41 research outputs found

    Risk of Major Complications From Coronary Angioplasty Performed Immediately After Diagnostic Coronary Angiography: Results From the Registry of the Society for Cardiac Angiography and Interventions

    Get PDF
    AbstractObjectives. This study was designed to determine the risk of performing percutaneous transluminal coronary angioplasty (PTCA) at the time of diagnostic catheterization (“combined procedures”).Background. Health care providers are under increasing pressure to combine diagnostic and interventional coronary procedures to reduce costs. However, the risk associated with combined procedures has not been rigorously assessed.Methods. A multicenter cohort study of 35,700 patients undergoing elective PTCA from 1992 through 1995 was performed to determine the risk of major complications (myocardial infarction, emergency coronary artery bypass graft surgery or death) from combined relative to staged procedures (i.e., performing PTCA at a session subsequent to diagnostic catheterization).Results. The risks of major complications from combined and staged procedures were 2.0% and 1.6%, respectively (unadjusted odds ratio [OR] 1.28, 95% confidence interval [CI] 1.05 to 1.57). After adjusting for clinical and angiographic differences and clustering by laboratory, the risk from combined procedures was not significantly elevated (multivariable OR 1.18, 95% CI 0.89 to 1.55). However, several subgroups of patients did have an increased risk from combined procedures: patients with multivessel disease (multivariable OR 1.64, 95% CI 1.13 to 2.39); women (multivariable OR 1.64, 95% CI 1.05 to 2.55); patients >65 years old (multivariable OR 1.40, 95% CI 1.02 to 1.93); and patients undergoing multilesion PTCA (multivariable OR 1.53, 95% CI 1.06 to 2.21). The risk of combined relative to staged procedures decreased over the 4-year period (multivariable p = 0.029).Conclusions. Combining PTCA with diagnostic catheterization appears to be safe in many patients. However, several subgroups of patients may be at increased risk. Careful patient selection will most likely remain critical to ensuring the safety of combined procedures.(J Am Coll Cardiol 1997;30:193–200

    A contemporary overview of percutaneous coronary interventions The American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR)

    Get PDF
    AbstractObjectivesThe American College of Cardiology (ACC) established the National Cardiovascular Data Registry (ACC–NCDR) to provide a uniform and comprehensive database for analysis of cardiovascular procedures across the country. The initial focus has been the high-volume, high-profile procedures of diagnostic cardiac catheterization and percutaneous coronary intervention (PCI).BackgroundSeveral large-scale multicenter efforts have evaluated diagnostic catheterization and PCI, but these have been limited by lack of standard definitions and relatively nonuniform data collection and reporting methods.MethodsBoth clinical and procedural data, and adverse events occurring up to hospital discharge, were collected and reported according to uniform guidelines using a standard set of 143 data elements. Datasets were transmitted quarterly to a central facility for quality-control screening, storage and analysis. This report is based on PCI data collected from January 1, 1998, through September 30, 2000.ResultsA total of 139 hospitals submitted data on 146,907 PCI procedures. Of these, 32% (46,615 procedures) were excluded because data did not pass quality-control screening. The remaining 100,292 procedures (68%) were included in the analysis set. Average age was 64 ± 12 years; 34% were women, 26% had diabetes mellitus, 29% had histories of prior myocardial infarction (MI), 32% had prior PCI and 19% had prior coronary bypass surgery. In 10% the indication for PCI was acute MI ≤6 h from onset, while in 52% it was class II to IV or unstable angina. Only 5% of procedures did not have a class I indication by ACC criteria, but this varied by hospital from a low of 0 to a high of 38%. A coronary stent was placed in 77% of procedures, but this varied by hospital from a low of 0 to a high of 97%. The frequencies of in-hospital Q-wave MI, coronary artery bypass graft surgery and death were 0.4%, 1.9% and 1.4%, respectively. Mortality varied by hospital from a low of 0 to a high of 4.2%.ConclusionsThis report presents the first data collected and analyzed by the ACC–NCDR. It portrays a contemporary overview of coronary interventional practices and outcomes, using uniform data collection and reporting standards. These data reconfirm overall acceptable results that are consistent with other reported data, but also confirm large variations between individual institutions

    Development of a risk adjustment mortality model using the American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR) experience: 1998–2000

    Get PDF
    AbstractObjectivesWe sought to develop and evaluate a risk adjustment model for in-hospital mortality following percutaneous coronary intervention (PCI) procedures using data from a large, multi-center registry.BackgroundThe 1998–2000 American College of Cardiology–National Cardiovascular Data Registry (ACC–NCDR) dataset was used to overcome limitations of prior risk-adjustment analyses.MethodsData on 100,253 PCI procedures collected at the ACC–NCDR between January 1, 1998, and September 30, 2000, were analyzed. A training set/test set approach was used. Separate models were developed for presentation with and without acute myocardial infarction (MI) within 24 h.ResultsFactors associated with increased risk of PCI mortality (with odds ratios in parentheses) included cardiogenic shock (8.49), increasing age (2.61 to 11.25), salvage (13.38) urgent (1.78) or emergent PCI (5.75), pre-procedure intra-aortic balloon pump insertion (1.68), decreasing left ventricular ejection fraction (0.87 to 3.93), presentation with acute MI (1.31), diabetes (1.41), renal failure (3.04), chronic lung disease (1.33); treatment approaches including thrombolytic therapy (1.39) and non-stent devices (1.64); and lesion characteristics including left main (2.04), proximal left anterior descending disease (1.97) and Society for Cardiac Angiography and Interventions lesion classification (1.64 to 2.11). Overall, excellent discrimination was achieved (C-index = 0.89) and application of the model to high-risk patient groups demonstrated C-indexes exceeding 0.80. Patient factors were more predictive in the MI model, while lesion and procedural factors were more predictive in the analysis of non-MI patients.ConclusionsA risk adjustment model for in-hospital mortality after PCI was successfully developed using a contemporary multi-center registry. This model is an important tool for valid comparison of in-hospital mortality after PCI

    The Evolution of Gene Expression QTL in Saccharomyces cerevisiae

    Get PDF
    Understanding the evolutionary forces that influence patterns of gene expression variation will provide insights into the mechanisms of evolutionary change and the molecular basis of phenotypic diversity. To date, studies of gene expression evolution have primarily been made by analyzing how gene expression levels vary within and between species. However, the fundamental unit of heritable variation in transcript abundance is the underlying regulatory allele, and as a result it is necessary to understand gene expression evolution at the level of DNA sequence variation. Here we describe the evolutionary forces shaping patterns of genetic variation for 1206 cis-regulatory QTL identified in a cross between two divergent strains of Saccharomyces cerevisiae. We demonstrate that purifying selection against mildly deleterious alleles is the dominant force governing cis-regulatory evolution in S. cerevisiae and estimate the strength of selection. We also find that essential genes and genes with larger codon bias are subject to slightly stronger cis-regulatory constraint and that positive selection has played a role in the evolution of major trans-acting QTL

    Gaia Early Data Release 3: Structure and properties of the Magellanic Clouds

    Get PDF
    We compare the Gaia DR2 and Gaia EDR3 performances in the study of the Magellanic Clouds and show the clear improvements in precision and accuracy in the new release. We also show that the systematics still present in the data make the determination of the 3D geometry of the LMC a difficult endeavour; this is at the very limit of the usefulness of the Gaia EDR3 astrometry, but it may become feasible with the use of additional external data. We derive radial and tangential velocity maps and global profiles for the LMC for the several subsamples we defined. To our knowledge, this is the first time that the two planar components of the ordered and random motions are derived for multiple stellar evolutionary phases in a galactic disc outside the Milky Way, showing the differences between younger and older phases. We also analyse the spatial structure and motions in the central region, the bar, and the disc, providing new insights into features and kinematics. Finally, we show that the Gaia EDR3 data allows clearly resolving the Magellanic Bridge, and we trace the density and velocity flow of the stars from the SMC towards the LMC not only globally, but also separately for young and evolved populations. This allows us to confirm an evolved population in the Bridge that is slightly shift from the younger population. Additionally, we were able to study the outskirts of both Magellanic Clouds, in which we detected some well-known features and indications of new ones

    The Gaia mission

    Get PDF
    Gaia is a cornerstone mission in the science programme of the EuropeanSpace Agency (ESA). The spacecraft construction was approved in 2006, following a study in which the original interferometric concept was changed to a direct-imaging approach. Both the spacecraft and the payload were built by European industry. The involvement of the scientific community focusses on data processing for which the international Gaia Data Processing and Analysis Consortium (DPAC) was selected in 2007. Gaia was launched on 19 December 2013 and arrived at its operating point, the second Lagrange point of the Sun-Earth-Moon system, a few weeks later. The commissioning of the spacecraft and payload was completed on 19 July 2014. The nominal five-year mission started with four weeks of special, ecliptic-pole scanning and subsequently transferred into full-sky scanning mode. We recall the scientific goals of Gaia and give a description of the as-built spacecraft that is currently (mid-2016) being operated to achieve these goals. We pay special attention to the payload module, the performance of which is closely related to the scientific performance of the mission. We provide a summary of the commissioning activities and findings, followed by a description of the routine operational mode. We summarise scientific performance estimates on the basis of in-orbit operations. Several intermediate Gaia data releases are planned and the data can be retrieved from the Gaia Archive, which is available through the Gaia home page. http://www.cosmos.esa.int/gai

    Editor's Pick: Protecting The Heart in Cancer Patients: The Role of Cardio-Oncology

    No full text
    Cardiac disease often impacts cancer therapy, from direct toxicity of cancer therapeutic agents to the coronary endothelium, the myocardium, heart valves, and other structures. This has spawned the development of cardio-oncology programmes, emphasising collaboration between oncologists and cardio-oncologists in order to develop cardiologists with expertise in understanding the impact of various cancer regimens on the heart and developing programmes to manage or prevent heart damage. Cardiac disease and cancer both become more common as people age, as such cardiac disease, including coronary disease, should be screened for and risk factors treated when possible. Cancer-caused cardiac damage is much more responsive to therapy if treated early, so protocols for monitoring heart function to identify early injury need to be established and followed. Newer measures of ventricular function can identify heart injury before a reduction in ejection fraction to permit early initiation of therapy, and protocols to utilise these measures need to be incorporated into routine surveillance. Research is underway to evaluate regimens for cardiac protection prior to the cancer therapy, but at present, the data do not permit broad recommendations

    Reply

    No full text
    corecore