672 research outputs found

    Single-Atom Gating of Quantum State Superpositions

    Full text link
    The ultimate miniaturization of electronic devices will likely require local and coherent control of single electronic wavefunctions. Wavefunctions exist within both physical real space and an abstract state space with a simple geometric interpretation: this state space--or Hilbert space--is spanned by mutually orthogonal state vectors corresponding to the quantized degrees of freedom of the real-space system. Measurement of superpositions is akin to accessing the direction of a vector in Hilbert space, determining an angle of rotation equivalent to quantum phase. Here we show that an individual atom inside a designed quantum corral can control this angle, producing arbitrary coherent superpositions of spatial quantum states. Using scanning tunnelling microscopy and nanostructures assembled atom-by-atom we demonstrate how single spins and quantum mirages can be harnessed to image the superposition of two electronic states. We also present a straightforward method to determine the atom path enacting phase rotations between any desired state vectors. A single atom thus becomes a real space handle for an abstract Hilbert space, providing a simple technique for coherent quantum state manipulation at the spatial limit of condensed matter.Comment: Published online 6 April 2008 in Nature Physics; 17 page manuscript (including 4 figures) + 3 page supplement (including 2 figures); supplementary movies available at http://mota.stanford.ed

    Second St. Gallen European Organisation for Research and Treatment of Cancer Gastrointestinal Cancer Conference: consensus recommendations on controversial issues in the primary treatment of rectal cancer

    Get PDF
    Primary treatment of rectal cancer was the focus of the second St. Gallen European Organisation for Research and Treatment of Cancer (EORTC) Gastrointestinal Cancer Conference. In the context of the conference, a multidisciplinary international expert panel discussed and voted on controversial issues which could not be easily answered using published evidence. Main topics included optimal pretherapeutic imaging, indication and type of neoadjuvant treatment, and the treatment strategies in advanced tumours. Here we report the key recommendations and summarise the related evidence. The treatment strategy for localised rectal cancer varies from local excision in early tumours to neoadjuvant radiochemotherapy (RCT) in combination with extended surgery in locally advanced disease. Optimal pretherapeutic staging is a key to any treatment decision. The panel recommended magnetic resonance imaging (MRI) or MRI + endoscopic ultrasonography (EUS) as mandatory staging modalities, except for early T1 cancers with an option for local excision, where EUS in addition to MRI was considered to be most important because of its superior near-field resolution. Primary surgery with total mesorectal excision was recommended by most panellists for some early tumours with limited risk of recurrence (i.e. cT1-2 or cT3a N0 with clear mesorectal fascia on MRI and clearly above the levator muscles), whereas all other stages were considered for multimodal treatment. The consensus panel recommended long-course RCT over short-course radiotherapy for most clinical situations where neoadjuvant treatment is indicated, with the exception of T3a/b N0 tumours where short-course radiotherapy or even no neoadjuvant therapy were regarded to be an option. In patients with potentially resectable tumours and synchronous liver metastases, most panel members did not see an indication to start with classical fluoropyrimidine-based RCT but rather favoured preoperative short-course radiotherapy with systemic combination chemotherapy or alternatively a liver-first resection approach in resectable metastases, which both allow optimal systemic therapy for the metastatic disease. In general, proper patient selection and discussion in an experienced multidisciplinary team was considered as crucial component of care

    Are ICD-10 codes appropriate for performance assessment in asthma and COPD in general practice? Results of a cross sectional observational study

    Get PDF
    BACKGROUND: The increasing prevalence and impact of obstructive lung diseases and new insights, reflected in clinical guidelines, have led to concerns about the diagnosis and therapy of asthma and COPD in primary care. In Germany diagnoses written in medical records are used for reimbursement, which may influence physicians' documentation behaviour. For that reason it is unclear to what respect ICD-10 codes reflect the real problems of the patients in general practice. The aim of this study was to assess the appropriateness of the recorded diagnoses and to determine what diagnostic information is used to guide medical treatment. METHODS: All patients with lower airway symptoms (n = 857) who had attended six general practices between January and June 2003 were included into this cross sectional observational study. Patients were selected from the computerised medical record systems, focusing on ICD-10-codes concerning lower airway diseases (J20-J22, J40-J47, J98 and R05). The performed diagnostic procedures and actual medication for each identified patient were extracted manually. Then we examined the associations between recorded diagnoses, diagnostic procedures and prescribed treatment for asthma and COPD in general practice. RESULTS: Spirometry was used in 30% of the patients with a recorded diagnosis of asthma and in 58% of the patients with a recorded diagnosis of COPD. Logistic regression analysis showed an improved use of spirometry when inhaled corticosteroids were prescribed for asthma (OR = 5.2; CI 2.9–9.2) or COPD (OR = 4.7; CI 2.0–10.6). Spirometry was also used more often when sympathomimetics were prescribed (asthma: OR = 2.3; CI 1.2–4.2; COPD: OR = 4.1; CI 1.8–9.4). CONCLUSIONS: This study revealed that spirometry was used more often when corticosteroids or sympathomimetics were prescribed. The findings suggest that treatment was based on diagnostic test results rather than on recorded diagnoses. The documented ICD-10 codes may not always reflect the real status of the patients. Thus medical care for asthma and COPD in general practice may be better than initially found on the basis of recorded diagnoses, although further improvement of practice patterns in asthma and COPD is still necessary

    Volumetry of [11C]-methionine PET uptake and MRI contrast enhancement in patients with recurrent glioblastoma multiforme

    Get PDF
    We investigated the relationship between three-dimensional volumetric data of the metabolically active tumour volume assessed using [(11)C]-methionine positron emission tomography (MET-PET) and the area of gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) enhancement assessed using magnetic resonance imaging (MRI) in patients with recurrent glioblastoma (GBM).MET-PET and contrast-enhanced MRI with Gd-DTPA were performed in 12 uniformly pretreated patients with recurrent GBM. To calculate the volumes in cubic centimetres, a threshold-based volume-of-interest (VOI) analysis of the metabolically active tumour volume (MET uptake indexes of > or = 1.3 and > or = 1.5) and of the area of Gd-DTPA enhancement was performed after coregistration of all images.In all patients, the metabolically active tumour volume as shown using a MET uptake index of > or = 1.3 was larger than the volume of Gd-DTPA enhancement (30.2 + or - 22.4 vs. 13.7 + or - 10.6 cm(3); p = 0.04). Metabolically active tumour volumes as shown using MET uptake indexes of > or =1.3 and > or = 1.5 and the volumes of Gd-DTPA enhancement showed a positive correlation (r = 0.76, p = 0.003, for an index of > or =1.3, and r = 0.74, p = 0.005, for an index of > or =1.5).The present data suggest that in patients with recurrent GBM the metabolically active tumour volume may be substantially underestimated by Gd-DTPA enhancement. The findings support the notion that complementary information derived from MET uptake and Gd-DTPA enhancement may be helpful in developing individualized, patient-tailored therapy strategies in patients with recurrent GBM

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter

    Compressed representation of a partially defined integer function over multiple arguments

    Get PDF
    In OLAP (OnLine Analitical Processing) data are analysed in an n-dimensional cube. The cube may be represented as a partially defined function over n arguments. Considering that often the function is not defined everywhere, we ask: is there a known way of representing the function or the points in which it is defined, in a more compact manner than the trivial one
    corecore