those included in the ninth data release. DR10 includes a total of 1,507,954 BOSS spectra, comprising 927,844 galaxy spectra; 182,009 quasar spectra; and 159,327 stellar spectra, selected over 6373.2 deg2.This is an author-created, un-copyedited version of an article accepted for publication in The Astrophysical Journal Supplement Series. The publisher is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0067-0049/211/2/17. The accepted version will be under embargo until the 18th March 2015
Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.
BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700
CMS physics technical design report : Addendum on high density QCD with heavy ions
Peer reviewe
- …